Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (45)
- Beitrag zu einem Tagungsband (42)
- Forschungsbericht (8)
- Beitrag zu einem Sammelband (6)
- Vortrag (1)
- Sonstiges (1)
- Posterpräsentation (1)
Sprache
- Englisch (74)
- Deutsch (29)
- Mongolisch (1)
Schlagworte
- Geruch (14)
- Bauprodukte (12)
- Emissionen (10)
- VOC (7)
- Prozessanalytik (6)
- Raman spectroscopy (6)
- XPS (6)
- Process analytical technology (5)
- AgBB-Schema (4)
- Hydroformylation (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (12)
- 8.5 Röntgenbildgebung (9)
- 6 Materialchemie (4)
- 6.1 Oberflächen- und Dünnschichtanalyse (4)
- 1 Analytische Chemie; Referenzmaterialien (3)
- 4 Material und Umwelt (3)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (3)
- 1.2 Biophotonik (2)
- 4.3 Schadstofftransfer und Umwelttechnologien (2)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (2)
Eingeladener Vortrag
- nein (1)
The present work shows results on elemental distribution analyses in Cu(In,Ga)Se2 thin films for solar cells performed by use of wavelength-dispersive and energy-dispersive X-ray spectrometry (EDX) in a scanning electron microscope, EDX in a transmission electron microscope, X-ray photoelectron, angle-dependent soft X-ray emission, secondary ion-mass (SIMS), time-of-flight SIMS, sputtered neutral mass, glow-discharge optical emission and glow-discharge mass, Auger electron, and Rutherford backscattering spectrometry, by use of scanning Auger electron microscopy, Raman depth profiling, and Raman mapping, as well as by use of elastic recoil detection analysis, grazing-incidence X-ray and electron backscatter diffraction, and grazing-incidence X-ray fluorescence analysis. The Cu(In,Ga)Se2 thin films used for the present comparison were produced during the same identical deposition run and exhibit thicknesses of about 2 µm. The analysis techniques were compared with respect to their spatial and depth resolutions, measuring speeds, availabilities, and detection limits.
Sintering and foaming of barium and calcium silicate glass powder compacts have been studied for different powder milling. Sintering was measured by means of heating microscopy backed up by XRD, DTA, Vacuum Hot Extraction (VHE) and electron microscopy. Foaming intensity strongly increased with decreasing glass partiefe size. Although powder compacts were uniaxially pressed and sintered in ambient air, foaming was affected by the milling atmosphere and most intensive for milfing in C02. Conformingly, VHE studies revealed that foaming of fully sintered samples was mainly driven by C02, even for powders milled in technical air, Ar and N2. Prolonged storage of air milled barium silicate glass powders in ambient air before pressing and sintering caused further increase of foaming intensity. These findings indicate that carbonaceous species are preferentially trapped to or close beneath the powder surface during milling and later storage. The temperature range of C02 degassing from fully sintered barium and calcium silicate g/ass powder compacts fits the temperature ranges of decomposition of BaC03 and CaC03 mix-milled with the respective barium and calcium silicate glass powders.
A variety of methods used to prepare nano-objects for surface analysis are described along with information about when they might be best applied. Intrinsic properties of NPs which complicate their characterization and need to be considered when planning for surface or other analyses of NPs are identified, including challenges associated with reproducible synthesis and functionalization of the particles as well as their dynamic nature. The relevant information about the sample preparation processes, along with analysis details and data that need to be added to the collection of material provenance information is identified. Examples of protocols that have been successfully used for preparation of nano-objects for surface analysis are included in an annex.
Micro-computed tomography (µCT) provides quantitative three-dimensional information of bone around titanium implants similar to classical histology. The study, based on an animal model, using cuboid-shaped biofunctionalised Ti6Al4V implants with surrounding bone after 4 weeks, is performed using 3 µCT-systems with X-ray tubes, one synchrotron-radiation-based µCT-system (SRµCT), and classical histology. Although the spatial resolution of the µCTsystems is comparable, only the results of SRµCT agree with results of classical histology. The X-ray tube sources give rise to huge artefacts in the tomograms (interface scattering, beam hardening), which impaired the quantitative analysis of bone up to about 200 µm from the implant surface. Due to the non-destructive character of µCT the specimens can be subsequently examined by classical histology
without restriction. The quantitative comparison of bone formation uncovers the strong dependence of the detected amount of newly formed bone from the selected slice. This
implies the necessity of 3D analysis. SRµCT and classical histology prove that surface modifications of the titanium implant significantly influence the bone formation. Using SRµCT, the preparation artefacts due to cutting and polishing are excluded.
Since the beginnings of the European American Workshops (EAW) in 1997, the aim was to gather the experts in NDE reliability and discuss burning topics with the aim of identifying crucial problems and suggesting ways to move forward. This was usually achieved during the so-called break-out sessions, in which predetermined topics were discussed. During the 5th EAW, held in Berlin in 2013, this approach was replaced by an Open Space Technology (OST) approach. The benefit of this approach is seen in the freedom of topic choices, i. e., the topics are not predetermined but rather arise at that moment in that space and by the participants choice. The following topics arose: new reliability methods (Bayesian, MAPOD,
), structural health monitoring, definition of requirements of NDE by customer versus provider, what value of POD is good enough?, human factors, manual versus automated inspection, and basic concepts of reliability of NDE. The participants were encouraged to walk from one session to another and openly express their opinions. These were in the end summarized by a chosen group of moderators and presented in this paper.
This paper gives an introduction to the field of human factors with the focus on their influence on the reliability of NDT in the nuclear energy production (in-service inspections) and final storage of highly radioactive nuclear waste. A set of methodological tools has been developed in the scope of three projects, namely: 1) a theoretical model describing potential human factors influencing manual ultrasonic inspection performance during inservice inspections in nuclear power plants; 2) a method for identifying potential human errors during acquisition and evaluation of data gathered with mechanized ultrasonic, radiographic and eddy-current systems, as well as visual testing with a remote camera (Failure Modes and Effects Analysis, FMEA); and 3) use of eye tracking methodology to optimize existing procedures and practices. The experimental results have shown that time pressure, mental workload and experience influence the quality of the inspection performance. Noticeable were influences from the organization of the working schedule, communication, procedures, supervision and demonstration task. Implementing human redundancy in critical tasks, such as defect identification, as well as using an automated aid (software) to help operators in decision making about the existence and size of defects, could lead to other kinds of problems, namely social loafing (excerpting less effort when working on tasks collectively as compared to working alone) and automation bias (uncritical reliance on the proper function of an automated system without recognizing its limitations and the possibilities of automation failure) that might affect the reliability of NDT in an undesired manner.
Die übergeordnete Zielsetzung unserer Untersuchung bestand darin,
am Beispiel von Prüfungen mit Ultraschall eine belastbare Aussage zum Einfluss der Arbeitsbedingungen des Prüfers auf die Qualität der Ergebnisse von zerstörungsfreien Prüfungen zu ermitteln und Möglichkeiten zur Minimierung ungünstiger Einflussfaktoren aufzuzeigen.
Der Schwerpunkt der Untersuchung wurde auf die manuelle Ultraschallprüfung gelegt und der Faktor 'Zeitdruck' (in drei Stufen variiert) als die zu variierende physische Einflussgröße gewählt. Die Variation des Faktors Zeitdruck wurde gemäß dem Prozessmodell von der Erhebung psychologischer Faktoren, die das Individuum und die Organisation beschreiben, begleitet.
Die Ultraschallprüfungen erfolgten mit zehn Prüfern am Großbehälter und an Vergleichskörpern mit eingebrachten Testfehlern (Nuten, Risse). Die ausgewählten Fehler waren typisch für Prüfaufgaben, die bei wiederkehrenden Ultraschallprüfungen in Kernkraftwerken von den Prüfern zu lösen sind. Die Prüfaufgabe bestand darin, die in den vorgegebenen Prüfabschnitten vorhandenen Reflektoren aufzufinden und deren Amplituden, Ortskoordinaten und Längenerstreckungen zu ermitteln. Als Bewertungsmaßstab für die Qualität der Prüfaussage und für den Einfluss des menschlichen Faktors diente die Präzision der gemessenen Werte. Die Ergebnisse zeigen einen hohen Einfluss des menschlichen Faktors auf das Prüfergebnis und eine Einwirkung des Zeitdrucks besonders auf die Präzision der Messwerte. Hierbei war die Wirkung des individuell wahrgenommenen Zeitdrucks zusammen mit der psychischen Arbeitsbeanspruchung signifikant. Es wurde unter anderem herausgearbeitet, dass durch eine gute Vorbereitung auf die Prüfung, z.B. durch die sorgfältige Einweisung und ein vorgeschaltetes Fertigkeitstraining an Vergleichskörpern, die Zuverlässigkeit der Prüfergebnisse verbessert werden kann.
Insgesamt hatte der Faktor 'Organisation' neben der 'Erfahrung' einen hohen Einfluss auf das Leistungsvermögen der Prüfer.
Die Projektergebnisse wurden im Abschlussbericht des Forschungsvorhabens SR2514 dargestellt, es wurden drei Empfehlungen zur Vorbereitung und Einweisung der Prüfer, zur Stärkung der Verantwortung der Prüfaufsicht und zum 4-Augen-Prinzip formuliert. Die Empfehlungen wurden in der KTA- Regel 3201.4 'Komponenten des Primärkreises von Leichtwasserreaktoren; Teil 4: Wiederkehrende Prüfungen und Betriebsüberwachung (RÄE Fassung 2010-11)', umgesetzt.
The sintering of bioactive glasses allows for the preparation of complex structures, such as three‐dimensional porous scaffolds. Such 3D constructs are particularly interesting for clinical applications of bioactive glasses in bone regeneration, as the scaffolds can act as a guide for in‐growing bone cells, allowing for good Integration with existing and newly formed tissue while the scaffold slowly degrades. Owing to the pronounced tendency of many bioactive glasses to crystallize upon heat treatment, 3D scaffolds have not been much exploited commercially. Here, we investigate the influence of crystallization on the sintering behavior of several bioactive glasses. In a series of mixed‐alkali glasses an increased CaO/alkali metal oxide Ratio improved sintering compared to Bioglass 45S5, where dense sintering was inhibited.
Addition of small amounts of calcium fluoride helped to keep melting and sintering temperatures low. Unlike glass 13‐93, these new glasses crystallized during sintering but this did not prevent densification. Variation in bioactive glass particle size allowed for fine‐tuning the microporosity resulting from the sintering process.