Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (9)
- Beitrag zu einem Sammelband (4)
- Vortrag (4)
- Beitrag zu einem Tagungsband (1)
- Corrigendum (1)
- Sonstiges (1)
Schlagworte
- Sicherheitstechnik (3)
- Deflagration (2)
- Detonation (2)
- Mikroreaktionstechnik (2)
- Mikroreaktor (2)
- Mikroreaktoren (2)
- Adsorbable organically bound fluorine (AOF) (1)
- Agricultural mycology (1)
- Analytical methods (1)
- Arbeitsschutz (1)
Organisationseinheit der BAM
- 4 Material und Umwelt (3)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.1 Anorganische Spurenanalytik (2)
- 4.3 Schadstofftransfer und Umwelttechnologien (2)
- 4.0 Abteilungsleitung und andere (1)
- 7 Bauwerkssicherheit (1)
- 7.2 Ingenieurbau (1)
- 8 Zerstörungsfreie Prüfung (1)
- 8.0 Abteilungsleitung und andere (1)
Eingeladener Vortrag
- nein (4)
An assessment of the elastic-plastic buckling limit state for multi-strake wind turbine support towers poses a particular challenge for the modern finite element analyst, who must competently navigate numerous modelling choices related to the tug-of-war between meshing and computational cost, the use of solvers that are robust to highly nonlinear behaviour, the potential for multiple near-simultaneously critical failure locations, the complex issue of imperfection sensitivity and finally the interpretation of the data into a safe and economic design.
This paper reports on an international ‘round-robin’ exercise conducted in 2022 aiming to take stock of the computational shell buckling expertise around the world which attracted 29 submissions. Participants were asked to perform analyses of increasing complexity on a standardised benchmark of an 8-MW multi-strake steel wind turbine support tower segment, from a linear elastic stress analysis to a linear bifurcation analysis to a geometrically and materially nonlinear buckling analysis with imperfections. The results are a showcase of the significant shell buckling expertise now available in both industry and academia.
This paper is the first of a pair. The second paper presents a detailed reference solution to the benchmark, including an illustration of the Eurocode-compliant calibration of two important imperfection forms.
A method for the determination of safety properties for micro reactors and micro structured components is presented.
Micro structured reactors are not inherently safe but the range of safe operating conditions of micro reactors are
extended since the explosion region is reduced. The λ/3 rule was demonstrated to be applicable to micro scale
tubes for stoichiometric mixtures of ethane–oxygen and ethane–nitrous oxide. Furthermore first results from an investigation concerning detonation propagation through a micro reactor of non-ideal geometry are shown. Initial
pressure investigated is ranging from low pressure up to 100 kPa.
Es wird eine Methode zur sicherheitstechnischen Untersuchung von Mikroreaktoren und mikrostrukturierten Komponenten, die im Explosionsbereich betrieben werden sollen, vorgestellt. Mikrostrukturierte Reaktoren sind nicht inhärent sicher, wenngleich der Bereich der sicheren Betriebsbedingungen gegenüber konventionellen Reaktoren erweitert ist. Der Explosionsbereich kann durch die Mikrostrukturen eingeengt werden. Am Beispiel von Ethylen/Sauerstoff-Gemischen und Ethylen/N2O-Gemischen wird hinsichtlich der Ausbreitung von Detonationen durch Kapillarrohre gezeigt, dass die sogenannte λ/3-Regel angewandt werden kann. Darüber hinaus werden erste Ergebnisse der Untersuchung der Ausbreitung von Explosionen durch einen Mikroreaktor mit rechteckigem Strömungskanal vorgestellt.
Are micro reactors inherently safe? - An investigation of gas phase explosion propagation limits
(2010)
The interaction of microplastics with freshwater biota and their interaction with other stressors is still not very well understood. Therefore, we investigated the ingestion, excretion and toxicity of microplastics in the freshwater gastropod Lymnaea stagnalis.
MP ingestion was analyzed as tissues levels in L. stagnalis after 6–96 h of exposure to 5–90 μm spherical polystyrene (PS) microplastics. To understand the excretion, tissue levels were determined after 24 h of exposure followed by a 12 h–7 d depuration period. To assess the toxicity, snails were exposed for 28 d to irregular PS microplastics (<63 μm, 6.4–100,000 particles mL−1), both alone and in combination with copper as additional stressor. To compare the toxicity of natural and synthetic particles, we also included diatomite particles. Microplastics ingestion and excretion significantly depended on the particle size and the exposure/depuration duration. An exposure to irregular PS had no effect on survival, reproduction, energy reserves and oxidative stress. However, we observed slight effects on immune cell phagocytosis. Exposure to microplastics did not exacerbate the reproductive toxicity of copper. In addition, there was no pronounced difference between the effects of microplastics and diatomite. The tolerance towards microplastics may originate from an adaptation of L. stagnalis to particle-rich environments or a general stress resilience. In conclusion, despite high uptake rates, PS fragments do not appear to be a relevant stressor for stress tolerant freshwater gastropods considering current environmental levels of microplastics.
Stress is a normal part of life for fungi, which can survive in environments considered inhospitable or hostile for other organisms. Due to the ability of fungi to respond to, survive in, and transform the environment, even under severe stresses, many researchers are exploring the mechanisms that enable fungi to adapt to stress. The International Symposium on Fungal Stress (ISFUS) brings together leading scientists from around the world who research fungal stress. This article discusses presentations given at the third ISFUS, held in Sao Jose dos Campos, Sao Paulo, Brazil in 2019, thereby summarizing the state-of-the-art knowledge on fungal stress, a field that includes microbiology, agriculture, ecology, biotechnology, medicine, and astrobiology.
Der Frequenzbereich der Terahertzwellen liegt im elektromagnetischen Spektrum zwischen den Mikrowellen und dem infraroten Licht – also etwa im Bereich von 0,1 bis 10 Terahertz (THz). Der VDI-Statusreport „Terahertzsysteme und Anwendungen“ stellt die unterschiedlichen Konzepte für Terahertzsysteme vor und zeigt Anwendungsbeispiele, bei denen die Terahertztechnik erfolgreich eingesetzt wird. Umfangreiche Literaturangaben ermöglichen eine intensivere Beschäftigung mit allen Themen des VDI-Statusreports.
The suitability of common analytical methods for the determination of active substances from wood preservatives in aged wood samples was investigated during an interlaboratory study. Permethrin, propiconazole and tebuconazole were quantified in 1.5 and 8 year-old wood samples by gas chromatography and liquid chromatography. Generally, the applied Methods yielded reliable results for these samples. However, wood components can coelute with propiconazole and tebuconazole during liquid chromatography. Optimization of separation might be required if UV detection is applied.
The article “Determination of organically bound fluorine sum parameters in river water samples - Comparison of combustion ion chromatography (CIC) and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS)” was originally published Online First without Open Access. After publication in volume 413, issue 1, page 103–115 of the journal “Analytical and bioanalytical chemistry”, the authors decided to opt for Open Choice and to make the article an Open Access publication. Therefore, the copyright of the article has been changed to © The Author(s) 2021 and the article is forthwith distributed under the terms of the Creative Commons Attribution 4.0 International License.
In this study, we compare combustion ion chromatography (CIC) and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) with respect to their applicability for determining organically Bound fluorine sum parameters. Extractable (EOF) and adsorbable (AOF) organically bound fluorine as well as total fluorine (TF) were measured in samples fromriver Spree in Berlin, Germany, to reveal the advantages and disadvantages of the two techniques used as well as the two established fluorine sum Parameters AOF and EOF. TF concentrations determined via HR-CS-GFMAS and CIC were comparable between 148 and 270 μg/L. On average, AOF concentrations were higher than EOF concentrations, with AOF making up 0.14–0.81% of TF (determined using CIC) and EOF 0.04–0.28% of TF (determined using HR-CSGFMAS).
The results obtained by the two independent methods were in good agreement. It turned out that HR-CS-GFMAS is a more sensitive and precise method for fluorine analysis compared to CIC. EOF and AOF are comparable tools in Risk evaluation for the emerging pollutants per- and polyfluorinated alkyl substances; however, EOF is much faster to conduct.