Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (9)
- Vortrag (2)
- Zeitschriftenartikel (1)
- Posterpräsentation (1)
Schlagworte
- Ferroelectret (5)
- Air-coupled ultrasonic testing (4)
- Air-coupled (3)
- Luftultraschall (3)
- Carbon-fiber-reinforced plastic (2)
- Cellular polypropylene (2)
- Ferroelectrets (2)
- Ferroelektret (2)
- Focused sound fields (2)
- Thermoacoustic (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (2)
Sensitivitätsanalyse des Eigenspannungszustandes in Composite-Druckgefäßen mittels Modalanalyse
(2017)
Auf Grund ihrer hohen spezifischen Festigkeit sowie des damit einhergehenden Gewichtsvorteils kommt es bei der Auslegung von Druckgefäßen vermehrt zum Einsatz von faserverstärkten Kunststoffverbunden. Im Rahmen eines Forschungsprojektes an der Bundesanstalt für Materialforschung und –prüfung (BAM) wird das Alterungsverhalten von Atemluftflaschen in Verbundbauweise untersucht, um künftig genauere Aussagen zur Abschätzung der Lebensdauer geben zu können. Gegenstand der hier aufgezeigten Untersuchungen bilden dabei Typ-III Druckgefäße mit metallischen Liner und einer kohlefaserverstärkten Armierung. Als wichtiger, der Betriebsfestigkeit zugrunde legender Parameter wurden Druckeigenspannungen im Aluminium-Liner ausgemacht, welche fertigungsseitig zur Steigerung der Lastwechselfestigkeit in die Druckgefäße induziert werden.
Ziel ist es, mit Hilfe einer Modalanalyse die aufgezeigten inneren Spannungsverhältnisse durch eine genaue Betrachtung der modalen Parameter zu identifizieren und zu bewerten. Durch den Aufbau eines Finite-Elemente Modells und einer anschließenden Sensitivitätsanalyse der Fertigungsparameter werden zunächst Potential und Aussagekraft des Analyseverfahrens geprüft und bewertet. Anschließend erfolgt eine Eingrenzung relevanter Schwingformen sowie eine Abschätzung zu erwartender spannungsabhängiger Änderungen entsprechender modaler Kennwerte. Durch die Entwicklung und den Aufbau eines geeigneten Prüfstandes werden, darauf aufbauend, im Rahmen einer Betriebsschwingungsanalyse erste Messungen an Atemluftflaschen unterschiedlicher Alterungs- und Schädigungsstufen durchgeführt. Durch einen Vergleich mit Simulationsergebnissen und Erkenntnissen aus alternativ durchgeführten Eigenspannungsmessungen erfolgt abschließend eine kritische Bewertung der experimentell gewonnenen Ergebnisse.
Common air-coupled transducers for non-destructive testing consist of a piezocomposite material and several matching layers. Better acoustical matching to air is achieved by transducers based on charged cellular polypropylene (PP). This material has about hundred times lower acoustic impedance than any piezocomposite, having about the same piezoelectric coefficient. The piezoelectric properties of cellular PP are caused by the polarization of air cells. Alternatively, a ferroelectret receiver can be understood as a capacitive microphone with internal polarization creating permanent internal voltage. The sensitivity of the receiver can be increased by applying additional bias voltage. We present an ultrasonic receiver based on cellular PP including a high-voltage module providing bias voltage up to 2 kV. The application of bias voltage increased the signal by 12 to 15 dB with only 1 dB increase of the noise.
This receiver was combined with a cellular PP transmitter in through transmission to inspect several test specimens consisting of glass-fiber-reinforced polymer face sheets and a porous closed-cell PVC core. These test specimens were inspected before and after load. Fatigue cracks in the porous PVC core and some fatigue damage in the face sheets were detected. These test specimens were originally developed to emulate a rotor blade segment of a wind power plant. Similar composite materials are used in lightweight aircrafts for the general aviation. The other inspected test specimen was a composite consisted of glass-fiber-reinforced polymer face sheets and a wooden core. The structure of the wooden core could be detected only with cellular PP transducers, while commercial air-coupled transducers lacked the necessary sensitivity. Measured on a 4-mm thick carbon-fiber-reinforced polymer plate, cellular PP transducers with additional bias voltage achieved a 32 dB higher signal-to-noise ratio than commercial air-coupled transducers.
Im EMRP-Projekt VITCEA werden komplementäre ZFP-Verfahren zur Prüfung von Faserverbundwerkstoffen weiterentwickelt und validiert. In diesem Beitrag werden Ergebnisse verschiedener Techniken der aktiven Thermografie und des Ultraschalls vorgestellt. Die Nachweisempfindlichkeiten bezüglich künstlicher und natürlicher Fehler mit unterschiedlichen lateralen Ausdehnungen und in verschiedenen Tiefen werden miteinander verglichen.