Filtern
Erscheinungsjahr
- 2015 (2) (entfernen)
Dokumenttyp
- Beitrag zu einem Tagungsband (2) (entfernen)
Sprache
- Englisch (2) (entfernen)
Referierte Publikation
- nein (2)
Schlagworte
- Damage detection (1)
- Deconvolution (1)
- Impulse response function (1)
- Low strain pile integrity testing (1)
- Pile inspect (1)
- Pile integrity (1)
- Piles (1)
- Shaker (1)
- Sine sweep excitation (1)
- Ultraseismic (1)
Defect detection in concrete pile using impulse response measurements with sine sweep excitations
(2015)
For pile integrity inspection, a low cost and portable shaker was used to create the sine sweep signal for pile excitation. The impulse response function, calculated by the deconvolution of pile response from the sine sweep excitation, was proposed to identify the echoes in the piles due to the pile’s impedance changes. The proposed methodology has been evaluated and validated both numerically and experimentally. Based on the results from the simulations and experiments, it was found that the impulse response measurement with sine sweep excitation could be an effective tool to detect the echoes of the pile toe and the defects in the pile.
Low strain pile integrity testing is an established method in QA of foundation piles. The technique is very effective and well accepted for larger flaws and length determination. It is part of standards and recommendations. Challenges exist for more complicated structures (e. g. pile walls, diaphragm walls, and pile under structures) and small flaws. Interpretation is subjective in many cases. Possible solutions, e.g. the use of vibrators instead of a hammer or application of several sensors instead of one have been proposed decades ago, but not used much in practice. In several projects we are working on the extension and optimizations of these ideas, based on input from other engineering disciplines. In the frame of the project PileInspect we are working with an international consortium on the use of vibrators instead of a hand held hammer. This allows the full control of input signals as well as the use of (semi)automatic classification routines from machine diagnosis. At BAM we are using a low cost vibrator and deconvolution routines to improve the results of classical low strain testing. In another project we are working on multichannel measurements with sensor placement along the pile axis. This can be used to determine the travel direction of certain waves (downwards or upwards) to improve the interpretation of measurements on piles below constructions or pile walls. The use of ideas adapted from geophysics („vertical seismic profiling“) are helpful. Both concepts are proven by simulations results and first field tests.