Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (43) (entfernen)
Referierte Publikation
- nein (43)
Schlagworte
- Bauprodukte (5)
- Prozessanalytik (5)
- Raman spectroscopy (5)
- Emissionen (4)
- Geruch (4)
- Process analytical technology (4)
- Hydroformylation (3)
- Perceived air quality (3)
- Reaction monitoring (3)
- VOC (3)
- Absorption (2)
- AgBB-Schema (2)
- Bewertung Emissionen (2)
- NDT (2)
- Normung (2)
- Odour (2)
- POD (2)
- Prozess-Spektroskopie (2)
- Reliability (2)
- Standardisation (2)
- UT (2)
- 4-Eye Principle (1)
- Acceptability (1)
- Additive Fertigung (AM) (1)
- Advanced process control (1)
- AgBB (1)
- AgBB-Scheme (1)
- Antioxidant (1)
- Automation Bias (1)
- Axles (1)
- Barium and calcium silicate plass powders (1)
- CCS (1)
- CMAS - Calcium-Magnesium-Aluminiumsilikat (1)
- CO2 (1)
- CO2-Absorption (1)
- CWA07 (1)
- Carbon capture (1)
- Carbon dioxide (1)
- Chemometrics (1)
- Computertomographie (1)
- Construction product (1)
- Copper canister weld (1)
- Cordierite (1)
- Crystal growth (1)
- Deep repository (1)
- Degassing (1)
- Degradation (1)
- Demining (1)
- Detection technology (1)
- Diopside (1)
- Durability (1)
- EFNDT Arbeitsgruppe 5 (1)
- Emission test (1)
- Emission tests (1)
- Emissionsmessung (1)
- Emulsions (1)
- Emuslions (1)
- Encapsulation (1)
- Evaluation (1)
- Eye Tracking (1)
- Failure Modes and Effects Analysis (FMEA) (1)
- Flooring material (1)
- Foaming (1)
- Gefahrstoffe (1)
- Gefahrstoffnachweis (1)
- Geosynthetic (1)
- Glass (1)
- Handheld terahertz spectrometer (1)
- Hazardous and toxic gasses and vapours (1)
- Human Factors (1)
- Human factors (1)
- Hydroformylierung (1)
- In-Service Inspection (ISI) (1)
- Kammerverfahren (1)
- Kontrollen (1)
- Label (1)
- Labelling (1)
- Labelling systems (1)
- Liquid explosives (1)
- Material labelling (1)
- Messmethoden (1)
- Metal detectors (1)
- Microemulsions (1)
- Mizellen (1)
- Multi-gas sensor (1)
- NMR-Spektroskopie (1)
- Nuclear Power Plants (1)
- Nuclear Waste Storage (1)
- Numerische Simulation (1)
- Odor (1)
- Odour evaluation (1)
- Odour intensity (1)
- Odour labelling (1)
- Online NMR Spectroscopy (1)
- Online NMR spectroscopy (1)
- Online Raman Spectroscopy (1)
- Perceived air-quality (1)
- Perceived intensity (1)
- Perceived odour intensity (1)
- Polyamid 12 (1)
- Process Analytical Technology (1)
- Profiling (1)
- Qualifizierung (1)
- Qualitätssicherung (1)
- Quantitative NMR-Spektroskopie (1)
- RAL UZ (1)
- ROC diagrams (1)
- RT (1)
- Railway (1)
- Raman-Spektroskopie (1)
- Reaction Monitoring (1)
- Reliability tests (1)
- Röntgen-Refraktion (1)
- Röntgenrefraktion (1)
- SXRR - Synchrotron X-ray Refraction Radiography (1)
- Sensor system (1)
- Sensor systems (1)
- Sensory evaluation (1)
- Sensory tests (1)
- Sicherheit (1)
- Silicate glass powders (1)
- Sintering (1)
- Spent nuclear fuel (1)
- TBC - Thermal barrier coatings (1)
- Test and evaluation (1)
- Test procedure (1)
- Threats other than explosives (1)
- Time Pressure (1)
- Ultraschallprüfung (1)
- Ultrasonic measurement and modelling (1)
- VOC emission (1)
- VOC-emission (1)
- VOCs (1)
- Verbundwerkstoffe (1)
- Warfare substances (1)
- Weathering (1)
- Zahnstifte (1)
- Zeitdruck (1)
- Zerstörungsfreie Prüfung (1)
- ZfP (1)
- desorption control (1)
- sensory evaluation of building materials and rooms (1)
Organisationseinheit der BAM
Currently at Deutsche Bahn (DB) ultrasonic inspections in maintenance procedures for wheelset axles with a bore hole are, to the greatest possible extent, carried out using automated ultrasonic inspection system. Although the acceptance levels are in accordance with DIN 27201 part 7, the testing results have shown in recent years that in the case of true indications, the effective defect sizes were far below the level of acceptance. Due to this experience it can be assumed that the automated ultrasonic inspection systems are testing substantially more sensitively than required. This increased sensitivity leads to an increase in false indications, generally resulting in the unnecessary demounting of wheelsets. In Research cooperation between Federal Institute for Materials Research and Testing (BAM) and DB the effective flaw detection sensitivity of existing automated ultrasonic inspection system will be determined and the true/false indication ratio optimised. Through systematic investigations with the Probability of Detection method on the existing automated ultrasonic inspection system the results could be directly applied to the optimisation of existing ultrasonic inspections of wheelset axles with a bore hole in maintenance procedures and the level of reliability can be considerably increased.
Normung und Standardisierung in der zerstörungsfreien Prüfung finden auf nationaler, europäischer und internationaler Ebene statt. Die Übernahme von Leitungsfunktionen in diesen Gremien erzeugt die Möglichkeit der Steuerung von Themen und Inhalten der relevanten Normen. Das persönliche Engagement der Fachexpert*innen in den nationalen Gremien und den europäischen und internationalen Arbeitsgruppen ist ein zusätzlicher Faktor für die inhaltliche Korrektheit und die inhaltliche Ausrichtung der Norm. Denn wer nicht normt, wird genormt und muss letztlich Normen anwenden, die andere entsprechend ihrer eigenen Interessen gestaltet haben. Voraussetzung für die Teilnahme in europäischen und internationalen Normungsgremien ist die Mitwirkung in den entsprechenden DINSpiegelgremien, welche die europäischen (CEN) und internationalen (ISO) Aktivitäten spiegeln und die Fachexpert*innen für die Mitarbeit autorisieren.
Auf internationaler Ebene findet die Normungsarbeit in den technischen Komitees ISO/TC 135 “Non-destructive testing” und ISO/TC 44/SC 5 “Testing and inspection of welds” und ihren Arbeitsgruppen statt. Das europäische Pendant ist das CEN/TC 138 “Zerstörungsfreie Prüfverfahren” mit seinen Arbeitsgremien. Die DINSpiegelgremien sind für die deutsche Mitarbeit in diesen Gremien und die inhaltliche Bewertung der Norm-Entwürfe zuständig.
The Collaborative Research Center InPROMPT aims to establish a novel process concept for the hydroformylation of long-chained olefins, using a rhodium complex as catalyst in the presence of syngas. Recently, the hydroformylation in micro-emulsions, which allows for the efficient recycling of the expensive rhodium catalyst, was found to be feasible. However, the temperature and concentration sensitive multi-phase system demands a continuous observation of the reaction to achieve an operational and economically feasible plant operation. For that purpose, we tested the potential of both NMR and Raman spectroscopy for process control assistance. The lab-scale experiments were supported by sampling for off-line GC-analysis as reference analytics. The results of the NMR experiments will be part of another contribution.
The project InPROMPT aims to establish a robust hydroformylation reaction process of the alkene n-dodecene to the aldehyde n-tridecanal using a rhodium complex as catalyst in the presence of syngas. This industrial relevant production process demands further research for optimization and expansion. For that purpose, the fiber optic coupled probe of a process Raman spectrometer is directly introduced in the product stream, which enables the recording of spectra within short control intervals.
The reliability investigations are dedicated to throw light on the performance of the NDE system with respect to the required aim. This is especially of interest when it is looked for life damaging objects in the case of mine seeking and when it is even more difficult to distinguish between the different suppliers of methods concerning their actual capability.
In accordance with the conception of EFNDT WG5 and CEN BT 126 CW 07 the authors have the aim to transfer the knowledge in reliability measurement of NDE systems to the reliability measurement of mine detection systems. For this the three basic ways to investigate the reliability of NDE signals will be described. The first way of investigation, the performance demonstration, is preferred e.g. in the US American nuclear power industry. This is an integral consideration of the non destructive test as a system where the whole NDE system is packed in a black box and only the input in terms of the real existing flaws in the component is considered and compared to the output in terms of the indications of the human inspector or of the automated system. The second - the European tradition relies on a standardized description of physical/technical parameters of the NDE system which are preconditions for successful system performance. The third approach - the modular conception - is a marriage of both: The signal chain is cut into main modules.
Each module is assessed in a most appropriate individual way e.g. via modeling calculations. The single results are joint together according to the reliability theory of systems where the reliability of the total system is composed of the reliability of the subsystems. Separating criteria for the system were proposed through a reliability formula developed during a series of European-American workshops on NDE reliability. A further essential parameter especially for demining systems are the repeatability and reproducibility. Their affect on the reliability and its scatter will be investigated. Examples for the ROC/POD approach in terms of the investigation of the reliability of ultrasonic manual testing and for first attempts for the reliability investigation of demining data will be presented.
It will be strongly recommended to apply the ROC/POD and Modular Conceptions to the assessment and optimization of mine seeking systems.
Proposals for Performance Demonstration and Modular Reliability Assessment for Humanitarian Demining
(2003)
For safe and reliable demining it is necessary to determine the actual true performance of mine searching equipment in detecting mines. The subject to detect a hidden subject by penetrating physical interaction with the target is similar to that of non-destructive testing where it is looked for hidden cracks etc. in material via waves and rays. The non destructive testing profession is now about 100 years old and developed some procedures to check reliability of testing. Those principles like the performance demonstration where the successful detections are statistically evaluated against false calls rates and their implementation in an industrial standard (ASME section XI appendix VIII) are analysed. A first adoption to demining was accomplished in the prescription for blind trials in the CEN workshop agreement CEN BT 126
CWA07 for test and evaluation of metal detectors. A number of blind trials were accomplished within an ITEP project to learn about the necessary statistical layout of those trials to achieve true, reproducible and repeatable results to give guidance to selection and improvement of metal detectors. The special focus in these investigations was on the influence of the human factor due to the degree of experience of the operators and the infulence of uncooperative soil. The correlation of the results of the physical parameter measurement and the statistical results is analysed in a first attempt.
Die Integrität der Verstärkungsfasern in Komposit-Zahnstiften ist entscheidend für die Biegefestigkeit und die langfristige Haftung am Zement in den Wurzelkanälen. Es wurde vermutet, dass die Integrität von glasfaserverstärkten Zahnstiften durch das Beschleifen während der zahnmedizinischen Behandlung beeinträchtigt wird. Eine Beschädigung der Fasern führt zu einer erheblichen strukturellen Schwächung über den gesamten Stiftdurchmesser. Glasfragmente, die durch den Kontakt mit dem Zahnbohrer entstehen, können sich vom Stift lösen und die Haftfähigkeit erheblich verringern. Mit Hilfe hochauflösender Synchrotron-Röntgen-Refraktions-Radiographie (SXRR) konnte das Ausmaß der Schäden zuverlässig identifiziert und charakterisiert werden.
Dazu wurden die Glasfaserstifte sowohl im Herstellungszustand als auch nach der Bearbeitung mit einem Diamantbohrer untersucht. Die Datensätze wurden zur Visualisierung und Quantifizierung der morphologischen Charakteristika intakter und durch das Beschleifen beschädigter Regionen analysiert. Sie zeigen Schäden im bearbeiteten Bereich (z. B. Brüche, Splitter und Risse) sowie herstellungsbedingte Inhomogenitäten der Fasern mit einer signifikanten Zunahme der inneren Oberflächen in Probenregionen, die durch das Beschleifen beschädigt wurden.
Die Degradation von Wärmedämmschichten(thermal barrier coatings - TBCs) in Gasturbinen durch glasartige Calcium-Magnesium-Aluminiumsilikat (CMAS)Ablagerungen aus verschiedenen Quellen istseit vielen Jahren ein anhaltendes Problem. In dieser Studie wurde mit Hilfe derSynchrotron-Röntgen-Refraktions-Radiographie (SXRR), und vergleichend mit der Elektronenmikroskopie, das Eindringen von CMAS in die poröse Struktur von atmosphärisch plasmagespritzten (APS)TBCs sowie die Bildung und das Wachstum von Rissen unter thermisch zyklischer Belastung untersucht. Die Ergebnisse deuten darauf hin, dass die Infiltration sowie deren Kinetik im Brenner-Teststand wesentlich vom Benetzungsverhalten des CMAS beeinflusst werden. Trotz desoffensichtlichen Angriffs von CMAS auf die Korngrenzen hat die Wechselwirkung von Yttriumdioxid-stabilisiertem Zirkoniumdioxid (YSZ) mit intrudiertem CMAS keinen unmittelbaren Einfluss auf die Struktur und Dichte der innen Oberflächen(Risse, Poren). In einem späteren Stadium wird die Bildung von Rissen senkrecht zur äußeren Oberfläche in einer breiteren Zone der TBC-Schicht beobachtet.
Indoor air pollutants influence the health and comfort of building occupants and consequently the energy consumption of the building. The pollutants are emitted by various sources.
Among these sources, building products are of particular importance. To control the emission of pollutants from building materials, a few different voluntary labelling Systems have been introduced in Europe. In Germany also mandatory “Principles for the health assessment of construction products used in interiors” have been applied for the technical approval of floor coverings since 2004. This procedure is based on the assessment scheine of the Committee for Health-related
Evaluation of Building Products (AgBBScheme). The sensory-limit settings for building-material label Blue Angel offer consumer to differ not only low-emission but also low-odour Building materials from another building materials.