Filtern
Dokumenttyp
- Zeitschriftenartikel (12)
- Vortrag (9)
- Posterpräsentation (3)
- Beitrag zu einem Tagungsband (1)
- Forschungsdatensatz (1)
Schlagworte
- Computed tomography (9)
- X-ray computed tomography (9)
- Additive manufacturing (6)
- Data processing (4)
- Porosity (4)
- 3D printing (2)
- ANFO (2)
- Ammonium nitrate (2)
- Chaboche model (2)
- Computertomographie (2)
- Explosives (2)
- GTN model (2)
- Implants (2)
- Metrology (2)
- Non-destructive characterisation (2)
- Prill (2)
- Specific surface area (2)
- Surface area (2)
- X-ray refraction (2)
- XCT (2)
- 3D printing Polyamide 12 (1)
- Additive Fertigung (AM) (1)
- Anisotropy (1)
- Autocorrelation function (1)
- Beam hardening (1)
- CT (1)
- Calcium phosphate (1)
- Ceramics (1)
- Coating (1)
- Composite panel (1)
- Correlation map (1)
- Damage (1)
- Damage analysis (1)
- Damage correlation map (1)
- Damage histogram (1)
- Defect detection (1)
- Delamination (1)
- Diesel particulates filter (1)
- Digital Volume Correlation (1)
- Electron beam melting (1)
- FEM (1)
- High Strength Concrete (1)
- Impact damage (1)
- Implant (1)
- In-situ Computed Tomography (1)
- Industry 4.0 (1)
- Laser beam melting (1)
- Lattice structure (1)
- Lattice structures (1)
- Maskinteknik (1)
- Material and damage behaviour (1)
- Mechanical Engineering (1)
- Mechanical properties (1)
- Medical implants (1)
- Microstructural analysis (1)
- Multiple-layered scaffold (1)
- Neutron diffraction (1)
- Normung (1)
- Numerische Simulation (1)
- Panels (1)
- Parabolic flight (1)
- Part geometry (1)
- Part material (1)
- Partial volume effect (1)
- Permeability tensor (1)
- Polyamid 12 (1)
- Polyamide 12 (1)
- Polycaprolactone (1)
- Refraction (1)
- Röntgen-Refraktion (1)
- Röntgenrefraktion (1)
- SLS (1)
- Schadensanalyse (1)
- Time-lapse X-ray computed tomography (1)
- Viscoplastic (1)
- X-Ray refraction (1)
- aRTist (1)
- composites (1)
- standardization (1)
- µ-gravity (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (26) (entfernen)
Eingeladener Vortrag
- nein (9)
The quantification of experimental and data analysis errors is most of the times jeopardised by the presence of surface roughness, waviness, as well as by typical measurement artefacts of the XCT technique (for instance refraction at sharp edges). One way to at least estimate the influence of those factors on dimensional measurements and on tolerances is to simulate them using Monte-Carlo method. An alternative strategy is to use independent knowledge (e.g. CMM data) to smoothen/calibrate/correct XCT data.
In this paper we report on the characterization by X-ray computed tomography of calcium phosphate (CaP) and polycaprolactone (PCL) coatings on Ti-6Al-4V alloy scaffolds used as a material for medical implants. The cylindrical scaffold has greater porosity of the inner part than the external part, thus, mimicking trabecular and cortical bone, respectively. The prismatic scaffolds have uniform porosity. Surface of the scaffolds was modified with calcium phosphate (CaP) and polycaprolactone (PCL) by dip-coating to improve biocompatibility and mechanical properties. Computed tomography performed with X-ray and synchrotron radiation revealed the defects of structure and morphology of CaP and PCL coatings showing small platelet-like and spider-web-like structures, respectively.
In this paper we report on the characterization by X-ray computed tomography of calcium phosphate (CaP) and polycaprolactone (PCL) coatings on Ti-6Al-4V alloy scaffolds used as a material for medical implants. The cylindrical scaffold has greater porosity of the inner part than the external part, thus, mimicking trabecular and cortical bone, respectively. The prismatic scaffolds have uniform porosity. Surface of the scaffolds was modified with calcium phosphate (CaP) and polycaprolactone (PCL) by dip-coating to improve biocompatibility and mechanical properties. Computed tomography performed with X-ray and synchrotron radiation revealed the defects of structure and morphology of CaP and PCL coatings showing small platelet-like and spider-web-like structures, respectively.
Time-dependent in situ measurement of atmospheric corrosion rates of duplex stainless steel wires
(2018)
Corrosion rates of strained grade UNS S32202 (2202) and UNS S32205 (2205) duplex stainless steel wires have been measured, in situ, using time-lapse X-ray computed tomography. Exposures to chloride-containing (MgCl2) atmospheric environments at 50 °C (12–15 M Cl− and pH ~5) with different mechanical elastic and elastic/plastic loads were carried out over a period of 21 months. The corrosion rates for grade 2202 increased over time, showing selective dissolution with shallow corrosion sites, coalescing along the surface of the wire. Corrosion rates of grade 2205 decreased over time, showing both selective and pitting corrosion with more localised attack, growing preferentially in depth. The nucleation of stress corrosion cracking was observed in both wires.
An ultrasonic vibration post-treatment procedure was suggested for additively manufac-tured lattices. The aim of the present research was to investigate mechanical properties andthe differences in mechanical behavior and fracture modes of Ti6Al4V scaffolds treated withtraditional powder recovery system (PRS) and ultrasound vibration (USV). Scanning electronmicroscopy (SEM) was used to investigate the strut surface and the fracture surface mor-phology. X-ray computed tomography (CT) was employed to evaluate the inner structure,strut dimensions, pore size, as well as the surface morphology of additively manufacturedporous scaffolds. Uniaxial compression tests were conducted to obtain elastic modulus,compressive ultimate strength and yield stress. Finite element analysis was performedfor a body-centered cubic (BCC) element-based model and for CT-based reconstructiondata, as well as for a two-zone scaffold model to evaluate stress distribution during elasticdeformation. The scaffold with PRS post treatment displayed ductile behavior, while USVtreated scaffold displayed fragile behavior. Double barrel formation of PRS treated scaffoldwas observed during deformation. Finite element analysis for the CT-based reconstructionrevealed the strong impact of surface morphology on the stress distribution in comparisonwith BCC cell model because of partially molten metal particles on the surface of struts,which usually remain unstressed.
The mixture of ammonium nitrate (AN) prills and fuel oil (FO), usually referred to as ANFO, is extensively used in the mining industry as a bulk explosive. One of the major performance predictors of ANFO mixtures is the fuel oil retention, which is itself governed by the complex pore structure of the AN prills. In this study, we present how X-ray computed tomography (XCT), and the associated advanced data processing workflow, can be used to fully characterise the structure and morphology of AN prills. We show that structural parameters such as volume fraction of the different phases and morphological parameters such as specific surface area and shape factor can be reliably extracted from the XCT data, and that there is a good agreement with the measured oil retention values. Importantly, oil retention measurements (qualifying the efficiency of ANFO as explosives) correlate well with the specific surface area determined by XCT. XCT can therefore be employed non-destructively; it can accurately evaluate and characterise porosity in ammonium nitrate prills, and even predict their efficiency.
We show how the combination of the spatial autocorrelation function and permeability calculations, applied to 3D X-ray computed tomography data, can yield quantitative information on the anisotropy of both meso-structure and fluid flow in Diesel Particulate Filter (DPF) materials, such as Cordierite and SiC. It was found that both the degree of anisotropy, and the orientation of the permeability and meso-structure are similar, but not identical. We confirm that the morphological anisotropy of cordierite materials is weak, and clearly influenced by the extrusion process that determines the main direction of anisotropy. Properties of the autocorrelation function are discussed and it is shown why estimating the characteristic length of real meso-structures (grain or ?pore? size) is not possible. Finally, we show that the autocorrelation function applied on grey-level images can give a good estimate of the degree of anisotropy even with limited resolution.
Nominal-actual comparisons are routinely performed to compare a manufactured specimen to a reference specimen. X-ray Computed Tomography (CT) has brought a profound change in the way that tolerance verifications are performed in industry, by allowing the inner and outer geometries of an object to be measured, without the need for external access or destructive testing. As a results, CT is increasingly used in additive manufacturing applications, where a nominal-actual comparison performed between the digital model (CAD file), used as an input for the 3D printer, and the CT volume from the printed part, can provide invaluable information as to the accuracy of the printing process. However, the nominal-actual comparison process is somewhat different when applied to additively manufactured specimens by comparison to conventionally manufactured specimens.