The reuse of existing foundations is considered in various construction Projects to save time and costs while avoiding unnecessary interference with other underground objects. Because the design and as-built drawings might not be complete and questions may arise regarding the condition of the foundations, a detailed investigation is a prerequisite for the planning process in most cases. Nondestructive testing (NDT) techniques are a core part of this endeavor.
The processes and procedure for foundation reuse planning are not yet standardized, and the possibilities and limitations of NDT methods are not known to many planners and stakeholders. The German research Project REFUND (2014–2016) has developed charts for the planning and Investigation process that consider available standards and the current state of the art in NDT.
These charts are separately available for single and strip, slab, and pile foundations. Available NDT methods have been compiled and evaluated for specific tasks at these foundation types, including their respective limitations.
The procedures have been successfully tested in two real-world projects. The results from these projects enable planners to improve the reliability of the process while potentially saving significant resources. This paper discusses the procedures for pile foundations and demonstrates the use of various NDT methods in a project on the reuse of electrical tower foundations.
Coda wave interferometry is a recent analysis method now widely used in seismology. It uses the increased sensitivity of multiply scattered elastic waves with long travel-times for monitoring weak changes in a medium. While its application for structural monitoring has been shown to work under laboratory conditions, the usability on a real structure with known material changes had yet to be proven. This article presents experiments on a concrete bridge during construction. The results show that small velocity perturbations induced by a changing stress state in the structure can be determined even under adverse conditions. Theoretical estimations based on the stress calculations by the structural engineers are in good agreement with the measured velocity variations.
After some river embankment failures during recent floods in Germany, major investigation and improvement programs for river embankments have been implemented. Presently, the investigation mainly relies on existing documentation, visual inspection, and drilling and sampling. Geophysical techniques, which are applied non-destructively from the surface, have the potential to cover the gaps between sampling points and to enhance the reliability of subsurface information. This paper describes the evaluation results for resistivity, electromagnetic, seismic and GPR techniques acquired at a test site along the Mulde River in eastern Germany. The work was carried out under the government funded project DEISTRUKT. Each geophysical method has its own specific advantages and limitations. Keeping the requirements posed by current German guidelines for river embankments in mind, 2–D electrical resistivity tomography (ERT) is the method of first choice. However, all geophysical results have to be calibrated carefully using information, such as material properties and depth of structures, determined from boreholes. Although some recommendations are provided here, a set of detailed recommendations have been compiled in a handbook.
The low-strain pile integrity testing method is used for quality control of new piles as well as length and integrity check for old piles. If no other methods for calibration are available, the accuracy and reliability of the techniques depend on a good estimation of the elastic wave velocity. In practice it is assumed that piles can be tested 7 days after casting and that the velocity is almost constant in all piles of one kind in a construction project. Recent measurements at the BAM test site in Horstwalde, Germany, showed that the 7 day criterion is not generally applicable.
Moisture ingress is one of the major deteriorating factors for building materials. Today, the only approved way to assess such damage is the gravimetric Darr method, which is essentially destructive. Substantial progress has been made using the geophysical complex-resistivity method, which can be applied non-destructively and provides spatial information along two-dimensional sections, rather than punctual along one borehole. Considerable advantages of complex resistivity are its sensitivity to textural properties, as well as the pore-fluid chemistry of wet, porous media. In a comprehensive laboratory study, and later in field scale experiments, it could be shown that complex resistivity may even be able to distinguish between salt content and saturation degree in a single measurement. A comparison with complementary nondestructive testing techniques points to the benefit and further research to be explored in multimethodical approaches.
Ultrasonic monitoring, making use of the sensitivity of the coda of repeated transmission meas-urements to changes in stress, temperature, moisture, as well as localized or distributed damage, has gotten at-tention in structural health monitoring (SHM) research recently. Analysis methods such as coda wave inter-ferometry (CWI), including its nonlinear extension, have been shown to be able to measure ultrasonic wave velocity changes with a 1∙10-5 resolution, while indicators such as cross-correlation or cross-coherence have been used to distinguish between reversible and irreversible changes. Several small- and large-scale laboratory experiments have demonstrated that stress changes in structures can be captured or damage detected in a very early stage. The use of this technique for pre-warning before failure are currently under investigation, as well as detailed research on the physical causes and the connection between ultrasonic wave properties and materi-al/structural behavior. Recently, several of large-scale laboratory and real structures have been instrumented with embedded ultrasonic transducers to gather experience and evidence on how to use this technology in re-al-world applications. Preliminary results from installations on a new bridge, an existing bridge, a tunnel, a la-boratory earthquake test as well as a historic stadium in Germany, Poland, and the United States, respectively, are presented. Environmental influences (mainly temperature) and validation by load tests are discussed.
This article presents a unique method of installing a special type of embedded ultrasonic transducers inside a 36-m-long section of an old bridge in Germany. A small-scale load test was carried out by a 16 ton truck to study the temperature and load influence on the bridge, as well as the performance of the embedded transducers. Ultrasonic coda wave interferometry technique, which has high sensitivity in detecting subtle changes in a heterogeneous medium, was used for the data evaluation and interpretation. The separation of two main influence factors (load effect and temperature variation) is studied, and future applications of wave velocity variation rate Φ for structural health condition estimation are discussed. As a preliminary research stage, the installation method and the performance of the ultrasonic transducer are recognized. Load- and temperature-induced weak wave velocity variations are successfully detected with a high resolution of 10−4%. The feasibility of the whole system for long-term structural health monitoring is considered, and further research is planned.
The ‘Gänstorbrücke’ bridge between the cities of Ulm and Neu-Ulm is one of the best-monitored bridges all over Germany. In addition to an already active bride monitoring system, we have equipped the bridge with 30 ultrasonic transducers to explore the monitoring possibilities at an in-service large-scale reinforced concrete structure with continuous active ultrasonic measurements. The monitoring system is based on the detection of small changes in the entire signal, especially the multiply scattered parts of the recording, the so-called coda. Applying Coda Wave Interferometry (CWI), subtle changes in the signal can be detected and related to changing velocities in the area between source and receiver. A comparison of the results from coda wave interferometry with the strain measurements of the permanent monitoring system shows a correlation between strain measurements and CWI results. We discuss the challenges of changing environmental conditions, pose for interpretation of the results, and highlight the advantages of embedded versus externally attached ultrasonic transducers in permanent bridge monitoring, especially when coda wave interferometry is applied.
Moisture ingress is one of major damaging factors for masonry buildings. As the complex resistivity (CR) is sensitive to textural properties as well as to the pore fluid chemistry of wet porous media, its non-destructive application can provide helpful information for conservators. In a comprehensive laboratory study it has been shown that CR might even be able to distinguish between salt content and saturation degree in only one measurement. The combined use of electrical and electromagnetic measurement techniques in two field-scale flooding experiments has shown some unexpected differences. Possible reasons are discussed and it is shown that bringing together the information of both methods leads to a clearer picture.