NDT investigation methods
(2006)
Civil engineering industry is one of the most important industry sectors in the world-wide economy. It contributes significantly to the gross economic product and general employment. Even more important, it provides many of the basic needs of the society (e. g. housing, infrastructure, protection from natural hazards).
The concept of “Industry 4.0” or “Smart Production” has not yet made significant progress in the civil engineering industry. The design, build and operate processes are still widely dominated by the exchange of printed documents and drawings. Most objects (buildings and other constructions) are unique, and a large part of the production still requires a large amount of manual labor. As-built documentation and quality assurance are often neglected. Civil engineering is among the industries sectors with the lowest level of digitalization and the lowest gain in productivity.
However, this is going to change. In the past decade, several drivers have challenged the ways clients, contractors, and authorities currently operate. These drivers include but are not limited to an increasing demand for serialization and automatization, the mandatory introduction of “Building Information Modeling” (BIM) in public procurement, the availability of construction equipment with sensors and digital interfaces or emerging automated construction technologies such as 3D-printing.
NDE (referred to as NDT-CE in this sector), after a rapid technological development in the last two decades, plays an increasing role in quality assurance, condition assessment and monitoring of structures. However, with very few exceptions, applications are mostly non-standardized and performed only at selected sites. To change this, the NDT-CE community including manufacturers, service providers, clients and the scientific community must work consistently on open data formats, interfaces to BIM, standardization and validated ways for a quantitative use of the results in the assessment of constructions.
NDE of foundations
(2019)
This talk teaches the basic princioles and applications of NDT methods for deep foundations, sprecifically piles. A variety of testing methods are discussed (integrity testing, ultrasonic crosshole logging, parallel seismic and others). Capabilities and limitations are given as well as specific hints for practical use.
Concrete piles are used as a foundation when the load capacity of the soil is insufficient or when the sustainable soil is found at a higher depth. Among other impact factors, the load capacity depends on the pile’s integrity and length.
Therefore, verifying these parameters using adequate methods is recommended. The most common procedure is the low-strain integrity test using the hammer impact method. Developed and established in the 1970s, this method uses stress waves induced by a hammer impact at the pile head and its reflections at impedance changes (length, defects, geometry changes) to estimate the length and defect locations. Although this method is widely used due to its low cost and fast conduction in situ, one disadvantage is its inability to classify the exact type of defect, i.e., crack, change in diameter, or concrete quality. Furthermore, very long and slender piles are difficult to test and small defects cannot be detected. In addition, it is necessary for the test engineer to hold a high level of experience and expertise in this field. The European Union–funded PileInspect project (2013–2016) aimed to compensate for these disadvantages by using a low-cost shaker as the excitation source and sophisticated artificial intelligence algorithms for damage detection (higher-order spectra method). Because this technology lacks the capacity to localize damages and verify the pile length, an additional impulse response (IR) measurement technique was developed using vibrational excitation and regularized deconvolution to extract the depth information from the data in a similar manner as the hammer method.
Simulations and subsequent experiments conducted at a test facility on 90-cm-diameter bored piles 11 m in length and containing cracks at approximately 4 m below the pile head confirmed the capacity to determine the pile length.
Damage diagnosis and localization, however, are more difficult than for the hammer method. Although the damaged piles could be distinguished from the intact piles, in a blind test, this method might lead to misinterpretations caused by perturbations arising from the deconvolution process. The results also indicated that the low-cost shaker used for these measurements might be inappropriate for
the transferal of sufficient energy. Although the IR method cannot compensate for the disadvantages of the hammer method by itself, it may enable the possibility of using long and fully controllable and repeatable signals (chirp, synthetic impacts, even noise, etc.) for pile integrity testing in the future.