Filtern
Erscheinungsjahr
- 2019 (25) (entfernen)
Dokumenttyp
Schlagworte
- Concrete (11)
- Monitoring (8)
- Ultrasound (8)
- NDT (5)
- Coda wave interferometry (3)
- Pile integrity testing (3)
- Air-coupled ultrasound (2)
- Deconvolution (2)
- Defect detection (2)
- Engineered Barrier System (EBS) (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (9)
The reuse of existing foundations is considered in various construction Projects to save time and costs while avoiding unnecessary interference with other underground objects. Because the design and as-built drawings might not be complete and questions may arise regarding the condition of the foundations, a detailed investigation is a prerequisite for the planning process in most cases. Nondestructive testing (NDT) techniques are a core part of this endeavor.
The processes and procedure for foundation reuse planning are not yet standardized, and the possibilities and limitations of NDT methods are not known to many planners and stakeholders. The German research Project REFUND (2014–2016) has developed charts for the planning and Investigation process that consider available standards and the current state of the art in NDT.
These charts are separately available for single and strip, slab, and pile foundations. Available NDT methods have been compiled and evaluated for specific tasks at these foundation types, including their respective limitations.
The procedures have been successfully tested in two real-world projects. The results from these projects enable planners to improve the reliability of the process while potentially saving significant resources. This paper discusses the procedures for pile foundations and demonstrates the use of various NDT methods in a project on the reuse of electrical tower foundations.
In this study, an Impulse Response Function analysis of pile response to sine-sweep excitation by a low cost, portable Shaker was used to identify defects in piles. In straightforward impact-echo methods, echoes from the pile toe and defects are visible in the time domain measurements. However, these echoes are not present in the time domain records of piles subjected to sine-sweep excitations, due to interactions between the input and output signals. For this reason, the impulse response function in the time domain has been calculated and is able to identify the echoes from pile impedance changes. The proposed methodology has been evaluated both numerically and experimentally. A one-dimensional pile-soil interaction system was developed, and a finite difference method used to calculate the pile response to sine-sweep excitation. The numerical simulations indicate that impulse response measurements with a synthesized logarithmic, sine-sweep excitation could be an effective tool for detecting defects in piles. The methodology was further tested with field trials on 6 cast in situ concrete test piles including 1 intact pile and 5 defective piles subjected to sine-sweep excitations by a shaker. In 5 of the 6 cases the echoes from the pile toe could be identified in the deconvoluted waveforms—the impulse Response functions. Damage detection is more difficult and dependent on the selection of the optimal regularization parameter. Further research and optimization of the deconvolution process is needed to evaluate the effectiveness compared to standard pile integrity testing methods.
The propagation of ultrasonic waves in concrete is affected by its micro- and macro-structure, geometry and properties as well as external influences as stress, temperature or moisture. In addition, age and degradation have a strong influence. Therefore, Ultrasound has been used to monitor concrete samples and structures since decades. However, early applications using conventional techniques as time-of flight or changes in amplitudes have been limited to detect changes in a late stage close to serviceability or ultimate load states.
Around 2000, several new, more sensitive techniques adopted from geophysics or other field of material sciences have been introduced to research in ultrasonic monitoring of concrete. The most discussed methodologies are coda wave interferometry, a technique which allows to detect very subtle changes from repeated ultrasonic measurements. Nonlinear acoustic techniques help to identify e. g. cracks even in an inhomogeneous background. Both techniques can be combined.
This paper reviews methods and results achieved so far on the laboratory scale and with full scale models the directions for future research and application is given as well.
PileInspect
(2019)
The EC funded project PileInspect (2013-2016) has tried to improve the traditional low strain pile integrity test by using a shaker instead of a hamm and sophisticated higher order spectra analysis methods to provide automated, reliable interpretation. However, the results, even if promising, have not seen full validation yet. A second module, providing depth information by regularized deconvolution, was developed and tested successfully, but doesn't deliver additional information compared tomteh traditioanl test.
The assessment of Coda Wave Interferometry (CWI) and Distributed Fiber Optics Sensing (DFOS) techniques for the detection of damages in a laboratory size reinforced concrete beam is presented in this paper. The sensitivity of these two novel techniques to micro cracks is discussed and compared to standard traditional sensors. Moreover, the capacity of a DFOS technique to localize cracks and quantify crack openings is also assessed. The results show that the implementation of CWI and DFOS techniques allow the detection of early subtle changes in reinforced concrete structures until crack formation. With their ability to quantify the crack opening, following early detection and localization, DFOS techniques can achieve more effective monitoring of reinforced concrete structures. Contrary to discrete sensors, CWI and DFOS techniques cover larger areas and thus provide more efficient infrastructures asset management and maintenance operations throughout the lifetime of the structure.
The LAUS: First Applications of a New System for Ultrasonic Imaging of Very Concrete Structures
(2019)
The LAUS (Large Aperture Ultrasonic System) has been developed to image very thick concrete structures, which are not accessible for commercial systems. The device and the corresponding software is the result of joint Research of BAM, an ultrasonic instrument manufacturer and University of Kassel, Germany. It consists of 12 separate Arrays of 32 point-contact shear wave transducers each, which can be deployed in flexible configurations. Each array is combined with battery and transmitter, receiver and wireless communication electronics.
Three case histories are presented. First the system was deployed on a 5-m thick heavily reinforced foundation slab.
The reflection of the slab’s bottom was imaged clearly. In addition, a multiple reflection was registered, thus giving hope that even thicker elements might be imaged by the instrument. Second, the LAUS was used to investigate a massive bridge girder where a heavy rainstorm during concreting had led to imperfections that were visible after removing the formwork was removed. The LAUS could image tendon ducts in 1.8m depth and the backwall closely behind them. Some limited areas showed blurred reflections and were checked by drill holes; these areas were affected by diffuse damage which could be repaired by injections. Third, a large retaining wall was checked for thickness.
Meanwhile, the LAUS has been used in underground waste deposits (nuclear and other) for quality assurance of sealing plugs. A confirmed penetration depth of about 7 m has been reached.
In earthquake-prone regions such as the Pacific Northwest, damage assessment tools are needed to enable safety evaluations to support recovery. Currently, damage assessment is performed primarily by visual inspection and is often impossible for structural members that are inaccessible, such as deep foundations or interior members hidden by cladding. This study explores the possibility of using embedded ultrasonic transducers to monitor reinforced concrete members for damage progression under earthquake loading. A novel methodology is proposed where changes in the member condition due to an increase in the earthquake-type loading of a full-scale column-foundation specimen are correlated with changes in the recorded ultrasonic waveforms. The discussed preliminary analysis of the ultrasonic signals is based on wave propagation velocity, changes in the coda wave portion, and maximum amplitude of the signals. Three embedded transducers were used to continuously monitor the laboratory specimen during destructive testing. This paper provides an overview of the proposed methodology, outlines the laboratory experiment, and discusses some preliminary observations.
Dieses erste Memorandum zur Lehre und Forschung an deutschsprachigen Hochschulen auf dem Gebiet der zerstörungsfreien Prüfung im Bauwesen gibt einen Überblick hinsichtlich der akademischen Ausbildung und zeigt mögliche Schwerpunkte vor allem in der Lehre auf. Diese Schwerpunkte berücksichtigen auch aktuelle Entwicklungen und Themen auf dem Gebiet der Forschung. Es werden Anregungen zur Entwicklung bzw. Weiterentwicklung der Lehr-Curricula im Hinblick auf eine umfassende und solide fachliche Ausbildung der Studierenden des Bauwesens und angrenzender Fachrichtungen gegeben. Inhaltlich und formal lehnt sich der Beitrag an dem Memorandum der Hochschullehrer im Fachgebiet „Werkstoffe im Bauwesen“ (Breit et al., 2012) an und beruht auf einer Initiative des Unterausschusses Ausbildung – Arbeitsgruppe Ausbildung in der Hochschule – des Fachausschusses ZfP im Bauwesen der Deutschen Gesellschaft für zerstörungsfreie Prüfung (DGZfP). Die Hauptredaktion wurde übernommen von Prof. Christian U. Grosse (TU München) und Prof. Ralf W. Arndt (FH Erfurt).
Ultrasonic transmission measurements are used to monitor concrete elements mostly on a laboratory scale since decades. Recently, coda wave interferometry, a technique adapted from seismology, has been introduced to civil engineering experiments. It can be used to reveal subtle changes in concrete samples and even large construction elements without having a transducer directly at the location where the change is taking place. The methodology works best with embedded transducers to avoid coupling issues or excessive environmental influence. These transducers can be used for newly built and existing structures. Recently, large concrete beams have been equipped with a network of transducers and loaded until failure. Using code wave interferometry, it was possible to visualize stress fields and damaged areas. This paper gives an overview of the state of the art, recent results achieved at BAM and a task list for further results and development.
Construction methods, environmental stressors, and aging factors are the main causes for defects of reinforced concrete in nuclear power plants (NPP). These defects are typically occurred as corrosion of reinforcement steel, delamination, cracks, malfunction of post-tensioning or steel composite systems etc. Some of the challenges for assessing the performance of these structures by nondestructive testing methods (NDT) are that the assessment could be performed only during the annual overhauls when testing is time-limited and uncertainty of the accuracy and reliability of the available NDT testing devices combined with the lack of the international uniformity of the methods used for NDT tests. To overcome these challenges, a mock-up wall representing a section of the concrete containment of the NPP was built. The mock-up wall included simulated defects, which mimic the most common types of defects in NPP concrete structures such as dimensional errors, honeycombing, delamination, defects adjacent to the steel liner and voids in grouted tendon ducts for the post-tensioned structures. This paper introduces the design and construction of the wall including the concrete properties, reinforcement, tendon ducts and the types of the simulated defects. The paper also introduces the NDT methods and techniques that are suitable for assessing the condition of the mock-up wall under the real environmental conditions. These techniques include mechanical methods as rebound hammer, ultrasonic and electromagnetic methods. This mock-up wall will enable to investigate reliably available NDT methods and experts’ skills providing also an important and very much need educational platform for future NDE experts.