Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (48)
- Zeitschriftenartikel (36)
- Vortrag (34)
- Posterpräsentation (19)
- Buchkapitel (6)
- Beitrag zu einem Sammelband (2)
- Sonstiges (1)
Sprache
- Englisch (107)
- Deutsch (38)
- Mehrsprachig (1)
Schlagworte
- Fire (15)
- LNG (7)
- Sloshing (7)
- LH2 (5)
- Vessels (5)
- MLI (4)
- Pressure vessel (4)
- Road tankers (4)
- Tanker (4)
- Turning maneuvers (4)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (34)
Using plastic jerrycans or plastic containers, dangerous goods are transported as air freight in commercial aircrafts. Liquids or gases can escape by leakage or permeation effects from these plastic containers. The German Federal Institute for Materials Research and Testing (BAM) conducted prior research which showed that the lower explosion limit can be reached when transporting dangerous goods in sea-freight containers under normal transportation situations. The presented study is motivated based on these findings. The research objective of this study is to analyze the transportation situation of dangerous goods in cargo compartments of commercial airplanes. The scope of this paper is to present the experimental method used for validating a numerical model for CFD (Computational Fluid Dynamics) simulations and to present some simulation results of the mass transport of dangerous goods in the cargo compartment.
The velocity profiles and the mass transport is calculated using numerical simulations and measured by Laser-Doppler-Anemometry (LDA) experiments. The mock-up is a generic model of a wide-body aircraft lower deck cargo compartment in a 1: 10 scale. Geometry, air exchange rates and inlet as well as outlet flow conditions in the cargo compartment are modeled using realistic boundary conditions. The commercial CFD (Computational Fluid Dynamics) code ANSYS CFX 14 is used for numerical flow simulations applying RANS (Reynolds-Averaged-Navier-Stokes) equations and turbulence models. The turbulence models studied are the renormalization group k-e-model (RNG), the BSL-Reynolds-Stress model (BSL) and the SST-k-co-model by Menter (SST).
The flow measurement with LDA in the mock-up of a cargo compartment proves to be a feasible method for producing data to validate CFD simulations. Qualitative evaluation of the results shows a good overall agreement between numerical and experimental results. The experimental validation indicates that the implemented CFD model is capable of reproducing the flow situation in the model mock-up
A new tank design for Hazmat
(2016)
Initial studies have shown pre-deformed honeycomb structure
pressure vessels to have comparable burst pressure to straight steel vessels.
It was shown that honeycomp structured tanks have a higher energy absorption than straight steel tanks.
Future studies will investigate optimization of the deformed plate, to determine if increased payloads or a reduced wall thickness can be achieved.
The outputs from a simplified mathematical designed to simulate the liquid cargo-vehicle interaction during an emergency braking maneuver, have been compared with full scale data regarding the sloshing pressure on one of the vehicle chambers. While the specific dimensions and fill level of the fluid within the chamber in the full scale testing, have been considered for the simulation model, the vehicle has been simplified to a straight truck instead of an articulated truck. Nevertheless, the pressure within the chamber is realistically modelled, concerning the maximum and minimum pressures attained, with differences lower than 10% between the simulation and the experimental data. Consequently, these results suggest that the articulation pertaining to the articulated vehicle, does not affect in a significant manner the maximum and minimum values of the pressure within the chamber. A nonlinear model for the suspension, however, could improve the model performance. On the other hand, simulation results suggest that the effect of sloshing could cause a loss of braking efficiency on the order of 7%, when such performance is measured in terms of the stopping time.
Pressurisation of full-containment pressure vessels in fire is known to be driven by thermal stratification. The predominant mode of heat transfer to the contents (convection from the shell to the liquid phase) results in formation of „hot“ boundary layers. Sub-cooled boiling may also be present. The warm layer rises to the surface through buoyancy and bubble flow, increasing the surface of the liquid above that of the bulk temperature, and hence driving a pressure rise.
For reliable prediction of the complex effects governing vessel pressurization a three-dimensional numerical model is required. Work is being undertaken on such a model by other institutions in cooperation with this project.
Simplified cargo-vehicle interaction: linear pendulum, rigid multibody linear dynamics, straight, instead of articulated vehicle.
Realistic results about the pressure developed on the sensor, with differences lower than 10% between the simulation and the experimental data.
Sloshing could affect the braking efficiency in 7%, approximately, corresponds with other sources.
The arrangement of the measuring sensors allowed the
capture of air flow induced temperatures and material
temperatures on various points of the cylinder body. Four
significant temperature levels could be observed: Inside the cylinder (far from the wall, close to the wall), inside the aluminium liner and outer surface. Figure 5 shows the temperature distribution after a regular filling process with a filling time of ten minutes. The temperature sensors T1 - T9 are marked with different colors. The corresponding measurement points are shown in Figure 4. Due to the high thermal conductivity of the aluminum liner the induced temperature peaks are quickly derived. A flow-induced exceeding of the maximum approval temperature is not expected. Regarding the safety assessement the results show that the pressure and temperature profilesmustbe taken into account.
The application of lightweight materials for tanks for transportation appears promising. Besides saving weight and therefore transportation costs, new complex geometries that depart from common cylindrical shapes of steel tanks can be manufactured. For transportation of dangerous goods, fire and explosion safety must be maintained to prevent accidents with serious consequences. In this work the fire behavior of lightweight tanks made from glass fiber reinforced plastics (GFRP) with complex geometries is investigated. Pretests on intermediate scale GFRP plates are conducted to identify suitable fire protection systems and surface treatments for composite tanks. The fire resistance is shown to be improved by addition of fire protective coatings and integrated layers. Finally, a complex rectangular GFRP tank with a holding capacity of 1100 liters is fire protected with an intumescent fire coating. The tank is filled up to 80 % with water and burned under an engulfing fully developed fire. It was shown that the intumescent layer could expand before the decomposition of the resin occurred. Furthermore, the adhesion between tank surface and coating was maintained. The structure could withstand a fire for more than 20 min.