Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (23)
- Beitrag zu einem Tagungsband (4)
- Sonstiges (4)
- Beitrag zu einem Sammelband (3)
- Vortrag (2)
- Posterpräsentation (1)
- Forschungsbericht (1)
Schlagworte
- Gold (6)
- BAMline (4)
- Micro-PIXE (4)
- XANES (4)
- Archaeometry (3)
- Gefahrgut (3)
- Gefahrstoff (3)
- Micro-SR-XRF (3)
- Prüfmethode (3)
- Qualitätssicherung (3)
Organisationseinheit der BAM
- 6 Materialchemie (9)
- 6.3 Strukturanalytik (8)
- 2 Prozess- und Anlagensicherheit (2)
- 8 Zerstörungsfreie Prüfung (2)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.2 Biophotonik (1)
- 2.0 Abteilungsleitung und andere (1)
- 2.1 Sicherheit von Energieträgern (1)
- 4 Material und Umwelt (1)
Eingeladener Vortrag
- nein (2)
A comparative study on the performance of digital detector systems for high energy applications
(2014)
For cast components reaching or exceeding total material thicknesses of 150mm, high energy sources such as linear accelerators or Betatrons are required in order to obtain reasonable exposure times. In this study, the performance of digital detector systems, involving imaging plates (IP) and digital detector arrays (DDA), was evaluated with respect to the testing class B requirements as formulated in the standard EN ISO 17636-2. As a reference, traditional radiographic film and a Cobalt-60 source was used. With film exposures, testing class B was achieved with Co-60 and Betatron (7.5 MV) at longer exposure times. The preliminary results show that the testing class B was not obtained with the examined digital detector arrays (DDA) and the high resolution imaging plates (IP) , even at 40, 60 and 80 minutes exposure time with a 7.5 MV Betatron. Class A was achieved using high resolution imaging plates with optimized metal filters between object and IPs and a high resolution DDA with intermediate Cu filters. Class A was also achieved applying a DDA with lower basic spatial resolution than required by Table B.13 of EN ISO 17636-2, but using the compensation principle as described in this standard. The next generation of digital detector arrays might potentially be able to obtain class B performance with the expected spatial resolution and sensitivity improvements.
Shading Effects in SR-TXRF: Calculations and Experimental Visualization using a Color X-ray Camera
(2014)
Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und -prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS).
Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung abzielen und nicht auf Leistungstests.
Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS).
Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests.
Efficient Near UV excited materials (350<λ<400 nm) responding with green line emission are sparse in comparison to higher energy UV excited emitters (λ<350 nm), while corresponding red line emitters are more abundant, albeit typically also restricted to excitation wavelengths below 400 nm. This situation is disadvantageous for several important actual and potential applications. Among these, excitation with high power UV-LEDs and laser diodes are of particular interest. Here we present results on green emitting YBO3:Ce, Tb, which can be excited with 370–380 nm radiation at quantum efficiencies of up to 60% and decay times in excess of 2 ms. Moreover, as powderous phosphors typically require stable matrices to be hosted in, we investigated low melting, lead- and fluoride-free glasses for their capability to accommodate the phosphor and yet retain its optical properties. In these, we even observed an increase of the quantum efficiencies of up to 70% at decay times approaching 3 ms. Finally, we characterized the thermal quenching behavior, which showed a clear advantage of the phosphors in glassy matrices.
Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS).
Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests.
"Ullmann's Encyclopedia of Industrial Chemistry" is the benchmark reference in chemistry and chemical and life science engineering, covering inorganic and organic chemicals, advanced materials, pharmaceuticals, polymers and plastics, metals and alloys, biotechnology and biotechnological products, food chemistry, process engineering and unit operations, analytical methods, environmental protection, and much more.
The present article is part of the topic collection "Environmental Protection and Industrial Safety". It covers plant and process safety, focusing on hazardous materials and process conditions.
DICONDE in der ZfP
(2023)
DICONDE (Digital Imaging and Communication in Non-Destructive Evaluation) ist ein offener internationaler Standard zur Speicherung und zum Austausch industrieller Prüfdaten und prozessbezogener Informationen. Der DICONDE-Standard definiert sowohl die Semantik für eine strukturierte Speicherung von Daten als auch die netzwerkbasierte Kommunikation zwischen zwei Endpunkten. Damit lassen sich viele Vorgänge von Prüfprozessen digital und sicher abbilden und gleichzeitig normative Anforderungen wie eine Rückführbarkeit zum Prüfer und Prüfobjekt sowie eine Reproduzierbarkeit von Prüfergebnissen erfüllen.
DICONDE (Digital Imaging and Communication in Non-Destructive Testing) is an open international standard for storing and exchanging industrial test data and process-related information. The DICONDE standard defines both the semantics for structured storage of data and the network-based communication between two endpoints. This allows many test processes to be mapped digitally and securely, while at the same time meeting normative requirements such as traceability to the tester and test object and reproducibility of test results.
EXAFS analysis of pure elements, binary and ternary equiatomic refractory alloys within the Nb-Zr-Ti-Hf- Ta system is performed at the Nb and Zr K-edges to analyze the evolution of the chemical local environ- ment and the lattice distortion. A good mixing of the elements is found at the atomic scale. For some compounds, a distribution of distances between the central atom and its neighbors suggests a distortion of the structure. Finally, analysis of the Debye-Waller parameters shows some correlation with the lat- tice distortion parameter δ², and allows to quantify experimentally the static disorder in medium entropy alloys.