Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (36)
- Vortrag (31)
- Beitrag zu einem Tagungsband (26)
- Posterpräsentation (10)
- Sonstiges (4)
- Beitrag zu einem Sammelband (1)
- Forschungsbericht (1)
- Forschungsdatensatz (1)
Schlagworte
- Material moisture (19)
- Embedded sensors (15)
- Non-destructive testing (13)
- Building materials (12)
- Structural health monitoring (12)
- Concrete (11)
- Air-coupled ultrasound (10)
- RFID sensors (9)
- Moisture (8)
- RFID based sensors (8)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (74)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (70)
- 8.0 Abteilungsleitung und andere (8)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (7)
- 7 Bauwerkssicherheit (6)
- 7.2 Ingenieurbau (3)
- 7.4 Baustofftechnologie (3)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.2 Biophotonik (1)
- 8.6 Faseroptische Sensorik (1)
Eingeladener Vortrag
- nein (31)
In this communication a novel concept for pH sensing is introduced which is specifically adapted to monitor carbonation induced corrosion in concrete structures. The method is based on a ratiometric measurement principle, exploiting the pH sensitive colour switching of thymol blue in the basic pH regime and the emissive properties of two different (Zn)CdSe/ZnS core shell quantum dots. The transition point of thymol blue in a Hydrogel D4 matrix was determined to be at around pH 11.6, which fits ideally to the intended application. Next to the fundamental spectroscopic characterization of the ratiometric response, a new design for a sensor head, suitable for the incorporation into concrete matrices is presented. Toward this, a manufacturing process was developed which includes the preparation of a double layer of polymers containing either thymol blue or a quantum dot mixture inside a porous ceramic tube. Results of a proof-of-priciple performance test of the sensor head in solutions of different pH and in cement specimens are presented, with encouraging results paving the way for future field tests in concrete.
Long-term completely embedded sensor systems offer innovative possibilities for structural health monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors. This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external reader device. To evaluate characteristics and conditions of this concept, a systematical investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper.
Completely embedded sensor systems for long-term
operation offer innovative possibilities for structural health
monitoring of concrete structures. Measuring of relevant
parameters, e.g., temperature, humidity, or indication of
corrosion can be performed with low energy sensors. This allows
to implement passive RFID sensor systems without cable
connection and battery, which are power supplied exclusively by
the electromagnetic field from the external reader device. To
evaluate characteristics and conditions of this concept, a
systematical investigation of the transmission characteristics with
variation of relevant parameters, as communication frequency,
installation depth, type of concrete, moisture content, etc. is
currently carried out in an interdisciplinary research project at
BAM. First results are presented in this paper.
Embedded wireless sensor systems for long-term SHM and corrosion detection in concrete components
(2017)
State-of-the-art communication standards like RFID and Bluetooth Low Energy enable the development of sensor systems which can be completely embedded into concrete components for long-term SHM and early damage detection. Objective of the project KonSens which is carried out at BAM is the development, implementation, and validation of sensors for measuring of Parameters relevant for corrosion, like moisture, pH value, and electrical conductivity, inside steel reinforced concrete components. The primarily addressed application is detection and evaluation of corrosion processes in concrete bridges.
In contrast to cable connected sensors, embedded wireless sensors avoid any pathways for intrusion of moisture and chemicals, e.g., chlorides which could trigger corrosion activity. To allow for long-term, ideally life-time operation, the once embedded sensor systems must work highly energy efficient. One option are passive RFID sensor systems, which work without battery. The energy is transmitted to the system through the electromagnetic field, even to operate sensors. A crucial parameter is the transmission depth in concrete. First experiments with RFID sensors working at frequencies of 13.56 MHz (HF) and 868 MHz (UHF) embedded in concrete specimen resulted positive for transmission depths of up to 13 cm, which is quite promising, considering that corrosion would appear first at the top level of rebars.
A second generation of passive RFID sensor systems has been implemented with improved antenna design. Current experiments using these systems focus on the Transmission characteristics in terms of transmission depths and the impact of concrete moisture. Low-energy humidity sensors are used and analysed regarding their capability for measuring the material moisture. Additionally, a relation between transmitted power to the embedded sensor and the moisture content of the concrete specimen caused by energy absorption can be presumed and is under systematic investigation.
Long-term completely embedded sensor systems offer innovative possibilities for structural health Monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors.
This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external Reader device. To evaluate characteristics and conditions of this concept, a systematical Investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper.
Development of an Accurate and Robust Air-Coupled Ultrasonic Time-of-Flight Measurement Technique
(2022)
Ultrasonic time-of-flight (ToF) measurements enable the non-destructive characterization of material parameters as well as the reconstruction of scatterers inside a specimen. The time-consuming and potentially damaging procedure of applying a liquid couplant between specimen and transducer can be avoided by using air-coupled ultrasound. However, to obtain accurate ToF results, the waveform and travel time of the acoustic signal through the air, which are influenced by the ambient conditions, need to be considered. The placement of microphones as signal receivers is restricted to locations where they do not affect the sound field. This study presents a novel method for in-air ranging and ToF determination that is non-invasive and robust to changing ambient conditions or waveform variations. The in-air travel time was determined by utilizing the azimuthal directivity of a laser Doppler vibrometer operated in refracto-vibrometry (RV) mode. The time of entry of the acoustic signal was determined using the autocorrelation of the RV signal. The same signal was further used as a reference for determining the ToF through the specimen in transmission mode via cross-correlation. The derived signal processing procedure was verified in experiments on a polyamide specimen. Here, a ranging accuracy of <0.1 mm and a transmission ToF accuracy of 0.3μs were achieved. Thus, the proposed method enables fast and accurate non-invasive ToF measurements that do not require knowledge about transducer characteristics or ambient conditions.
Air-coupled ultrasonic (ACU) testing has proven to be a valuable method for increasing the speed in non-destructive ultrasonic testing and the investigation of sensitive specimens. A major obstacle to implementing ACU methods is the significant signal power loss at the air–specimen and transducer–air interfaces. The loss between transducer and air can be eliminated by using recently developed fluidic transducers. These transducers use pressurized air and a natural flow instability to generate high sound power signals. Due to this self-excited flow instability, the individual pulses are dissimilar in length, amplitude, and phase. These amplitude and angle modulated pulses offer the great opportunity to further increase the signal-to-noise ratio with pulse compression methods.
In practice, multi-input multi-output (MIMO) setups reduce the time required to scan the specimen surface, but demand high pulse discriminability. By applying envelope removal techniques to the individual pulses, the pulse discriminability is increased allowing only the remaining phase information to be targeted for analysis. Finally, semi-synthetic experiments are presented to verify the applicability of the envelope removal method and highlight the suitability of the fluidic transducer for MIMO setups.
This data article presents characteristic acoustic and flow data of a fluidic ultrasonic transducer as well as acoustic data of a commercial piezoelectric ultrasonic transducer used in non-destructive testing for civil engineering. The flow data has been acquired using hot-wire anemometry and a Pitot tube. The three-dimensional acoustic data of both devices has been acquired using a calibrated microphone. The distribution of characteristic acoustic properties of both transducers are extracted and given in addition to the raw data. The data presented in the article will be a valuable source for reference and validation, both for developing fluidic and alternate ultrasound generation technologies. Furthermore, they will give additional insight into the acoustic-flow interaction phenomena of high speed switching devices. This article is accompanying the paper Experimental Analysis of the Acoustic Field of an Ultrasonic Pulse Induced by a Fluidic Switch (Bühling et al., 2021) published in The Journal of the Acoustical Society of America, where the data is interpreted in detail and the rationale for characteristic sound properties of the fluidic transducer are given.
AbstractAir‐coupled ultrasonic testing (ACU) is a pioneering technique in non‐destructive testing (NDT). While contact testing and fluid immersion testing are standard methods in many applications, the adoption of ACU is progressing slowly, especially in the low ultrasonic frequency range. A main reason for this development is the difficulty of generating high amplitude ultrasonic bursts with equipment that is robust enough to be applied outside a laboratory environment. This paper presents the fluidic ultrasonic transducer as a solution to this challenge. This novel aeroacoustic source uses the flow instability of a sonic jet in a bistable fluidic switch to generate ultrasonic bursts up to 60 kHz with a mean peak pressure of 320 Pa. The robust design allows operation in adverse environments, independent of the operating fluid. Non‐contact through‐transmission experiments are conducted on four materials and compared with the results of conventional transducers. For the first time, it is shown that the novel fluidic ultrasonic transducer provides a suitable acoustic signal for NDT tasks and has potential of furthering the implementation of ACU in industrial applications.This article is protected by copyright. All rights reserved
Ultrasonic measurement technology has become indispensable in NDT-CE. Air-coupled ultrasonic (ACU) measurement techniques promise to reduce measurement time. However, the signal quality suffers from large specific impedance mismatch at the transducer-air and air-specimen interface. Additionally, large pressure amplitudes are necessary for the penetration depth required in NDT-CE applications. To address the specific requirements of ultrasonic testing in NDT-CE, a robust ACU transducer was developed, that generates ultrasound by quickly switching a pressurized air flow. The simple design of the fluidic transducer makes the device maintenance free and resilient against harsh environmental conditions. Since the signal is generated by aeroacoustics, there is no specific impedance mismatch between the transducer and the surrounding air. The ultrasonic signal exhibits frequencies in the 30-60 kHz range and is therefore well suited to penetrate heterogenous materials such as concrete. This contribution gives an introduction in the working principle and signal characteristics of the fluidic transducer. Its applicability to measurements in concrete is verified. A detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
Ultrasonic testing is a widely applied measurement method in materials research and medicine. Commonly, a transducer is coupled to the specimen directly or via a liquid coupling agent. While reducing acoustic transmission losses significantly, this procedure is time-consuming and cannot be used for sensitive specimens. Air-coupled ultrasound is a viable alternative in such cases, although suffering from very high acoustic transmission losses between transducer, air and specimen. The recently introduced fluidic transducer (FT) generates ultrasound by utilizing the instability of a supersonic air jet switched inside a fluidic amplifier. Since only air is used as the working medium and no vibrating surfaces are used for ultrasound generation, the transducer is able to efficiently generate large acoustic pressure amplitudes. The resulting acoustic field shares its directivity with the ejected high-velocity air jet. Thus, the acoustic energy needs to be redirected from the jet axis in order to make the fluidic transducer applicable to sensitive specimens. In this study, the effectivity of using sonic crystals (SCs) for this redirection is investigated using acoustic and flow measurements. SCs are air-permeable while being reflective to large acoustic frequency bands. It was shown that both a defect waveguide and a mirroring strategy successfully redirected the acoustic field from the air jet. Furthermore, the interaction of flow and SC showed strong acoustic quenching if the SC was placed too close to the FT outlet. Blockage of the jet entrainment due to the SC may result in slightly higher off-axis flow velocities locally, which should be considered in sensitive applications.
While contact and immersion ultrasonic testing are established methods in non-destructive testing (NDT), generating high power air-coupled ultrasound remains a challenging task. Solutions often involve setups that are restricted to lab environments. When field measurements are required, such as in NDT for civil engineering, a handy, robust and safe transducer is needed. For this purpose, an ultrasonic transducer based on a fluidic switch has been developed. A sonic air flow inside the device is switched rapidly so that an ultrasonic signal is generated. Both theory and previous flow simulations suggest that the control flow pressure ramp has only little influence on the switching time of the device. This publication gives an overview over the operating principle of the fluidic ultrasonic transducer and investigates the influence of control tube length and pulsing repetition rate on the ultrasonic pressure amplitude. High repetition rates are found to reduce the signal amplitude, whereas long tubing has only little negative influence on the amplitude while improving signal quality.
Entwicklung eines luftgekoppelten Ultraschall-Echo-Prüfverfahrens mittels fluidischer Anregung
(2019)
In vielen technischen Bereichen werden Ultraschallverfahren zur zer-störungsfreien Werkstoffprüfung eingesetzt. Dabei wird ein Schallpuls von einem Prüfkopf in ein Prüfobjekt eingebracht. Der Puls kann unter anderem durch Membra-nen oder Piezoelemente erzeugt werden und wird in der Regel durch direkten Kontakt oder über ein Koppelmittel an das Objekt übertragen. Luftgekoppelter Ultraschall spielt in kommerziellen Anwendungen bisher eine untergeordnete Rolle, da die Dif-ferenz der akustischen Impedanzen von Luft und Festkörpern immense Verluste beim Übergang des Schallsignals hervorruft.
In diesem Beitrag soll ein neuartiges Anregungsprinzip vorgestellt werden, mit dem ein Großteil dieser Verluste vermieden wird. Anstelle eines Festkörpers soll mit Hilfe einer fluidischen Düse Druckluft zur Signalerzeugung eingesetzt werden. In die-ser Düse wird eine selbsterhaltende Strömungsinstabilität erzeugt, die einen Schall-puls von bis zu 100 kHz hervorruft, sodass der Impedanzverlust in die Umgebungsluft entfällt. Da die charakteristische Frequenz eines fluidisch generierten Pulses maßgeb-lich von der Bauform der Düse und dem anliegenden Druck abhängt, lässt sich mittels einer geeigneten Strömungsregelung ein breiter Frequenzbereich zur Abtastung nut-zen. Die so emittierten Pulse werden auf das Prüfobjekt gerichtet und die reflektierten Signale mit einem Laservibrometer an der Oberfläche des Objekts im Echo-Verfahren abgetastet. Von drei signalmindernden Materialübergängen bei gewöhnlichem luftge-koppeltem Ultraschall bleibt in dem hier vorgeschlagenen Messystem lediglich die Grenzfläche von Luft zu Prüfkörper, sodass eine höhere Signalausbeute als bisher er-wartet werden kann.
Experimental analysis of the acoustic field of an ultrasonic pulse induced by a fluidic switch
(2021)
Ultrasonic inspection is a common tool for non-destructive testing in civil engineering (NDT-CE). Currently, transducers are coupled directly to the specimen surface, which makes the inspection time-consuming. Air-coupled ultrasound (ACU) transducers are more time-efficient but need a high pressure amplitude as the impedance mismatch between the air and the concrete is high and large penetration depth is needed for the inspection. Current approaches aim at eliminating the impedance mismatch between the transducer and the air to gain amplitude; however, they hardly fulfill the NDT-CE requirements. In this study, an alternative approach for ultrasound generation is presented: the signal is generated by a fluidic switch that rapidly injects a mass flow into the ambience. The acoustic field, the flow field, and their interaction are investigated. It is shown that the signal has dominant frequencies in the range of 35–60 kHz, and the amplitude is comparable to that of a commercial ACU transducer.
The effect of high-amplitude harmonic surging on airfoil laminar separation bubbles, at small angles of attack, was investigated experimentally in a dedicated surging-flow wind tunnel. A generalized pressure coefficient was developed that accounts for local static pressure variations due to surging. This critical generalization facilitated direct comparisons between surging and quasisteady pressure coefficients, and thus unsteady effects could be distinguished from Reynolds number effects. A momentum-integral boundary layer analysis was implemented to determine movement of the bubble separation point, and movement of the transition point was extracted from experimental surface pressure coefficients. The most significant finding was that bubble bursting occurs, counterintuitively, during early imposition of the favorable temporal pressure gradient, because the favorable pressure gradient rapidly drives the bubble aft, rendering it unable to reattach. This surge-induced dynamic stall mechanism resulted in large lift and form-drag coefficient oscillations.
Furthermore, failure to implement the generalized pressure coefficient definition resulted in temporal form-drag coefficient errors of up to 400 counts.
Das vorliegende Arbeitspapier stellt den Stand des Wissens und der Forschung zum Einsatz von Sensorik in Straßenbefestigungen zur Erfassung von Eingangsgrößen und Merkmalen für die Substanzbewertung zusammenfassend dar. Unter Sensorik versteht dieses Arbeitspapier ganz allgemein technische Einrichtungen, mit denen man die Werte von physikalischen Größen erfassen und zur Interpretation darstellen kann.
This paper is a further research on the topic of the complete embedding of radio frequency identification (RFID) sensors in concrete. The focus is on the antenna of the transponder. Earlier investigations of different RFID technologies, embedded in concrete, showed a difference in energy transmission. The transmission through concrete at ultra high frequency (UHF), in spite of the large signal range, does not match the targeted application specific task. Therefore, the antenna characteristics have been examined more closely. The antenna is an important component for the application of RFID. Through the antenna, energy and data transfer takes place, so it is important to design an optimal antenna to accomplish a maximum embedding depths in concrete. To identify the optimal antenna geometry, different UHF antenna types were selected and investigated. An experimental comparison was performed to gain more information about the damping behavior and antenna characteristics in concrete.
Structural Health Monitoring (SHM) has become very important in today's rapidly developing time. High buildings, large bridges and complex technical structures need to be monitored continuously and this over long periods.
Visual monitoring cannot evaluate the internal condition of building structures. Thus, material embedded sensors are needed. Cable connection of these sensors pose the disadvantage of weak spots and water intrusion. For concrete embedded sensors the use of batteries is not convenient, because of limited lifetime, difficult charging, and generation of electrical waste.. Hence, monitoring should be implemented preferentially with firmly embedded passive RFID sensor modules. However, since the concrete structure forms an electromagnetically reflective and absorbing barrier, only limited energy can be transmitted to the module. This project requires a highly energy-saving system, which can record different sensor parameters at critical points.
One of the more difficult tasks for structural health monitoring is the continuous evaluation of the stability and load capacity of the building materials. This knowledge can be won, e.g., by taking material samples at the examining place with the drawback of partly destroying the structure. To avoid this, modern sensor and communication technologies offer promising methods for non-destructive testing. To address the tasks for monitoring of concrete structures, in the presented study, different sensors were combined with RFID transponders and embedded in concrete components.
Structural Health Monitoring (SHM) is an important part of buildings surveillance and maintenance to detect material failure as early as possible and to contribute in protection of structures and their users.
The implementation of Radio Frequency Identification (RFID) sensor systems without cable connection and battery into building components offers innovative possibilities to enable long-term in-situ SHM of addressed structures, bridges. The objectives of the presented study are complete embedding of RFID sensors systems in concrete, full passive communication with the systems, at best for the whole life span of structures. One challenge for this task is the highly alkaline environment in concrete, which requires non-degrading and robust encapsulation. Further Requirements are passive communication and energy supply, appropriate antenna design, placement and fixation in concrete, and the selection and implementation of sensors and connections. The concept is to develop and optimize a simple and robust system, which meets the requirements, as well as comprehensive validation in concrete specimen and real world applications. Two different systems were developed (HF and UHF RFID, respectively).
First tasks were the implementation of analog sensors using the superposition principle for the signal adaption. Investigation of suitable materials for robust encapsulation and sensor protection against basic environments.
Four materials were investigated in pH 13 solution for 14 days
- 3D-Printer-Polymer was completely resolved
- PVC has no noticeable decrease in weight
- (VitaPro) glass filter for the sensor protector, has weight loss 2.7 %
- The epoxy resin has increased by 1.8 % due to moisture expansion
Different concrete samples were prepared for the validation of the systems.
RFID sensors were embedded in different integration depths. Investigate the energy- and data transfer through concrete, also with varying moisture content. Additionally, signal strength data was used to optimize and validate the antenna characteristics in concrete. Next steps are to guarantee a sufficient energy supply for UHF RFID systems embedded in different concrete mixtures and further embedding the HF and UHF RFID systems in real bridges and buildings to validate the long term monitoring.
Structural Health Monitoring (SHM) is an important topic for Industry 4.0. More and more systems are embedded in different materials and are connected to each other. To embed sensors for a long time in concrete, an exact preparation is required. In this paper, we identify Radio-Frequency Identification (RFID) as promising technology for monitoring of concrete structures. This paper present the concept for long term monitoring, defines the requirements and shows first development steps, for example, the system design, the possibilities of sensor connection, and an encapsulation for embedding in concrete.
Structural Health Monitoring (SHM) is an important part of buildings surveillance and maintenance to detect material failure as early as possible and to contribute in protection of structures and their users.
The implementation of Radio Frequency Identification (RFID) sensor systems without cable connection and battery into building components offers innovative possibilities to enable long-term in-situ SHM of addressed structures, bridges. The objectives of the presented study are complete embedding of RFID sensors systems in concrete, full passive communication with the systems, at best for the whole life span of structures. One challenge for this task is the highly alkaline environment in concrete, which requires non-degrading and robust encapsulation. Further Requirements are passive communication and energy supply, appropriate antenna design, placement and fixation in concrete, and the selection and implementation of sensors and connections. The concept is to develop and optimize a simple and robust system, which meets the requirements, as well as comprehensive validation in concrete specimen and real world applications. Two different systems were developed (HF and UHF RFID, respectively).
First tasks were the implementation of analog sensors using the superposition principle for the signal adaption. Investigation of suitable materials for robust encapsulation and sensor protection against basic environments.
Four materials were investigated in pH13 solution for 14 days - 3D-Printer-Polymer was completely resolved - PVC has no noticeable decrease in weight - (VitaPro) glass filter for the sensor protector, has weight loss 2.7% - The epoxy resin has increased by 1.8% due to moisture expansion Different concrete samples were prepared for the validation of the systems. RFID sensors were embedded in different integration depths. Investigate the energy- and data transfer through concrete, also with varying moisture content. Additionally, signal strength data was used to optimize and validate the antenna characteristics in concrete. Next steps are to guarantee a sufficient energy supply for UHF RFID systems embedded in different concrete mixtures and further embedding the HF and UHF RFID systems in real bridges and buildings to validate the long term monitoring.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
When applying Ground Penetrating Radar (GPR) to assess the moisture content of building materials, different medium properties, dimensions, interfaces and other unknown influences may require specific strategies to achieve useful results. Hence, we present an overview of the various approaches to carry out moisture measurements with GPR in civil engineering (CE). We especially focus on the applied Signal features such as time, amplitude and frequency features and discuss their limitations. Since the majority of publications rely on one single feature when applying moisture measurements, we also hope to encourage the consideration of approaches that combine different signal features for further developments.
To date, the destructive extraction and analysis of drilling cores is the main possibility to obtain depth information about damaging water ingress in building floors. The time- and costintensive procedure constitutes an additional burden for building insurances that already list piped water damage as their largest item. With its high sensitivity for water, a ground-penetrating radar (GPR) could provide important support to approach this problem in a non-destructive way. In this research, we study the influence of moisture damage on GPR signals at different floor constructions. For this purpose, a modular specimen with interchangeable layers is developed to vary the screed and insulation material, as well as the respective layer thickness. The obtained data set is then used to investigate suitable signal features to classify three scenarios: dry, damaged insulation, and damaged screed. It was found that analyzing statistical distributions of A-scan features inside one B-scan allows for accurate classification on unknown floor constructions. Combining the features with multivariate data analysis and machine learning was the key to achieve satisfying results. The developed method provides a basis for upcoming validations on real damage cases.
Das Neutronensondenverfahren wird bereits seit vielen Jahren erfolgreich zur Eingrenzung und Quantifizierung auftretender Feuchteschäden an Fußböden eingesetzt. Hierzu bedarf es jedoch einer Vielzahl zerstörender Sondierungsbohrungen, welche die gewonnenen Messdaten kalibrieren und eine Tiefenzuordnung des Flüssigwassers zulassen. Dadurch entsteht ein zeitlicher und finanzieller Aufwand, der durch den parallelen Einsatz des elektromagnetischen Radarverfahrens vermieden werden könnte. Mit seiner hohen Sensitivität für Wasser bietet diese Messmethode die Möglichkeit der vertikalen Lokalisierung von Feuchte, was zu einer automatisierten Klassifizierung typischer Schadensfälle beitragen soll.
In einem laufenden Forschungsvorhaben werden in systematischen Laborstudien gängige Schadensfälle an häufig anzutreffenden Fußbodenaufbauten simuliert und deren Einfluss auf die genannten Verfahren untersucht. Hierbei kommen Zement- und Anhydritestriche, sowie unterschiedliche Dämmmaterialen mit variierenden Schichtdicken zum Einsatz. Wesentlicher Bestandteil der Auswertung ist die Extraktion signifikanter Signalmerkmale des Radarverfahrens, welche Rückschlüsse auf den Schadensfall und ggf. die Wassermenge zulassen. Weiterführend sollen die Kombinationsmöglichkeiten der verschiedenen Signalmerkmale und der Neutronensondendaten durch Methoden der multivariaten Datenauswertung und des maschinellen Lernens geprüft werden. Die Unabhängigkeit gegenüber wechselnden Schichtdicken und Materialien steht hierbei besonders im Fokus und soll anhand der erzielten Ergebnisse evaluiert werden.
In this ongoing research project, we study the influence of moisture damage on Ground Penetrating Radar (GPR) in different floor constructions. For this purpose, a measurement setup with interchangeable layers is developed to vary the screed material (cement or anhydrite) and insulation material (glass wool, perlite, expanded and extruded polystyrene), as well as the respective layer thickness. The evaluation of the 2 GHz common-offset radar measurements is focused on the extraction of distinctive signal features that can be used to classify the underlying case of damage without any further information about the hidden materials or layer thicknesses. In the collected dataset, we analyze the horizontal distribution of A-scan features in corresponding B-scans to detect water in the insulation layer. Furthermore, possible combinations of these features are investigated with the use of multivariate data analysis and machine learning (logistic regression) in order to evaluate the mutual dependencies. In this study, the combination of an amplitude- and frequency-based feature achieved an accuracy of 93.2 % and performed best to detect a damage in floor insulations.
Related work
Laboratory Study:
Combining Signal Features of Ground-Penetrating Radar to Classify Moisture Damage in Layered Building Floors
https://doi.org/10.3390/app11198820
On-Site Study:
TBA
Doctoral Thesis:
Non-destructive classification of moisture deterioration in layered building floors using ground penetrating radar
https://doi.org/10.14279/depositonce-19306
Measurement Parameters
The GPR measurements were carried out with the SIR 20 from GSSI and a 2 GHz antenna pair (bandwidth 1 GHz to 3 GHz) in common-offset configuration. Each B-Scan consists of N A-Scans, each including 512 samples of a 11 ns time window. Survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan No Gains were applied.
Folder Description:
Lab_dry, Lab_insulDamage, Lab_screedDamage
- each contain 168 Measurements (B-Scans) in .csv on 84 dry floors, floors with insulation damage and screed damage.
- each floor setup was measured twice on two orthogonal survey lines, indicated by _Line1_ and _Line2_ in the file name.
- the file names encode the building floor setup e.g. CT50XP100 describes a 50 mm cement screed with 100 mm extruded polystyrene below
- the material codes are
CT: cement screed, CA: anhydrite screed, EP: expanded polystyrene, XP: extruded polystyrene, GW: glass wool, PS: perlites
further information can be found in the publication https://doi.org/10.3390/app11198820
OnSite_
- 5 folders containing B-Scans on 5 different practical moisture damages
- the building floor setup is encoded according to the lab with an additional measurement point numbering at the start and a damage case annotation at the end of the file name with _dry, _insulationDamage and_screedDamage
File Description:
B-Scans, Measurement files - no header
- dimension: 512 x N data point with N beeing the number of A-Scans including 512 samples of a 11 ns time window.
- survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan
Moisture References
- Moist_Reference of On-Site Locations include the columns MeasPoint: Measurement point, wt%Screed: moisture content of screed layer in mass percent; wt%Insul: moisture content of insulation layer in mass percent. References were obtained by drilling cores with 68 mm diameter in the center of each survey line.
- Moist_Reference_Screed of Lab data include the columns Screed: Screed material and thickness in mm, wt%Screed moisture content of screed layer in mass percent
- Moist Reference_Insul of Lab data include the columns Insulation: Insulation material and thickness in mm, water addition in l: water added to the insulation layer in liters, V%Insulation: water added to the insulation layer in volume percent, RH%: resulting relative humidy in the insulation layer during measurement. These References are only avaible for Lab measurements on insulation damages.
Die Bestimmung der Belegreife von Estrichen erfolgt im Bauwesen meist unter Verwendung von zerstörenden Verfahren, die Probenentnahmen erfordern und nur punktuelle Daten liefern. Bei anhydritgebundenen Estrichen gelten 0,5 M% und bei zementgebundenen ca. 3,5 M% und höher als belegreifer Feuchtegehalt. Die Belegreife wird als Feuchtegehalt in Masseprozent (M%) bezogen auf die Trockenmasse des Baustoffes angegeben. Zur zerstörungsfreien Feuchtemessung existieren verschiedene einfach zu bedienende Handgeräte, die u. a. auf elektrischen, elektromagnetischen und kapazitiven Methoden beruhen. In dieser Arbeit wurden ein kapazitives (Kugelsonde), ein elektromagnetisches (Mikrowellensensoren) und ein elektrisches Messverfahren (Vierelektroden-Sonde) untersucht. Mit Ausnahme der Vierelektroden-Sonde weisen die Handgeräte keine ausreichende Sensitivität in Bereichen niedriger Feuchtegehalte unterhalb von 1 M% auf und scheinen somit nicht für anhydritgebundene Estriche geeignet zu sein. Für zementgebundene Estriche lassen sich hingegen mit allen getesteten Geräten Änderungen in dem Bereich der Belegreife erfassen. In dieser Arbeit wird zusätzlich die Wasserabgabe in g/m²/Tag als Bezugsgröße herangezogen. Die Wasserabgabe stellt ein geeigneteres Maß für die Schadensträchtigkeit dar und ermöglicht direkte Vergleiche unabhängig von der verwendeten Estrichart. Für alle getesteten Estriche konnte eine Wasserabgabe von ca. 8-10 g/m²/Tag als Belegreifegrenzwert bestimmt werden.
Die Ermittlung der Belegreife von Fußbodenestrichen ist im Bauwesen von hoher Bedeutung,
da es bei dem Verlegen von Parkett oder anderen Bodenbelägen auf Estrichen zu erheblichen
feuchtigkeitsbedingten Schäden kommen kann, wenn diese noch nicht hinreichend
getrocknet sind. Für die Messung des Feuchtegehalts wird üblicherweise auf zerstörende
Methoden wie das Darr- und CM-Verfahren zurückgegriffen, die Probennahmen erfordern
und nur punktuelle Informationen liefern.
Ziel dieser Forschungsstudie ist die Untersuchung der Eignung und Anwendbarkeit des
Georadars und der Kernspinresonanz (NMR) zur zerstörungsfreien und flächendeckenden
Feuchtemessung von Estrichen. Dazu wurden Messungen mit beiden Verfahren an einer
Gruppe zementgebundener (CT) und einer Gruppe anhydritgebundener (CA) Estriche
während ihres Austrocknungsprozesses bei einem Konstant-Klima durchgeführt. Bei dem
Radarverfahren werden Amplitude und Laufzeit elektromagnetischer Reflexionen, die durch den Wassergehalt beeinflusst werden, gemessen. Die Radarmessungen erfolgten auf jeder
Probe entlang von zwei senkrechten Profilen mit einer 2GHz-Antenne. Die Kernspinresonanz
steht aufgrund ihrer Abhängigkeit zur magnetischen Kernresonanz der 1H-Wasserstoffatomen
in Relation mit dem Wassergehalt in dem Messvolumen der zu untersuchenden
Probe. Die Untersuchungen erfolgten mit dem NMR MOUSE System in Aufsatztechnik.
Dabei liegt die Eindringtiefe bei 24,8 mm.
Bei den Untersuchungen lässt sich für CT-Estriche ein starker vertikaler Feuchtegradient
feststellen. Die CA-Estriche weisen hingegen nur einen schwachen Feuchtegradienten bis
nahezu konstante Amplituden über die gesamte Tiefe auf. Nach Erreichen einer Amplitude
von ca. 5-8 lässt sich keine weitere Amplitudenveränderung registrieren bzw. sind ab diesen
Zeitpunkt die Änderungen im Wassergehalt zu gering, um von der NMR aufgelöst zu werden.
In den Ergebnissen des Radarverfahrens lässt sich ebenfalls ein von dem Feuchtegehalt
abhängiges Verhalten der Messparameter beobachten. Mit zunehmender Trocknung kann
man eine Abnahme der Laufzeit zwischen direkter und an der Rückwand reflektierter Welle
messen. Die Amplituden beider Wellen hingegen nehmen während des Austrocknungsprozesses
zu. Im Gegensatz zur NMR erhält man keine tiefenbezogenen Informationen.
Es lassen sich aber Rückschlüsse auf den Feuchtegehalt im Gesamtvolumen ziehen.
We have compared the performance of the typical Darr and CM moisture testing techniques, which are destructive with several non-destructive testing techniques on two types of floor screeds. In case of cement based screeds these destructive tests failed to deliver reliable results. Moreover, our measurements indicate significantly different drying and moisture transport behavior for the investigated cement based and calcium-sulphate based screeds. Whereas we have strong with depth decreasing moisture gradients in the CT material, we observe in the penetrated volumes of our ndt methods basically no clear moisture gradient in the CA samples. The findings with ndt methods could be supported by moisture gradient studies with nuclear magnetic resonance measurements.
We present a preliminary investigation on distributed humidity monitoring during the drying process of concrete based on an embedded polymer optical fiber (POF). The water dissipated into the POF changes several properties of the fiber such as refractive index, scattering coefficient and attenuation factor, which eventually alters the Rayleigh backscattered light. The optical time Domain reflectometer (OTDR) technique is performed to acquire the backscattered signal at the wavelengths 650 nm and 500 nm, respectively. Experimental results show that the received signal increases at 650 nm while the fiber attenuation factor clearly increases at 500 nm, as the concrete dries out. In the hygroscopic range, the information retrieved from the signal change at 650 nm agrees well with the measurement result of the electrical humidity sensors also embedded in the concrete sample.
High-Amplitude Surge of a Pitching Airfoil: Complementary Wind- and Water-Tunnel Measurements
(2018)
RECENT interest in gust response, rotorcraft forward flight and wind energy, among other applications, has focused on streamwise oscillations of nominally two-dimensional airfoils in attached and separated flows. The airfoil may be simultaneously held at constant incidence or execute some maneuver, such as pitch.
The relative freestream is spatially uniform but temporally unsteady, and this can be accomplished in a ground-test facility in two ways. The first method is to vary the output of the prime mover, such as the rotational speed of the impeller or the blower driving a wind tunnel, or (alternatively) to vary the pressure drop in the tunnel, thereby varying the flow speed in the test section, despite nominally constant primemover revolutions per minute. The second method is used to keep the tunnel’s operating speed constant, as well as to move the test article in the streamwise direction, fore and aft (for example, via an electric linear motor), such that the relative freestream speed felt by the test article varies according to some waveform. Typically, the latter approach is chosen in water tunnels, where there is too much tunnel-circuit inertia to vary the flow speed directly but where the usually low tunnel test section flow speeds enable large excursions in the relative freestream by oscillation of the test article. In fact, outright reverse flow is possible by moving the test article in the laboratory frame at a higher speed than the water-tunnel flow speed. In either case, a sinusoidal relative-speed waveform is the most intuitively realizable, and this can be combined with similar oscillations in the airfoil incidence angle or other kinematics. Although the two methods of realizing streamwise oscillations are mechanically distinct, experimental comparisons between an oscillating test article in a water tunnel and a stationary test article in a wind tunnel with a louvermechanismhave demonstrated agreement in themeasured lift and drag histories. Such experimentswere performed by Granlund et al. for a 10% freestream amplitude oscillation and fixed airfoil incidence, comparing a free-surface water tunnel and a closed-circuit wind tunnel. After buoyancy was subtracted from the wind-tunnel data (resulting from the louver pressure drop) and the model inertia subtracted from the water-tunnel data (resulting from acceleration of the test article), the remaining lift and drag histories matched well at the low freestream oscillation amplitude regime. The work of Granlund et al. was later extended to high-advance-ratio streamwise oscillations of 50% amplitude by Greenblatt et al., where the aerodynamic histories of the water-tunnel and wind-tunnel facilities were compared in combined pitch and freestreamoscillations (governed by relative pitch phase), pure pitch oscillations, and purely freestream oscillations. Agreement between the two facilities’ data for fixed-incidence streamwise oscillations was reasonably good, and in fact, better than agreement in just the static lift and drag, evidently owing to differences in blockage and model-support systems. Additionally, Greenblatt et al. determined there was no strong coupling between simultaneous freestream oscillations and pitch oscillations on resultant lift and moment coefficients.
The development of prevention methods and the detection of moisture related damages in buildings and transport infrastructure at an early stage are current issues in the field of non-destructive testing in civil engineering.
Especially the subject of partial saturation requires further research since it is more likely to occur than full saturation of the material. In fact, partial saturation in porous media is even more complicated because both fully and partly saturated pores (i.e. pores in which the surfaces are covered with thin water layers) are present.
As the non-destructive method nuclear magnetic resonance (NMR) enables the measurement and quantification of relative low moisture contents, it is suitable for the investigation of partly saturated porous building materials. Nevertheless, the differentiation between partly and fully saturated pores is still a challenge. Therefore, in this study, we investigate two sandstones types (Bozanov and Schönbrunner sandstone) at various defined saturation states by using NMR. Furthermore, we measure the relative humidities within the samples and compute the water layer thicknesses (WLT) along the pore walls of all pore sizes to calculate the corresponding degree of pore saturation. To finally assign the NMR signals to pore sizes and to differentiate between partly and fully saturated pores, the water content distribution obtained from the WLT calculation is used for calibration of the relaxation-time distribution. In this extended abstract, selected results only for Schönbrunner sandstone are presented.
NMR is gaining increasing interest in civil engineering applications for the use of microstructure characterization as e.g. pore size determination and monitoring of moisture transport in porous materials. In this study, the use of NMR as a tool for pore size characterization was investigated. For our study we used screed and synthetic materials at partial and full saturation. A successful determination could be achieved when having a reference or calibration method, although partly diffusion effects have been registered. Due to these diffusion effects, for the determination of pore size distributions of synthetic materials another NMR device was needed. Finally, the determination of the surface relaxivity of screed (50 μm/s) led to a higher value than first expected from literature.
Since nuclear magnetic resonance with focus on 1H protons is highly sensitive to pore filling fluids, it is nowadays often applied for the investigation of porous media. Mainly in materials research and especially in the field of non-destructive testing in civil engineering it is increasingly used. Scientific questions about and based on NMR meanwhile cover a broad spectrum. To give an overview, we have reviewed various studies dealing with the determination of moisture contents and parameters such as the pore-size distribution, surface relaxivity, porosity, etc. In some papers, the monitoring of moisture transport in connection with degradation processes or admixtures was the main objective. In other papers, NMR was used for pore space analysis or even applied on site to assess the state of conservation of cultural heritage. Building materials that have been investigated in the presented studies are for example cement, concrete, woods, sandstones etc. In this paper, short descriptions and the significant results of the reviewed articles are summarized and their measurement problems and discrepancies are pointed out. A special feature of this review article is the concise tabular compilation of determined 𝑇1 and 𝑇2 relaxation times, as well as of surface relaxivity values for various materials and components. Finally, relevant aspects are summed up and conclusions about the increasing potential of NMR relaxometry for investigations of porous building materials are drawn, followed by an outlook about future applications and the need for technical development.
Dynamic stall often occurs under conditions of simultaneous unsteady pitching and surging (e.g., rotorcraft and wind turbines), butmanymodels employ a dimensionless time base that implicitly assumes that surging is superimposed, in a quasi-steady manner, on dynamic pitching. An unsteady wind tunnel was used to examine this assumption, where a technique was developed to quantify the unsteady effects of surging on a pitching NACA 0018 airfoil. The technique involved performing multiple harmonic pitching experiments under nominally steady freestream conditions that bracketed a corresponding 50% surging amplitude (1.25 ⋅ 105 ≤ Re ≤ 3.75 ⋅ 105). By interpolating these data, unsteady-pitching/quasi-steady-surging data sets were constructed and compared with de facto synchronous pitch and surging experiments, thereby isolating the unsteady effects of surging on a pitching airfoil. Both large and small poststall maximum angles of attack (αs + 5° and αs + 15°) were considered at multiple pitch-surge phase differences. During deep dynamic stall (αs 15°), with large-scale separation, surging was seen to have a secondary effect on the unsteady aerodynamics. However, at small poststall maximum angles of attack (αs + 5°), either light or deep dynamic stall behavior was observed depending upon the pitch-surge phase difference. This was attributed to Reynolds number history effects, exemplified by boundary-layer transition, and thus it can be referred to as “transitional” dynamic stall.
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
Ultrasonic methods are used in concrete investigations since decades. While being limited to transmission testing in the laboratory for a while, in-situ echo measurements for structural investigations and condition assessment have made their way into practical application in the past 20 years. However, several challenges remain. On one side, there are technical issues as limitations in depth of penetration, resolution and imaging capabilities. On the other side there are still gaps in validation, standardization and certification, which are limiting the applicability in condition/load capacity assessment.
This review reports a couple of developments which will help to overcome these issues. This includes technical developments as new devices which are easier to handle on site or giving a much deeper penetration depth (e.g. the LAUS device at BAM) as well as improvements in imaging by hardware update (e. g. air coupled ultrasound or coded signals) or new software (e. g. RTM imaging). To foster the application in real world projects we are as well working on standardization by developing new reference specimen with international partners which will ensure world-wide comparability of ultrasonic and other methods and quality assurance codes. Further, non-destructive methods are being used to update probabilistic models used for the reassessment of existing structures to support the structural engineer’s decisions.
Additive manufacturing of concrete structures is a novel and emerging technology. Freecontouring in civil engineering, which allows for entirely new designs, is a significant advantage. Inthe future, lower construction costs are expected with increased construction speeds and decreasingrequired materials and workers. However, architects and civil engineers rely on a certain quality ofexecution to fulfil construction standards. Although several techniques and approaches demonstratethe advantages, quality control during printing is highly challenging and rarely applied. Due to thecontinuous mixing process commonly used in 3D concrete printing, it is impossible to exclude varia-tions in the dry mixture or water content, and a test sample cannot be taken as a representative samplefor the whole structure. Although mortar properties vary only locally, a defect in one layer duringprinting could affect the entire integrity of the whole structure . Therefore, real-time process monitor-ing is required to record and document the printing process.At the Bundesanstalt für Materialforschung und -prüfung (BAM) a new test rig for the additive man-ufacturing of concrete is built. The primary purpose is measuring and monitoring the properties of amortar during the printing process.The following study investigates an approach for calculating yield stress and plastic viscosity based onexperimentally recorded pressure data. The calculations assume that fresh mortar behaves as a Bing-ham fluid and that the Buckingham-Reiner-equation is applicable. A test setup consisting of rigid pipeswith integrated pressure sensors at different positions is utilized.Monitoring the printing process with different sensors is crucial for the quality control of an ongoingprocess.
The effective gas diffusion coefficient describes the process of gas diffusion in porous materials. Several materials have a significant number of micropores in the lower nanometre range leading to a reduction of gas diffusion (Knudsen effect). In the case of partial pore saturation during adsorption, the available pore space is further reduced, as is the gas diffusion. In this study, the influence of partially saturated pores on the Knudsen effect and on the gas diffusion is quantified. Three different pore geometries are investigated (slit, cylindrical and spherical pores) and three different types of pore size distribution, including a broad equal distribution, three narrow normal distributions and two measured distributions of concrete.
Besides the intensive computation of the exact pore saturation, a simplified model with low computational requirements is suggested. This study shows that the influence of the water layer thickness on the effective diffusion becomes significant for pore radii below 50 nm and the assumed pore geometry is important. At the end, the overall effect is quantified for an amorphous material with most pore
radii below 30 nm. At a moisture level of 50% relative humidity, the effective diffusion is reduced by 35% due to partial saturation.
Several countries, which use or used nuclear power, started to destruct nuclear power plants. Thus, large amounts of radioactive waste have to be stored safely during the next decades. Large underground caverns will
be used a nuclear waste disposal. Once the cavern is full, a sealing construction is required. The sealing should avoid the contact to any fluids or substances of the storage barrels and reduce hazardous radiation.
Introduction of a monitoring system for Bingham fluids in additive manufacturing with concrete
(2022)
Freeform additive manufacturing of concrete structures is a rising technology in civil engineering with several fascinating advantages. Nonetheless, to ensure reliability and structural integrity, standards and quality control are required in the future to bring this technology into the market. As the concrete is manufactured continuously, continuous quality control of the printing process is also required, i.e. comprehensive process monitoring. At BAM, a test rig will be installed, enabling the printing of concrete structures with a maximum size of 2 m x 1 m x 1 m (l x w x h). Here, process monitoring is the focus of the test rig. In this study, we show the results of the first pump tests, including the measurement of several parameters such as temperature and pressure along the supply system, i.e. from the concrete pump to the printer head.
Eight different screed types are tested including two different sample heights of 35 and 70 mm. The moisture of the four cement based and four sulphate based screeds are monitored during hydration and evaporation. All samples are stored in a climatic chamber at 23° C and 50 % relative humidity. Embedded sensors like temperature arrays, humidity sensor arrays, and multi-ring electrodes are embedded in the samples to yield a detailed moisture evolution with high depth resolution. Furthermore, nuclear magnetic resonance is used to quantify the water content at different depths. This multi-sensor approach allows a comprehensive monitoring of the moisture and its gradient in the different screed samples. This yields a deeper insight into the hydration, moisture convection, and diffusion processes.
To quantify the moisture in concrete, RFID based humidity sensors are embedded. Passive high frequency, ultra-high frequency RFID tags as well as active Bluetooth sensors are tested. After concreting, all sensors measure the corresponding relative humidity to monitor the concrete moisture. Two case studies are performed, embedding in an existing construction, i.e. the duraBASt test bridge, and embedding in cement based mortar in the laboratory. As basis for robust and long-life sensors in alkaline concrete, different casing materials are tested. Furthermore, signal strength measurements and their sensitivity to different moisture levels are performed.
In the near future, it will be important to adopt innovative approaches and technologies in order to further guarantee the reliability and availability of the highway network. New tools are therefore needed in order to obtain in-depth information about the condition of bridges and its development early enough before significant, precarious damage cases occur. In 2011, the research program “Intelligente Brücken (Smart Bridges)” was launched by the BASt together with the BMVI to evolve systems for information and holistic evaluation for Bridge structures as a supplement to the current inspection-based maintenance management. Several projects dealt with the topic in the last few years and provided guidelines and a solid basis to move towards a first implementation considering the input of all research projects carried out so far.