(2006)
Seismic wave velocities are related to elastic moduli and other properties and can serve as indicators for changes in the material. They are conventionally determined by active measurements. Using ideas from seismic interferometry determination from stacked cross-correlations of registrations of man-made and natural noise (“passive seimics“) is an effective alternative, as these data might be available from vibration monitoring anyway. The validity of this approach is demonstrated by a simple experiment based on recordings of man made noise using accelerometers at the reference structure. The s-wave (or more probable. guided wave) velocity was determined to be 2100 m/s in both active and passive experiments.
Bridge monitoring using embedded ultrasonics First results from the BLEIB reference structure
(2017)
The BLEIB reference structure The structure is a two-span, 24 m long inverse u-shaped post-tensioned concrete beam. Fibre optic sensing cables, RFID sensors and ultrasonic transducers are permanently embedded. Other sensing techniques (vibrational, optical, ultrasonic, mechanical) are applied externally. Tension can be adjusted. Loads can be placed at arbitrary locations. Limited damage is introduced to one span. The BLEIB reference structure is located at BAM‘s test site in Horstwalde, south of Berlin. Ultrasonic transducer before concreting.
Embedded ultrasonic transducers 14 piezo transducers have been embedded before concreting. They are located in five sections, two close to the centers of both spans respectively and one above the central bearing.
Load experiment and data evaluation In a first experiment load 2 (weight 2 t) was moved three times along the southern (right) span. The tension forces were modified as well.
Ultrasonic transmission measurements were repeated over time and evaluated using Coda Wave Interferomerry (CWI), which determines correlation coefficients and relative velocity changes as subtle indicators for loads and other changes in the material.
Multifaceted developments for pre-disposal management of low and intermediate level radioactive waste are undertaken in the EC funded project PREDIS. In work package 7, innovations in cemented waste handling and pre-disposal storage are advanced by testing and evaluating. To provide better means for safe and effective monitoring of cemented waste packages including prediction tools to assess the future integrity development during pre-disposal activities, several monitoring and digital tools are evaluated and improved. Both safety enhancement (e. g. less exposure of testing personnel) and cost effectiveness are part of the intended impact. Current methods to pack, store, and monitor cemented wastes are identified, analysed and improved. Innovative integrity testing and monitoring techniques applied to evaluate and demonstrate package and storage quality assurance are further developed. The work includes but is not limited to inspection methods such as muon imaging, wireless sensors integrated into waste packages as well as external package and facility monitoring such as remote fiber optical sensors. The sensors applied will go beyond radiation monitoring and include proxy parameters important for long term integrity assessment (e. g. internal pressure). The measured data will be used in digital twins of the packages for specific simulations (geochemical, integrity) providing a prediction of future behaviour. Machine Learning techniques trained by the characterization of older packages will help to connect the models to the actual data. As data handling, processing and fusion are crucial for both the monitoring and the digital twin model, all data (measured and simulated) will be collected in a joint data base and connected to a decision framework. Finally, the implementation of the improved techniques will be tested at actual facilities. An overview about various relevant tools, their interconnections, and first research results will be shown.