Filtern
Erscheinungsjahr
- 2021 (3) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (1)
- Beitrag zu einem Tagungsband (1)
- Vortrag (1)
Sprache
- Englisch (3)
Referierte Publikation
- nein (3)
Schlagworte
- Non-destructive testing (3) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
News from NDT@BAM
(2021)
The presentation summarizes some recent research at BAM in the field of NDT in civil engineering. the firste xample decribes lab experiments on the degardation of concrete during tunnel fires. Radar measuremenst were sucessfully used to detect interior damage. The second example decribes the first ever experiment on using muon imaging to evaluate concrete constructions.
The aim of this work is to improve the current structural health monitoring (SHM) methods for civil structures. A field experiment was carried out on a two-span bridge with a built-in un-bonded prestressing system. The bridge is a 24-metre long concrete beam resting on three bear-ings. Cracks were formed subsequently when a prestressing force of 350 kN was changed to 200 kN, so that different structural states could be demonstrated. The structural assessment of this reference bridge was accomplished by the non-destructive testing using ultrasonic devices and vibration measurements. The ultrasonic velocity variations were investigated by using the coda wave interferometry method. The seismic interferometry technique was applied to the vi-bration recordings to reconstruct the wave propagation field in the bridge. This investigation shows that the wave velocity is sensitive to the current structural state and can be considered as the damage indicator. Overall, the implementation of coda cave interferometry and seismic interferometry technique facilitates structural health monitoring (SHM) in civil engineering.
This paper describes a new ultrasonic measuring device called “W-Box”. It was developed based on the requirements of the DFG Forschergruppe (research unit) CoDA for a portable device for monitoring of concrete specimens, models and actual structures using embedded ultrasonic transducers as well as temperature and humidity sensors. The W-Box can send ultrasonic pulses with a variable frequency of 50–100 kHz to one selectable transducer and records signals from up to 75 multiplexed channels with a sample rate of 1 MHz and a resolution of 14 bits. In addition, it measures temperature and humidity with high accuracy, adjustable amplification, restarts automatically after a power failure and can be fully controlled remotely. The measured data are automatically stored locally on-site data quality checks and transferred to remote servers. The comparison of the W-Box with a laboratory setup using commercial devices proves that it is equally reliable and precise, at much lower cost. The W-Box also shows that their measurement capacities, with the used embedded ultrasonic transducers, can reach above 6 m in concrete.