Organisationseinheit der BAM
According to the NBI database, more than 21,000 in-service U.S. bridges lack sufficient structural documentation necessary for analytical load rating. Among these are a significant proportion of older prestressed concrete bridges. Given the lack of documentation on the reinforcing layout, such structures cannot be load rated analytically and are often subject to engineering judgement as the basis for rating. Otherwise, the typical approach for load rating such bridges is to conduct costly proof load testing and destructive probing together with making conservative assumptions. Therefore, any improvement to current practices will benefit DOTs and taxpayers alike. Accurately reconstructed 3D images of the girders to reflect the internal reinforcement could mitigate the need for costly, if not impractical, destructive testing and proof load testing, and help reduce dependency on conservative assumptions. This study examines a comprehensive NDE approach using ultrasonic tomography and GPR to aid in gathering structural information for load rating purposes. Different types of AASHTO and hollow core girders were tested.
Previous work has shown that ultrasonic monitoring using externally applied or embedded transducers and imaging methods based on coda wave interferometry are able to detect subtle changes in concrete elements. In this study, a limited number of embedded transducers has been used to monitor changes in several 12 m long two-span concrete beams subjected to point or linear loads until failure.
The ultrasonic results showed the high sensitivity to stress changes and the nonlinear character of the associated effects. However, the ultrasonic features showed a very good correlation to several conventional monitoring parameters. For higher loads (significant amount of cracking), the technique had to be modified to cope with large wave velocity variations and high decorrelation compared to the reference signal.
Using a very simple imaging procedure, the 2D stress field inside the beam has been visualized including inhomogeneities and artifact at places where cracking occurred at higher loads. The technique has the potential to be included in real time monitoring systems.
Bridge monitoring using embedded ultrasonics First results from the BLEIB reference structure
(2017)
The BLEIB reference structure The structure is a two-span, 24 m long inverse u-shaped post-tensioned concrete beam. Fibre optic sensing cables, RFID sensors and ultrasonic transducers are permanently embedded. Other sensing techniques (vibrational, optical, ultrasonic, mechanical) are applied externally. Tension can be adjusted. Loads can be placed at arbitrary locations. Limited damage is introduced to one span. The BLEIB reference structure is located at BAM‘s test site in Horstwalde, south of Berlin. Ultrasonic transducer before concreting.
Embedded ultrasonic transducers 14 piezo transducers have been embedded before concreting. They are located in five sections, two close to the centers of both spans respectively and one above the central bearing.
Load experiment and data evaluation In a first experiment load 2 (weight 2 t) was moved three times along the southern (right) span. The tension forces were modified as well.
Ultrasonic transmission measurements were repeated over time and evaluated using Coda Wave Interferomerry (CWI), which determines correlation coefficients and relative velocity changes as subtle indicators for loads and other changes in the material.