Within the framework of the European project PICASSO, the radiographic simulator aRTist (analytical Radiographic Testing inspection simulation tool) developed by BAM has been extended for reliability assessment of film and digital radiography. NDT of safety relevant components of aerospace industry requires the proof of probability of detection (POD) of the inspection. Modeling tools can reduce the expense of such extended, time consuming NDT trials, if the result of simulation fits to the experiment. Our analytic simulation tool consists of three modules for the description of the radiation source, the interaction of radiation with test pieces and flaws, and the detection process with special focus on film and digital industrial radiography. It features high processing speed with near–interactive frame rates and a high level of realism. A concept has been developed as well as a software extension for reliability investigations, completed by a user interface for planning automatic simulations with varying parameters and defects. Furthermore, an automatic image analysis procedure is included to evaluate the defect visibility. The radiographic modeling from 3D CAD of aero engine components and quality test samples are compared as a precondition for real trials. This enables the evaluation and optimization of film replacement for application of modern digital equipment for economical NDT and defined POD.
Concepts for digital image evaluation are presented for Computed Radiography (CR) and Digital Detector Arrays (DDAs) used for weld inspection. The precise DDA calibration yields an extra ordinary increase of contrast sensitivity up to 10 times in relation to film radiography. Restrictions in spatial resolution caused by pixel size of the DDA are compensated by increased contrast sensitivity. First CR standards were published in 2005 to support the application of phosphor imaging plates in lieu of X-ray film, but they need already a revision based on experiences reported by many users. One of the key concepts is the usage of signal-to-noise (SNR) measurements as equivalent to the optical density of film and film system class. The contrast sensitivity, measured by IQI visibility, depends on three essential parameters: The basic spatial resolution (SRb) of the radiographic image, the achieved signal-to-noise ratio (SNR) and the specific contrast (µeff - effective attenuation coefficient). Knowing these 3 parameters for the given exposure condition, inspected material and monitor viewing condition permits the calculation of the just visible IQI element. Furthermore, this enables the optimization of exposure conditions. The new ISO/FDIS 17636-2 describes the practice for digital radiography with CR and DDAs. It considers the first time compensation principles, derived from the three essential parameters. The consequences are described.
Best energy selection for different applications with digital detector arrays from 20 to 600 keV
(2012)
Es wird über die neuen Anforderungen ausgewählter Normen bzw. Normrevisionen informiert und insbesondere auch über die veränderten Parameter, die bei der Prüfpraxis, der Qualitätssicherung in der digitalen Radiographie und bei der Klassifizierung zu berücksichtigen sind. Das wichtigste Projekt ist die Revision der DIN EN ISO 17636-1, -2, RT von Schweißverbindungen, in ISO TC 44 SC 5 WG 1. Hauptaktivität bei ASTM ist gegenwärtig die Überarbeitung der CT-Standards und die Berücksichtigung der Anforderungen an das dimensionelle Messen. Der „Standard Guide for Computed Tomography“, ASTM E 1441, zur Bestimmung von MTF, Kontrast-Detail-Funktion (CDF) und Kontrast-Diskrimination-Diagramm (CDD) wurde revidiert und veröffentlicht. Die Mehrzahl der Hersteller von CT-Anlagen bietet entsprechende Software-Tools an. Weiterhin werden neue Festkörperentwürfe zur Charakterisierung von CT-Anlagen vorgestellt. Die folgenden Revisionen sind bei ASTM derzeit in Bearbeitung: ASTM E 2445, „CR Long Term Stability“ nach einem Round Robin-Test und für DDAs der Standard zur System-Charakterisierung, ASTM E2597/E2597M−14, und zur „DDA Long Term Stability“. Das Spider-Net-Diagramm zur Klassifizierung von DDAs wird um die Position „ISO Material Thickness limit“ erweitert. Der Standard EN 12679 zur Messung der Größe von Gammastrahlern wurde nach Revision unter Berücksichtigung von digitalen Messverfahren veröffentlicht. Die Revision der Standardserie EN 12543 zur Messung der Brennfleckgröße ist mit Verzögerung in Überarbeitung, um die digitalen Detektoren und Messmöglichkeiten mit Bildverarbeitungsprogrammen zu berücksichtigen. Die Messprozedur für Lochkameras wurde grundlegend revidiert und ist harmonisiert mit ASTM E 1165-12(2017). Die gemessenen Brennflecke unterscheiden sich und passen besser zu den Unschärfe-Messungen
mit Doppeldraht BPKs (ISO 19232-5:2018) bei Vergrößerung. Ein Entwurf zur Messung der Brennfleckgröße von nano-Fokusröhren und Mikro-Fokusröhren (< 5 µm) wird derzeit vom Europäischen Metrologie-Programm EMPIR gefördert. Es wird über erste Ergebnisse
informiert.