Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (36)
- Vortrag (31)
- Beitrag zu einem Tagungsband (26)
- Posterpräsentation (10)
- Sonstiges (4)
- Beitrag zu einem Sammelband (1)
- Forschungsbericht (1)
- Forschungsdatensatz (1)
Schlagworte
- Material moisture (19)
- Embedded sensors (15)
- Non-destructive testing (13)
- Building materials (12)
- Structural health monitoring (12)
- Concrete (11)
- Air-coupled ultrasound (10)
- RFID sensors (9)
- Moisture (8)
- RFID based sensors (8)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (76)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (70)
- 8.0 Abteilungsleitung und andere (8)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (7)
- 7 Bauwerkssicherheit (6)
- 7.2 Ingenieurbau (3)
- 7.4 Baustofftechnologie (3)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.2 Biophotonik (1)
- 8.6 Faseroptische Sensorik (1)
Eingeladener Vortrag
- nein (31)
-Über 80 Mio. Schwellen im deutschen Schienennetz verbaut
-Lebensdauer einer Schwelle beträgt ca. 20 bis 50 Jahre
-Über 2 Mio. Schwellen werden jährlich ausgetauscht, obwohl die Mehrzahl noch intakt ist
-Zustandsbewertung mittels ZfP kann Ausschuss verringern
-Schadhafte Schwellen könnten mittels ZfP frühzeitig im Gleis erkannt werden, um Gefahren und Unfälle abzuwenden
Das Neutronensondenverfahren wird bereits seit vielen Jahren erfolgreich zur Eingrenzung und Quantifizierung auftretender Feuchteschäden an Fußböden eingesetzt. Hierzu bedarf es jedoch einer Vielzahl zerstörender Sondierungsbohrungen, welche die gewonnenen Messdaten kalibrieren und eine Tiefenzuordnung des Flüssigwassers zulassen. Dadurch entsteht ein zeitlicher und finanzieller Aufwand, der durch den parallelen Einsatz des elektromagnetischen Radarverfahrens vermieden werden könnte. Mit seiner hohen Sensitivität für Wasser bietet diese Messmethode die Möglichkeit der vertikalen Lokalisierung von Feuchte, was zu einer automatisierten Klassifizierung typischer Schadensfälle beitragen soll.
In einem laufenden Forschungsvorhaben werden in systematischen Laborstudien gängige Schadensfälle an häufig anzutreffenden Fußbodenaufbauten simuliert und deren Einfluss auf die genannten Verfahren untersucht. Hierbei kommen Zement- und Anhydritestriche, sowie unterschiedliche Dämmmaterialen mit variierenden Schichtdicken zum Einsatz. Wesentlicher Bestandteil der Auswertung ist die Extraktion signifikanter Signalmerkmale des Radarverfahrens, welche Rückschlüsse auf den Schadensfall und ggf. die Wassermenge zulassen. Weiterführend sollen die Kombinationsmöglichkeiten der verschiedenen Signalmerkmale und der Neutronensondendaten durch Methoden der multivariaten Datenauswertung und des maschinellen Lernens geprüft werden. Die Unabhängigkeit gegenüber wechselnden Schichtdicken und Materialien steht hierbei besonders im Fokus und soll anhand der erzielten Ergebnisse evaluiert werden.
Die Ermittlung der Belegreife von Fußbodenestrichen ist im Bauwesen von hoher Bedeutung,
da es bei dem Verlegen von Parkett oder anderen Bodenbelägen auf Estrichen zu erheblichen
feuchtigkeitsbedingten Schäden kommen kann, wenn diese noch nicht hinreichend
getrocknet sind. Für die Messung des Feuchtegehalts wird üblicherweise auf zerstörende
Methoden wie das Darr- und CM-Verfahren zurückgegriffen, die Probennahmen erfordern
und nur punktuelle Informationen liefern.
Ziel dieser Forschungsstudie ist die Untersuchung der Eignung und Anwendbarkeit des
Georadars und der Kernspinresonanz (NMR) zur zerstörungsfreien und flächendeckenden
Feuchtemessung von Estrichen. Dazu wurden Messungen mit beiden Verfahren an einer
Gruppe zementgebundener (CT) und einer Gruppe anhydritgebundener (CA) Estriche
während ihres Austrocknungsprozesses bei einem Konstant-Klima durchgeführt. Bei dem
Radarverfahren werden Amplitude und Laufzeit elektromagnetischer Reflexionen, die durch den Wassergehalt beeinflusst werden, gemessen. Die Radarmessungen erfolgten auf jeder
Probe entlang von zwei senkrechten Profilen mit einer 2GHz-Antenne. Die Kernspinresonanz
steht aufgrund ihrer Abhängigkeit zur magnetischen Kernresonanz der 1H-Wasserstoffatomen
in Relation mit dem Wassergehalt in dem Messvolumen der zu untersuchenden
Probe. Die Untersuchungen erfolgten mit dem NMR MOUSE System in Aufsatztechnik.
Dabei liegt die Eindringtiefe bei 24,8 mm.
Bei den Untersuchungen lässt sich für CT-Estriche ein starker vertikaler Feuchtegradient
feststellen. Die CA-Estriche weisen hingegen nur einen schwachen Feuchtegradienten bis
nahezu konstante Amplituden über die gesamte Tiefe auf. Nach Erreichen einer Amplitude
von ca. 5-8 lässt sich keine weitere Amplitudenveränderung registrieren bzw. sind ab diesen
Zeitpunkt die Änderungen im Wassergehalt zu gering, um von der NMR aufgelöst zu werden.
In den Ergebnissen des Radarverfahrens lässt sich ebenfalls ein von dem Feuchtegehalt
abhängiges Verhalten der Messparameter beobachten. Mit zunehmender Trocknung kann
man eine Abnahme der Laufzeit zwischen direkter und an der Rückwand reflektierter Welle
messen. Die Amplituden beider Wellen hingegen nehmen während des Austrocknungsprozesses
zu. Im Gegensatz zur NMR erhält man keine tiefenbezogenen Informationen.
Es lassen sich aber Rückschlüsse auf den Feuchtegehalt im Gesamtvolumen ziehen.
Ultrasonic testing is a widely applied measurement method in materials research and medicine. Commonly, a transducer is coupled to the specimen directly or via a liquid coupling agent. While reducing acoustic transmission losses significantly, this procedure is time-consuming and cannot be used for sensitive specimens. Air-coupled ultrasound is a viable alternative in such cases, although suffering from very high acoustic transmission losses between transducer, air and specimen. The recently introduced fluidic transducer (FT) generates ultrasound by utilizing the instability of a supersonic air jet switched inside a fluidic amplifier. Since only air is used as the working medium and no vibrating surfaces are used for ultrasound generation, the transducer is able to efficiently generate large acoustic pressure amplitudes. The resulting acoustic field shares its directivity with the ejected high-velocity air jet. Thus, the acoustic energy needs to be redirected from the jet axis in order to make the fluidic transducer applicable to sensitive specimens. In this study, the effectivity of using sonic crystals (SCs) for this redirection is investigated using acoustic and flow measurements. SCs are air-permeable while being reflective to large acoustic frequency bands. It was shown that both a defect waveguide and a mirroring strategy successfully redirected the acoustic field from the air jet. Furthermore, the interaction of flow and SC showed strong acoustic quenching if the SC was placed too close to the FT outlet. Blockage of the jet entrainment due to the SC may result in slightly higher off-axis flow velocities locally, which should be considered in sensitive applications.
Ultraschallmessverfahren werden seit Langem erfolgreich für Prüfaufgaben im Bauwesen eingesetzt. Die dauerhafte Überwachung und frühzeitige Erkennung von Schäden an komplexen Neubauten und alternder Infrastruktur kann mittels Ultraschall-Transmissionsmessungen und speziellen Auswertemethoden, wie z. B. Korrelationverfahren und Codawelleninterferometrie, realisiert werden. Für die Dauerüberwachung wurde ein kompaktes System entwickelt, das Ultraschall-Messdaten erfassen und ins Internet auf einen FTP-Server übertragen kann. Es können hierbei alle angeschlossenen Prüfköpfe für jede Messung wahlweise als Sender oder Empfänger geschaltet werden. Es wurden Vorverstärker entwickelt, bei denen die Versorgung mit Strom über die Messleitung erfolgt. Dadurch können die Verstärker nahe am Prüfkopf positioniert werden. Durch Änderungen in den Ultraschall-Signalen können Schädigungen des Bauteils, wie z.B. Risse, in Echtzeit erkannt werden.
Completely embedded sensor systems for long-term
operation offer innovative possibilities for structural health
monitoring of concrete structures. Measuring of relevant
parameters, e.g., temperature, humidity, or indication of
corrosion can be performed with low energy sensors. This allows
to implement passive RFID sensor systems without cable
connection and battery, which are power supplied exclusively by
the electromagnetic field from the external reader device. To
evaluate characteristics and conditions of this concept, a
systematical investigation of the transmission characteristics with
variation of relevant parameters, as communication frequency,
installation depth, type of concrete, moisture content, etc. is
currently carried out in an interdisciplinary research project at
BAM. First results are presented in this paper.
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
In civil engineering, many structures are made of reinforced concrete. Most Degradation processes relevant to this material, e.g., corrosion, are related to an increased level of material moisture.
Therefore, moisture monitoring in reinforced concrete is regarded as a crucial method for structural health monitoring. In this study, passive radio frequency identification (RFID)-based sensors are embedded into the concrete. They are well suited for long-term operation over decades and are well protected against harsh environmental conditions. The energy supply and the data transfer of the humidity sensors are provided by RFID. The sensor casing materials are optimised to withstand the high alkaline environment in concrete, having pH values of more than 12. Membrane materials are also investigated to identify materials capable of enabling water vapour transport from the porous cement matrix to the embedded humidity sensor. By measuring the corresponding relative humidity with embedded passive RFID-based sensors, the cement hydration is monitored for 170 days.
Moreover, long-term moisture monitoring is performed for more than 1000 days. The Experiments show that embedded passive RFID-based sensors are highly suitable for long-term structural health monitoring in civil engineering.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
The duraBASt area at the highway intersection “Köln-Ost” is a large test field for road testing.
It includes the duraBASt test bridge which is approximately 66 m long and 14.25 m broad. This bridge is part of the “road in the 21st Century” project and is equipped with several sensors for structural health monitoring. This feasibility study is carried out to investigate the prerequisites necessary for the constraction of intelligent bridges in the foture. Embedded sensors are able to measure quantities such as temperature, strain, moisture, corrosion, etc. In the presented work, the focus is set on passive RFID-based sensors. The communication and energy supply are realised by a mobile transmitter through the concrete cover. Hence, no cables or batteries are required. The sensors are designed to withstand the alkaline environment in concrete. Thus, moisture and corrosion values are measurable for several decades.
Das vorliegende Arbeitspapier stellt den Stand des Wissens und der Forschung zum Einsatz von Sensorik in Straßenbefestigungen zur Erfassung von Eingangsgrößen und Merkmalen für die Substanzbewertung zusammenfassend dar. Unter Sensorik versteht dieses Arbeitspapier ganz allgemein technische Einrichtungen, mit denen man die Werte von physikalischen Größen erfassen und zur Interpretation darstellen kann.
Structural Health Monitoring (SHM) is an important part of buildings surveillance and maintenance to detect material failure as early as possible and to contribute in protection of structures and their users.
The implementation of Radio Frequency Identification (RFID) sensor systems without cable connection and battery into building components offers innovative possibilities to enable long-term in-situ SHM of addressed structures, bridges. The objectives of the presented study are complete embedding of RFID sensors systems in concrete, full passive communication with the systems, at best for the whole life span of structures. One challenge for this task is the highly alkaline environment in concrete, which requires non-degrading and robust encapsulation. Further Requirements are passive communication and energy supply, appropriate antenna design, placement and fixation in concrete, and the selection and implementation of sensors and connections. The concept is to develop and optimize a simple and robust system, which meets the requirements, as well as comprehensive validation in concrete specimen and real world applications. Two different systems were developed (HF and UHF RFID, respectively).
First tasks were the implementation of analog sensors using the superposition principle for the signal adaption. Investigation of suitable materials for robust encapsulation and sensor protection against basic environments.
Four materials were investigated in pH13 solution for 14 days - 3D-Printer-Polymer was completely resolved - PVC has no noticeable decrease in weight - (VitaPro) glass filter for the sensor protector, has weight loss 2.7% - The epoxy resin has increased by 1.8% due to moisture expansion Different concrete samples were prepared for the validation of the systems. RFID sensors were embedded in different integration depths. Investigate the energy- and data transfer through concrete, also with varying moisture content. Additionally, signal strength data was used to optimize and validate the antenna characteristics in concrete. Next steps are to guarantee a sufficient energy supply for UHF RFID systems embedded in different concrete mixtures and further embedding the HF and UHF RFID systems in real bridges and buildings to validate the long term monitoring.
Structural Health Monitoring (SHM) is an important part of buildings surveillance and maintenance to detect material failure as early as possible and to contribute in protection of structures and their users.
The implementation of Radio Frequency Identification (RFID) sensor systems without cable connection and battery into building components offers innovative possibilities to enable long-term in-situ SHM of addressed structures, bridges. The objectives of the presented study are complete embedding of RFID sensors systems in concrete, full passive communication with the systems, at best for the whole life span of structures. One challenge for this task is the highly alkaline environment in concrete, which requires non-degrading and robust encapsulation. Further Requirements are passive communication and energy supply, appropriate antenna design, placement and fixation in concrete, and the selection and implementation of sensors and connections. The concept is to develop and optimize a simple and robust system, which meets the requirements, as well as comprehensive validation in concrete specimen and real world applications. Two different systems were developed (HF and UHF RFID, respectively).
First tasks were the implementation of analog sensors using the superposition principle for the signal adaption. Investigation of suitable materials for robust encapsulation and sensor protection against basic environments.
Four materials were investigated in pH 13 solution for 14 days
- 3D-Printer-Polymer was completely resolved
- PVC has no noticeable decrease in weight
- (VitaPro) glass filter for the sensor protector, has weight loss 2.7 %
- The epoxy resin has increased by 1.8 % due to moisture expansion
Different concrete samples were prepared for the validation of the systems.
RFID sensors were embedded in different integration depths. Investigate the energy- and data transfer through concrete, also with varying moisture content. Additionally, signal strength data was used to optimize and validate the antenna characteristics in concrete. Next steps are to guarantee a sufficient energy supply for UHF RFID systems embedded in different concrete mixtures and further embedding the HF and UHF RFID systems in real bridges and buildings to validate the long term monitoring.
Long-term completely embedded sensor systems offer innovative possibilities for structural health Monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors.
This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external Reader device. To evaluate characteristics and conditions of this concept, a systematical Investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper.
Structural Health Monitoring (SHM) is an important topic for Industry 4.0. More and more systems are embedded in different materials and are connected to each other. To embed sensors for a long time in concrete, an exact preparation is required. In this paper, we identify Radio-Frequency Identification (RFID) as promising technology for monitoring of concrete structures. This paper present the concept for long term monitoring, defines the requirements and shows first development steps, for example, the system design, the possibilities of sensor connection, and an encapsulation for embedding in concrete.
One of the more difficult tasks for structural health monitoring is the continuous evaluation of the stability and load capacity of the building materials. This knowledge can be won, e.g., by taking material samples at the examining place with the drawback of partly destroying the structure. To avoid this, modern sensor and communication technologies offer promising methods for non-destructive testing. To address the tasks for monitoring of concrete structures, in the presented study, different sensors were combined with RFID transponders and embedded in concrete components.
Long-term completely embedded sensor systems offer innovative possibilities for structural health monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors. This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external reader device. To evaluate characteristics and conditions of this concept, a systematical investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper.
This paper is a further research on the topic of the complete embedding of radio frequency identification (RFID) sensors in concrete. The focus is on the antenna of the transponder. Earlier investigations of different RFID technologies, embedded in concrete, showed a difference in energy transmission. The transmission through concrete at ultra high frequency (UHF), in spite of the large signal range, does not match the targeted application specific task. Therefore, the antenna characteristics have been examined more closely. The antenna is an important component for the application of RFID. Through the antenna, energy and data transfer takes place, so it is important to design an optimal antenna to accomplish a maximum embedding depths in concrete. To identify the optimal antenna geometry, different UHF antenna types were selected and investigated. An experimental comparison was performed to gain more information about the damping behavior and antenna characteristics in concrete.
Damages in infrastructure due to moisture amount to billions of Euros every year. For a more predictive structural health monitoring in civil engineering, the detection and monitoring of hazardous moisture in steel reinforced concrete constructions is of high interest. The sensors have to be wireless, elsewise they weaken the concrete cover of the rebars. The lifetime of such constructions is normally decades, thus the sensors have to be battery-free and fully passive. Considering these requirements, passive RFID-based sensors are developed. Communication and energy supply are realized wireless via the electromagnetic field of a RFID transmitter. The passive RFID based sensors are embedded into the concrete to enable the monitoring of moisture transport in porous materials. Results of the hydration process are shown.
Ultrasonic methods are used in concrete investigations since decades. While being limited to transmission testing in the laboratory for a while, in-situ echo measurements for structural investigations and condition assessment have made their way into practical application in the past 20 years. However, several challenges remain. On one side, there are technical issues as limitations in depth of penetration, resolution and imaging capabilities. On the other side there are still gaps in validation, standardization and certification, which are limiting the applicability in condition/load capacity assessment.
This review reports a couple of developments which will help to overcome these issues. This includes technical developments as new devices which are easier to handle on site or giving a much deeper penetration depth (e.g. the LAUS device at BAM) as well as improvements in imaging by hardware update (e. g. air coupled ultrasound or coded signals) or new software (e. g. RTM imaging). To foster the application in real world projects we are as well working on standardization by developing new reference specimen with international partners which will ensure world-wide comparability of ultrasonic and other methods and quality assurance codes. Further, non-destructive methods are being used to update probabilistic models used for the reassessment of existing structures to support the structural engineer’s decisions.
When applying Ground Penetrating Radar (GPR) to assess the moisture content of building materials, different medium properties, dimensions, interfaces and other unknown influences may require specific strategies to achieve useful results. Hence, we present an overview of the various approaches to carry out moisture measurements with GPR in civil engineering (CE). We especially focus on the applied Signal features such as time, amplitude and frequency features and discuss their limitations. Since the majority of publications rely on one single feature when applying moisture measurements, we also hope to encourage the consideration of approaches that combine different signal features for further developments.
The effective gas diffusion coefficient describes the process of gas diffusion in porous materials. Several materials have a significant number of micropores in the lower nanometre range leading to a reduction of gas diffusion (Knudsen effect). In the case of partial pore saturation during adsorption, the available pore space is further reduced, as is the gas diffusion. In this study, the influence of partially saturated pores on the Knudsen effect and on the gas diffusion is quantified. Three different pore geometries are investigated (slit, cylindrical and spherical pores) and three different types of pore size distribution, including a broad equal distribution, three narrow normal distributions and two measured distributions of concrete.
Besides the intensive computation of the exact pore saturation, a simplified model with low computational requirements is suggested. This study shows that the influence of the water layer thickness on the effective diffusion becomes significant for pore radii below 50 nm and the assumed pore geometry is important. At the end, the overall effect is quantified for an amorphous material with most pore
radii below 30 nm. At a moisture level of 50% relative humidity, the effective diffusion is reduced by 35% due to partial saturation.
Zur Versiegelung von Endlagern für radioaktive oder chemische Abfälle in ehemaligen Salzbergwerken werden Verschlussbauwerke aus Salzbeton auf ihre Eignung geprüft. Seit einigen Jahren werden durch die Bundesgesellschaft Endlagerung (BGE) und der Bundesanstalt für Materialforschung und -prüfung (BAM) an Versuchsbauwerken Erfahrungen mit der Ultraschalltechnik zur Qualitätssicherung unter Tage gesammelt. Hierbei kommen sowohl kommerzielle und experimentelle Geräte zur Echoprüfung als auch eigens entwickelte Bohrlochsonden zum Einsatz. Alle Geräte basieren auf niederfrequenten s-Wellen-Punktkontaktprüfköpfen (25 kHz– 50 kHz), die in unterschiedlichen Arrays kombiniert werden. In mehreren Versuchsreihen gelang es, unverfüllte und teilverfüllte Risse über mehrere Meter zu verfolgen und in ihrer Lage abzubilden. Technische Einbauten konnten bis in ca. 8 m Tiefe im Bauwerk detektiert werden. Mit Hilfe aus der Geophysik adaptierte Abbildungsverfahren gelang es, einige bisher nicht detektierbare Features sichtbar zu machen.
Die Ergebnisse dienen sowohl der Analyse des Versuchsbauwerks als auch der Entwicklung eines Qualitätssicherungssystems für zukünftige reale Verschlussbauwerke.
Structural Health Monitoring (SHM) has become very important in today's rapidly developing time. High buildings, large bridges and complex technical structures need to be monitored continuously and this over long periods.
Visual monitoring cannot evaluate the internal condition of building structures. Thus, material embedded sensors are needed. Cable connection of these sensors pose the disadvantage of weak spots and water intrusion. For concrete embedded sensors the use of batteries is not convenient, because of limited lifetime, difficult charging, and generation of electrical waste.. Hence, monitoring should be implemented preferentially with firmly embedded passive RFID sensor modules. However, since the concrete structure forms an electromagnetically reflective and absorbing barrier, only limited energy can be transmitted to the module. This project requires a highly energy-saving system, which can record different sensor parameters at critical points.
Ultrasonic measurement technology has become indispensable in NDT-CE. Air-coupled ultrasonic (ACU) measurement techniques promise to reduce measurement time. However, the signal quality suffers from large specific impedance mismatch at the transducer-air and air-specimen interface. Additionally, large pressure amplitudes are necessary for the penetration depth required in NDT-CE applications. To address the specific requirements of ultrasonic testing in NDT-CE, a robust ACU transducer was developed, that generates ultrasound by quickly switching a pressurized air flow. The simple design of the fluidic transducer makes the device maintenance free and resilient against harsh environmental conditions. Since the signal is generated by aeroacoustics, there is no specific impedance mismatch between the transducer and the surrounding air. The ultrasonic signal exhibits frequencies in the 30-60 kHz range and is therefore well suited to penetrate heterogenous materials such as concrete. This contribution gives an introduction in the working principle and signal characteristics of the fluidic transducer. Its applicability to measurements in concrete is verified. A detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
Ultrasonic measurement technology has become indispensable in NDT-CE. Air-coupled ultrasonic (ACU) measurement techniques promise to reduce measurement time. However, the signal quality suffers from large specific impedance mismatch at the transducer-air and air-specimen interface. Additionally, large pressure amplitudes are necessary for the penetration depth required in NDT-CE applications.
To address the specific requirements of ultrasonic testing in NDT-CE, a robust ACU transducer was developed, that generates ultrasound by quickly switching a pressurized air flow. The simple design of the fluidic transducer makes the device maintenance free and resilient against harsh environmental conditions. Since the signal is generated by aeroacoustics, there is no specific impedance mismatch between the transducer and the surrounding air. The ultrasonic signal exhibits frequencies in the 30-60 kHz range and is therefore well suited to penetrate heterogenous materials such as concrete. This contribution gives an introduction in the working principle and signal characteristics of the fluidic transducer. A detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
In this ongoing research project, we study the influence of moisture damage on Ground Penetrating Radar (GPR) in different floor constructions. For this purpose, a measurement setup with interchangeable layers is developed to vary the screed material (cement or anhydrite) and insulation material (glass wool, perlite, expanded and extruded polystyrene), as well as the respective layer thickness. The evaluation of the 2 GHz common-offset radar measurements is focused on the extraction of distinctive signal features that can be used to classify the underlying case of damage without any further information about the hidden materials or layer thicknesses. In the collected dataset, we analyze the horizontal distribution of A-scan features in corresponding B-scans to detect water in the insulation layer. Furthermore, possible combinations of these features are investigated with the use of multivariate data analysis and machine learning (logistic regression) in order to evaluate the mutual dependencies. In this study, the combination of an amplitude- and frequency-based feature achieved an accuracy of 93.2 % and performed best to detect a damage in floor insulations.
Research and Development in Non-Destructive Testing in Civil Engineering at BAM has de-veloped over more than two decades. Highlights of present research are ultrasound phase array probes, ground penetrating radar applications for the assessment of existing structures and Laser Induced Breakdown Spec-troscopy (LIBS) to determine which chemical elements on the surface of a specimen are. RFID sensor devel-opments for wireless moisture monitoring and data fusion for the combined analysis of sensor data are fast developing areas. In addition, a selection of application cases is briefly described.
Um den Feuchtegehalt von Fußbodenestrich vor der Verlegung von Holz- oder anderen
Bodenbelägen zu bestimmen, werden zerstörende Prüfverfahren wie die Calcium-Carbid
Methode (CM) oder das thermogravimetrische Darr-Verfahren eingesetzt. Diese liefern
jedoch einmalig nur punktuelle Informationen und sind je nach Estrichtyp auch störanfällig.
Zusammen mit Partnern aus Forschung und Industrie wurde an der BAM ein Ringversuch
durchgeführt, dessen Ziel es war, verschiedene nach Möglichkeit zerstörungsfreie oder –
arme Prüfverfahren hinsichtlich ihrer Genauigkeit und Sensitivität vor allem im Bereich der
Belegereife zu testen. Hier dargestellt sind die Ergebnisse aufgenommen an einer
Calciumsulphat-Estrich Probe vom Typ Knauf FE80 Largo mit drei Verfahren, die auch
Aussagen über die Feuchtegradienten in die Tiefe zulassen. Die Proben wurden bei
Konstant-Normklima mit T=23 °C und rH=50 % zur Trocknung gelagert.
Um den Feuchtegehalt von Fußbodenestrich vor der Verlegung von Holz- oder anderen Bodenbelägen zu bestimmen, werden zerstörende Prüfverfahren wie die Calcium-Carbid Methode (CM) oder das thermogravimetrische Darr-Verfahren eingesetzt. Diese liefern jedoch einmalig nur punktuelle Informationen und sind je nach Estrichtyp auch störanfällig. Zusammen mit Partnern aus Forschung und Industrie wurde an der BAM ein Ringversuch durchgeführt, dessen Ziel es war, verschiedene nach Möglichkeit zerstörungsfreie oder – arme Prüfverfahren hinsichtlich ihrer Genauigkeit und Sensitivität vor allem im Bereich der Belegereife zu testen. Hier dargestellt sind die Ergebnisse aufgenommen an einer Calciumsulphat-Estrich Probe vom Typ Knauf FE80 Largo mit drei Verfahren, die auch Aussagen über die Feuchtegradienten in die Tiefe zulassen. Die Proben wurden bei Konstant-Normklima mit T=23 °C und rH=50 % zur Trocknung gelagert.
Monitoring of the absolute water content in porous materials based on embedded humidity sensors
(2018)
Moisture transport monitoring may indicate the onset of deterioration in porous building materials Prior to damage occurring. Most moisture measurement systems provide only qualitative values, require extensive calibration, or are destructive. Thus, non-destructive and calibration-free monitoring Systems are required. Our approach of moisture monitoring is to embed sensors that measure the relative humidity.
In our experiment, screed samples are monitored during the Hydration and evaporation process. Every test sample is equipped with 10 embedded sensors which measure the relative humidity across the sample thickness. Based on Hillerborg’s approach, the relative humidity is converted into the corresponding pore saturation. In our study, the free water is computed without knowledge of the Sorption isotherm. The free water in the pore system is predicted and validated. The predicted weight decrease corresponds conclusively to gravimetrically measured weights. The embedded sensors yield the absolute liquid water content and enable an experimental, non-destructive monitoring of liquid water in porous materials.
Moisture testing and mapping
(2018)
Moisture testing and mapping
(2017)
Moisture testing and mapping
(2017)
Moisture testing and mapping
(2017)
Eight different screed types are tested including two different sample heights of 35 and 70 mm. The moisture of the four cement based and four sulphate based screeds are monitored during hydration and evaporation. All samples are stored in a climatic chamber at 23° C and 50 % relative humidity. Embedded sensors like temperature arrays, humidity sensor arrays, and multi-ring electrodes are embedded in the samples to yield a detailed moisture evolution with high depth resolution. Furthermore, nuclear magnetic resonance is used to quantify the water content at different depths. This multi-sensor approach allows a comprehensive monitoring of the moisture and its gradient in the different screed samples. This yields a deeper insight into the hydration, moisture convection, and diffusion processes.
Moisture testing and mapping
(2023)
To quantify the moisture in concrete, RFID based humidity sensors are embedded. Passive high frequency, ultra-high frequency RFID tags as well as active Bluetooth sensors are tested. After concreting, all sensors measure the corresponding relative humidity to monitor the concrete moisture. Two case studies are performed, embedding in an existing construction, i.e. the duraBASt test bridge, and embedding in cement based mortar in the laboratory. As basis for robust and long-life sensors in alkaline concrete, different casing materials are tested. Furthermore, signal strength measurements and their sensitivity to different moisture levels are performed.
To quantify the moisture in concrete, RFID based humidity sensors are embedded. Passive high frequency, ultra-high frequency RFID tags as well as active Bluetooth sensors are tested. After concreting, all sensors measure the corresponding relative humidity to monitor the concrete moisture. Two case studies are performed, embedding in an existing construction, i.e. the duraBASt test bridge, and embedding in cement based mortar in the laboratory. As basis for robust and long-life sensors in alkaline concrete, different casing materials are tested. Furthermore, signal strength measurements and their sensitivity to different moisture levels are performed.
Eight different screed types are tested including two different sample heights of 35 and 70 mm. The moisture of the four cement based and four sulphate based screeds are monitored during hydration and evaporation. All samples are stored in a climatic chamber at 23° C and 50 % relative humidity. Embedded sensors like temperature arrays, humidity sensor arrays, and multi-ring electrodes are embedded in the samples to yield a detailed moisture evolution with high depth resolution. Furthermore, nuclear magnetic resonance is used to quantify the water content at different depths. This multi-sensor approach allows a comprehensive monitoring of the moisture and its gradient in the different screed samples. This yields a deeper insight into the hydration, moisture convection, and diffusion processes.