Im Rahmen des EMPIR-Projektes NanoXSpot (Nanometre X-Ray Focal Spot Measurement) werden rückführbare Messverfahren zur Bestimmung der Brennfleckgröße und -form von Röntgenröhren mit Submikrometerauflösung (100 nm – 20 µm) entwickelt, die die Grundlage für die Erarbeitung eines Standardentwurfes bilden. Der Standardentwurf wird bei CEN TC 138 (Non-destructive testing) WG 1 (Radiographic testing) eingereicht und mit ISO und ASTM harmonisiert. Zur Untersuchung der entwickelten Methoden (Brennfleck-CT, Fit-Prozedur für Strichgruppenkörper) und des im Projekt NanoXSpot neu entworfenen Testkörpers, NxS, wurde ein Ringversuch durchgeführt. Dabei wurde sowohl der angestrebte Überlappungsbereich mit EN 12543 Teil 5 (Messung der effektiven Brennfleckgröße von Mini- und Mikrofokus-Röntgenröhren) und ASTM E 2903 (Standard Test Method for Measurement of the Effective Focal Spot Size of Mini and Micro Focus X-ray Tubes) für Brennflecke >5 µm als auch Brennflecke <5 µm untersucht. Im Mittelpunkt standen dabei Stabilität und Wiederholbarkeit der entwickelten Methoden zur Bestimmung der Brennfleckgröße. In diesem Beitrag werden die Ergebnisse des durchgeführten Ringversuches vorgestellt und diskutiert, um Schlussfolgerungen und Empfehlungen für die Vorbereitung eines erweiterten Ringversuchs mit Partnern und Stakeholdern abzuleiten.
Im Rahmen des EMPIR-Projektes NanoXSpot (Nanometre X-ray Focal Spot Measurement) werden rückführbare Messverfahren zur Bestimmung der Brennfleckgröße und -form von Röntgenröhren im Bereich von 100 nm bis 10 mm entwickelt, welche die Grundlage für die Erarbeitung mehrerer Normentwürfe bilden. Diese werden 2022 parallel bei ISO TC 135 (NDT) SC 5 (RT) und CEN TC 138 (NDT) WG 1 (RT) eingereicht. Entsprechende Normen werden auch bei ASTM vorgestellt. Die Norm EN 12543-4 (Kantenmethode) wird umgeschrieben für die Messung von Brennflecken von 1 μm – 10 mm durch Auswertung von Loch- oder Scheibenaufnahmen. Der im Rahmen des NanoXSpot-Projektes neu entwickelte NxS-Testkörper ist geeignet für den Bereich von 1 μm – 100 μm. Von 100 μm bis 10 mm können ASTM-Lochtestkörper verwendet werden, die bereits bei ASTM E 1165 beschrieben sind. Neu ist die Anwendung eines CT-Algorithmus zur Rekonstruktion der Brennflecke, um Lochblenden-basierte Brennfleckkameras, insbesondere im Bereich unter 100 μm, zu ersetzen. Ein neuer Normteil, EN 12543-6, wurde entworfen, um die Brennfleckmessung im Bereich 100 nm – 20 μm mit hoher Genauigkeit zu ermöglichen. Verschiedene Strichgruppen-Testkörper kommen hier zum Einsatz. Das sind die JIMAPrüfkörper, ein neuer Hochkontrast-Strichgruppentestkörper von YXLON (HiCo) und der neu entwickelte Testkörper NxS. Diese werden vorgestellt. Die Messprozedur für Röhrenhersteller wird auf einer numerischen Fit-Prozedur basieren, die über einen Ringversuch im Projekt validiert wurde. Beide Normen benötigen numerische Auswertealgorithmen zur korrekten Anwendung, die als kommerzielle Software und Public Domain – Software verfügbar gemacht werden. Es wird über die zu erwartenden Standardprozeduren und die erforderliche Hardware zur Anwendung der Normen informiert.
Im Rahmen des EMPIR-Projektes NanoXSpot (Nanometre X-ray Focal Spot Measurement) werden rückführbare Messverfahren zur Bestimmung der Brennfleckgröße und -form von Röntgenröhren im Bereich von 100 nm bis 10 mm entwickelt, welche die Grundlage für die Erarbeitung mehrerer Normentwürfe bilden. Diese werden 2022 parallel bei ISO TC 135 (NDT) SC 5 (RT) und CEN TC 138 (NDT) WG 1 (RT) eingereicht. Entsprechende Normen werden auch bei ASTM vorgestellt. Die Norm EN 12543-4 (Kantenmethode) wird umgeschrieben für die Messung von Brennflecken von 1 μm – 10 mm durch Auswertung von Loch- oder Scheibenaufnahmen. Der im Rahmen des NanoXSpot-Projektes neu entwickelte NxS-Testkörper ist geeignet für den Bereich von 1 μm – 100 μm. Von 100 μm bis 10 mm können ASTM-Lochtestkörper verwendet werden, die bereits bei ASTM E 1165 beschrieben sind. Neu ist die Anwendung eines CT-Algorithmus zur Rekonstruktion der Brennflecke, um Lochblenden-basierte Brennfleckkameras, insbesondere im Bereich unter 100 μm, zu ersetzen. Ein neuer Normteil, EN 12543-6, wurde entworfen, um die Brennfleckmessung im Bereich 100 nm – 20 μm mit hoher Genauigkeit zu ermöglichen.
Verschiedene Strichgruppen-Testkörper kommen hier zum Einsatz. Das sind die JIMAPrüfkörper, ein neuer Hochkontrast-Strichgruppentestkörper von YXLON (HiCo) und der neu entwickelte Testkörper NxS. Diese werden vorgestellt. Die Messprozedur für Röhrenhersteller wird auf einer numerischen Fit-Prozedur basieren, die über einen Ringversuch im Projekt validiert wurde. Beide Normen benötigen numerische Auswertealgorithmen zur korrekten Anwendung, die als kommerzielle Software und Public Domain – Software verfügbar gemacht werden. Es wird über die zu erwartenden Standardprozeduren und die erforderliche Hardware zur Anwendung der Normen informiert.
Im Rahmen des EMPIR-Projektes NanoXSpot (Nanometre X-Ray Focal Spot Measurement) werden rückführbare Messverfahren zur Bestimmung der Brennfleckgröße und -form von Röntgenröhren mit Submikrometerauflösung (100 nm – 20 μm) entwickelt, die die Grundlage für die Erarbeitung eines Standardentwurfes bilden. Der Standardentwurf wird bei CEN TC 138 (Non-destructive testing) WG 1 (Radiographic testing) eingereicht und mit ISO und ASTM harmonisiert. Zur Untersuchung der entwickelten Methoden (Brennfleck-CT, Fit-Prozedur für Strichgruppenkörper) und des im Projekt NanoXSpot neu entworfenen Testkörpers, NxS, wurde ein Ringversuch durchgeführt. Dabei wurde sowohl der angestrebte Überlappungsbereich mit EN 12543 Teil 5 (Messung der effektiven Brennfleckgröße von Mini- und Mikrofokus-Röntgenröhren) und ASTM E 2903 (Standard Test Method for Measurement of the Effective Focal Spot Size of Mini and Micro Focus X-ray Tubes) für Brennflecke >5 μm als auch Brennflecke <5 μm untersucht. Im Mittelpunkt standen dabei Stabilität und Wiederholbarkeit der entwickelten Methoden zur Bestimmung der Brennfleckgröße. In diesem Beitrag werden die Ergebnisse des durchgeführten Ringversuches vorgestellt und diskutiert, um Schlussfolgerungen und Empfehlungen für die Vorbereitung eines erweiterten Ringversuchs mit Partnern und Stakeholdern abzuleiten.
This sequence of X-Ray images shows how one of the most common Italian moka pots actually work! The sequence starts with a completely prepared moka pot (water in the bottom part, coffee in the middle and hot plate on). During the process the water starts to boil and the steam pressure pushes the hot water through the coffee into the bassin at the top of the pot.
This video sequence and additional explanations can also be found on Wikipedia.
X-Ray computed tomography (XCT) scan of 11 individual metallic powder particles, made of (Mn,Fe)2(P,Si) alloy. The data set consists of 4 single XCT scans which have been stitched together [3] after reconstruction. The powder material is an (Mn,Fe)2(P,Si) alloy with an average density of 6.4 g/cm³. The particle size range is about 100 - 150 µm with equivalent pore diameters up to 75 µm. The powder and the metallic alloy are described in detail in [1, 2].
Im Europäischen EMPIR-Projekt „NanoXSpot“ (Measurement of the focal spot size of Xray tubes with spot sizes down to 100 nm) werden neue Messmethoden für Brennflecke von Röntgenröhren entwickelt. Teil des Projektes ist die Entwicklung eines zur Lochkameramethode äquivalenten Messverfahrens für kleine Brennflecke. ASTM E 1165-20, Annex A, beschreibt die Bestimmung von Brennfleckgrößen aus Kantenprofilen von Lochaufnahmen für Röntgenröhren mit Brennflecken > 50 μm. Es wurde bereits vorgeschlagen über die Analyse der richtungsabhängigen Kantenunschärfe einer Lochblende und anschließender CT-Rekonstruktion die Intensitätsverteilung des Brennflecks äquivalent zur Lochkameraaufnahme zu berechnen. Die Lochkameramethode, wie in EN 12543-2 und ASTM E 1165-20 beschrieben, ist im unteren Größenbereich für Mikrofokusröhren nicht geeignet, da Pinholes < 10 μm schwer zu fertigen sind und lange Belichtungszeiten erwartet werden. Mit Hilfe exakt gefertigter Lochblenden sowie strukturierter Targets mit
konvergierenden Strukturen wird der Bereich mit der Single-Shot-CT-Methode auf die Messung von Mikrofokusröhren, alternativ zur Vermessung von Kanten oder Strichgruppenkörpern, erweitert. Die rekonstruierten Brennfleckformen werden mit Kantenund Lochkameraaufnahmen quantitativ verglichen, um die Messgenauigkeit zu bewerten.
Außerdem werden CNR und Messzeit bestimmt, um die Wirtschaftlichkeit der Verfahren zu bewerten.
The objective of this work is to find a method that describes the degree of damage from an impact experiment. This experiment was performed on Composite Pressure Vessels (CPV) in order to find the correlation of impact damage to the residual burst pressure. Computed Tomography (CT) approach was used to capture the before and after impact condition of the CPVs. The Wasserstein function was used to calculate how much the after impact image has differed from the original one. In the end, a good correlation was obtained to the residual burst pressure.
Diese Arbeit beschäftigt sich mit den Eigenschaften der photonenzählenden und spektralauflösenden Detektortechnik und möglichen Anwendungsgebieten in der zerstörungsfreien Prüfung. Dabei wurden konventionelle und photonenzählende Detektortechniken hinsichtlich der Bildqualität und Anwendbarkeit bei unterschiedlichen Prüfaufgaben verglichen und untersucht, inwiefern sich die Energieschwellwertsetzung auf die erreichbare Bildqualität und eine Materialdiskriminierbarkeit bei verschiedenen radiographischen Verfahren auswirkt.
Anhand von Anwendungsbeispielen wurden diese Eigenschaften und deren Auswirkung auf das Messergebnis analysiert. Neben der Radiographie wurden auch dreidimensionale Verfahren wie CT und Laminographie berücksichtigt.
Als eine der wichtigsten Eigenschaften der photonenzählenden Detektortechnik wurden zunächst die Energieauflösung des photonenzählenden Detektors und die Homogenität der Energieantwort über größere Detektorbereiche bestimmt. Dabei stellte sich heraus, dass die Energieauflösung eines abgegrenzten Detektorbereichs ca. 32 % bei 60 keV beträgt und die Streuung in der Energieantwort der einzelnen Detektorbereiche ca. 12 % ausmacht, woraus sich eine Gesamtunsicherheit in der spektralen Detektorantwort von ca. 44 % ergibt. Die geringe Energieauflösung und das stark heterogene Verhalten der Detektorbereiche ergeben sich vor allem aus der Detektorelektronik, welche nur eine globale Energieschwellwertsetzung zulässt.
Trotz dieser Einschränkungen konnte demonstriert werden, dass auch konventionelle radiographische Verfahren, wie Radiographie oder CT, vom Einsatz der photonenzählenden Technik profitieren. So ist es mit dieser Technik möglich, bei sehr geringen Dosisleistungen (z.B. aufgrund der Durchstrahlung großer Wandstärken von dichten Materialien) noch sehr gute Bildqualitäten zu erreichen. Die hohe Dynamik und Kontrastempfindlichkeit dieser Technik begünstigen die Inspektion von Leichtbauwerkstoffen wie Faserverbunde, was anhand von Vergleichen mit herkömmlicher Detektortechnik und anderen ZfP-Verfahren gezeigt werden konnte. Daneben konnte durch den Einsatz der Energieschwellwertsetzung der Einfluss von nicht bildzeichnender Streustrahlung im Röntgenbild um bis zu 20 % reduziert werden. Die Auswirkungen von Aufhärtungseffekten in der CT konnten sogar um bis zu Faktor 1 000 (in der mittleren quadratischen Abweichung), im Vergleich zu herkömmlicher Detektortechnik, reduziert werden.
Der Einsatz von photonenzählender Detektortechnik mit Röntgenblitzröhren ist hingegen nicht sinnvoll, da aufgrund der hohen Photonendichte pro Puls und einer endlichen Totzeit des Detektors in der Größenordnung der Pulsbreite eines Blitzes nur ein geringes Signal detektiert werden kann.
Im Hinblick auf eine Materialdiskriminierbarkeit konnte demonstriert werden, dass im Fall einer Radiographie anhand der Energieschwellwertsetzung im Detektor eine materialstärkenunabhängige Diskriminierung zwischen zwei Materialien (hier: Al und Fe) erzielt werden kann. Unter Einsatz mehrerer Energiefenster und eines Verfahrens der explorativen und multivariaten Datenanalyse konnte eine materialaufgelöste CT eines Multi-Material-Phantoms erreicht werden, wobei die Schwächungskoeffizienten der enthaltenen Materialien im relevanten Energieberiech teilweise sehr dicht beieinander lagen.
Neben Radiographie und CT wurde auch die Möglichkeit einer materialaufgelösten Laminographie am Beispiel eines glasfaserverstärkten Rotorblatts untersucht. Anhand der Energieschwellwertsetzung war nicht nur eine eindeutige Trennung der Glasfasern von der Epoxidharzmatrix möglich, sondern auch eine signifikante Reduzierung der durch die Laminographie entstandenen Artefakte. Der damit verbundene Gewinn an Information führt zu einer verbesserten Aussagefähigkeit des Untersuchungsergebnisses, was letztendlich eine gesteigerte Betriebssicherheit zur Folge hat.