Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (133)
- Beitrag zu einem Tagungsband (98)
- Zeitschriftenartikel (77)
- Beitrag zu einem Sammelband (47)
- Posterpräsentation (38)
- Buchkapitel (4)
- Corrigendum (2)
- Sonstiges (2)
- Forschungsbericht (2)
- Dissertation (1)
Schlagworte
- Concrete (78)
- Ultrasound (76)
- Monitoring (58)
- Coda wave interferometry (25)
- Non-destructive testing (22)
- Ultraschall (22)
- NDT (19)
- Imaging (17)
- Beton (14)
- Radar (14)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (145)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (143)
- 7 Bauwerkssicherheit (5)
- 8.6 Faseroptische Sensorik (5)
- 7.2 Ingenieurbau (2)
- 7.4 Baustofftechnologie (2)
- 8.0 Abteilungsleitung und andere (2)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 8.5 Röntgenbildgebung (2)
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (133)
BAW and BAM have performed a large scale comparison and calibration test on static and dynamic load capacity evaluation of bored piles in glacial sandy soil. The test was performed using eight piles at the BAM test site for technical safety at Horstwalde 50 km south of Berlin. The test area has been prepared and investigated in great detail using boreholes, cone penetration tests, pore pressure sensors and geophysical methods to assure controlled conditions for all piles and tests. The piles (10 m length, 0.9 m diameter) are mainly friction piles (low toe resistance) and have been checked by integrity testing. Five piles have been tested by five contractors using the dynamic method in a blind experiment, the other ones piles by static load and/or later on by the dynamic method. Some piles have been equipped with additional fibre optic Instrumentation which proved to be robust and helpful in interpreting the results of static, dynamic and integrity tests. We have experienced a deviation of the dynamic load test results gathered in the blind experiment from the static values of up to 20% in most cases, sometimes even up to 30%. This can be related to the known soil inhomogeneities, interpretation and modelling in CAPWAP and method inherent uncertainties. In cases where the static values were known by the testers for calibration, the deviations were significantly smaller. It has to be taken into account, that the two static load tests showed different results as well. Due to the low toe resistance, use of a big drop weight (11 tons) and large drop heights most piles suffered from cracking, which was clearly seen in follow up integrity tests and confirmed by excavation. The piles are available for further research.
The aim of this work is to improve the current structural health monitoring (SHM) methods for civil structures. A field experiment was carried out on a two-span bridge with a built-in un-bonded prestressing system. The bridge is a 24-metre long concrete beam resting on three bear-ings. Cracks were formed subsequently when a prestressing force of 350 kN was changed to 200 kN, so that different structural states could be demonstrated. The structural assessment of this reference bridge was accomplished by the non-destructive testing using ultrasonic devices and vibration measurements. The ultrasonic velocity variations were investigated by using the coda wave interferometry method. The seismic interferometry technique was applied to the vi-bration recordings to reconstruct the wave propagation field in the bridge. This investigation shows that the wave velocity is sensitive to the current structural state and can be considered as the damage indicator. Overall, the implementation of coda cave interferometry and seismic interferometry technique facilitates structural health monitoring (SHM) in civil engineering.
Die B1 Brücke am Altstädter Bahnhof in Brandenburg an der Havel wurde im Dezember 2019 aufgrund von während einer turnusmäßigen Inspektion entdeckten Rissen und Hohlstellen entlang der vorgespannten Längsträger gesperrt und im Mai 2021 abgebrochen. In der Zwischenzeit wurde die Brücke detailliert überwacht. Vor dem Abriss wurden zudem umfangreiche Untersuchungen zur Bestandsaufnahme und Schadensanalyse sowie Tests moderner Sensorik vorgenommen. Dabei konnte sowohl die richtige, zuvor nicht sicher bekannte Anzahl von Spanngliedern in den Querträgern sicher ermittelt werden als auch durch moderne Varianten der Schwingungsmessungen und der faseroptischen Sensorik zusätzliche Kenntnisse püber das Bauwerksverhalten ermittelt werden . In dem Beitrag werden die Verfahren mit ihren Möglichkeiten und Grenzen vorgestellt, die Ergebnissee an der Brücke in Brandenburg erläutert und zukünftige Einsatzmöglichkeiten diskutiert.