The vessel wall response shows a good agreement between the numerical predictions of and experimental data using the limit load approach. Further work is continuing to understand the thermohydraulic response and the boundary conditions for material modelling. As shown in figure 2 there was one BLEVE of a bare tank containing a PRV, highlighting the risk of serious consequences if models are inaccurate. The behavior of partly coated tanks were similar to the bare tank.
The results are based on data1. Figure 3 displays temperatures of the tank wall and of the gas phase over testing time. It can be seen that a complete coating strongly delayed the heating of tank wall and gas phase, whereas the partly coated tanks only had a minor influence on temperature development. There was no significant difference between a half coated and a thirdly coated tank measurable. Figure 4 shows the internal pressure of tanks over testing time. Only the fully coated tank enabled a low pressure over 90 min testing time. Hence, a complete coating is necessary to guarantee the fire safety of hazmat tanks and a partly coating is not sufficient.
A simplified model, based upon physical principles, is proposed the simulate the effect of sloshing on the pressure developed in the tanker chambers. The model has been validated in good extent, with experimental data from full scale testing. The characteristic that mostly affects the pressure developed with the chambers of the tanker is the length of the chamber. While a reduction in this property could decrease the pressure developed within a given chamber, the analysis should take into account an overall approach, as a shortening of the individual chambers would influence the number of chambers necessary to carry a certain amount of product. Consequently, the resulting model could be used to study different effects of the sloshing cargo on the carrying vehicles, including the length and position of the chambers along the tanker body.
A dynamic simulation model for a tanker ship along the Rhine River has been proposed, based on a simplified computational scheme, involving a two-degree-of-freedom roll plane multibody system, subjected to lateral accelerations estimated on the basis of measured data. The resulting equations of motion are solved through the transition matrix approach. The results suggest that many contributing factors were involved in the capsizing of the ship, including the relatively high speed of the river water and the meandering path of the infrastructure, further affected by dynamic effects derived from the behavior of the payload and from the steering maneuvers performed.
Rear-end crashes involving heavy trucks as the leading vehicle, and cars as the impact vehicle, cause many deaths and permanent injuries to car´s occupants. Measures have been thus taken in the trucks to prevent underride crashes, including the mounting of stiffer underride guards, set at car´s bumper height. In this respect, an active acceleration system(AAS), installed in the truck, could also contribute to mitigate the effects of These crashes, through the decrease of the relative Speed of the vehicles at the instant of the crash. In this paper, an AAS system is proposed, under the principles of ultrasonic sensors and an actuator for the truck´s accelerator mechanism. Simulation results of the operation of this AAS system, suggest that such a system could decrease the relative impact speed around 8% for an initial relative speed of 10 m/s.
The application of lightweight materials for tanks for transportation appears promising. Besides saving weight and therefore transportation costs, new complex geometries that depart from common cylindrical shapes of steel tanks can be manufactured. For transportation of dangerous goods, fire and explosion safety must be maintained to prevent accidents with serious consequences. In this work the fire behavior of lightweight tanks made from glass fiber reinforced plastics (GFRP) with complex geometries is investigated. Pretests on intermediate scale GFRP plates are conducted to identify suitable fire protection systems and surface treatments for composite tanks. The fire resistance is shown to be improved by addition of fire protective coatings and integrated layers. Finally, a complex rectangular GFRP tank with a holding capacity of 1100 liters is fire protected with an intumescent fire coating. The tank is filled up to 80 % with water and burned under an engulfing fully developed fire. It was shown that the intumescent layer could expand before the decomposition of the resin occurred. Furthermore, the adhesion between tank surface and coating was maintained. The structure could withstand a fire for more than 20 min.
It was possible to achieve an error as 9% or even 0% at certain time steps, as shown in the graph above, the usage of UDF code has major importance in achieving the pressure Profile required, and it heat transfer between the bottle itself and the surroundings was taken into consideration which of course had a high influence on how the temperature of the air flask changes.