Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (36)
- Vortrag (31)
- Beitrag zu einem Tagungsband (26)
- Posterpräsentation (10)
- Sonstiges (4)
- Beitrag zu einem Sammelband (1)
- Forschungsbericht (1)
- Forschungsdatensatz (1)
Schlagworte
- Material moisture (19)
- Embedded sensors (15)
- Non-destructive testing (13)
- Building materials (12)
- Structural health monitoring (12)
- Concrete (11)
- Air-coupled ultrasound (10)
- RFID sensors (9)
- Moisture (8)
- RFID based sensors (8)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (76)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (70)
- 8.0 Abteilungsleitung und andere (8)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (7)
- 7 Bauwerkssicherheit (6)
- 7.2 Ingenieurbau (3)
- 7.4 Baustofftechnologie (3)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.2 Biophotonik (1)
- 8.6 Faseroptische Sensorik (1)
Eingeladener Vortrag
- nein (31)
-Über 80 Mio. Schwellen im deutschen Schienennetz verbaut
-Lebensdauer einer Schwelle beträgt ca. 20 bis 50 Jahre
-Über 2 Mio. Schwellen werden jährlich ausgetauscht, obwohl die Mehrzahl noch intakt ist
-Zustandsbewertung mittels ZfP kann Ausschuss verringern
-Schadhafte Schwellen könnten mittels ZfP frühzeitig im Gleis erkannt werden, um Gefahren und Unfälle abzuwenden
Das Neutronensondenverfahren wird bereits seit vielen Jahren erfolgreich zur Eingrenzung und Quantifizierung auftretender Feuchteschäden an Fußböden eingesetzt. Hierzu bedarf es jedoch einer Vielzahl zerstörender Sondierungsbohrungen, welche die gewonnenen Messdaten kalibrieren und eine Tiefenzuordnung des Flüssigwassers zulassen. Dadurch entsteht ein zeitlicher und finanzieller Aufwand, der durch den parallelen Einsatz des elektromagnetischen Radarverfahrens vermieden werden könnte. Mit seiner hohen Sensitivität für Wasser bietet diese Messmethode die Möglichkeit der vertikalen Lokalisierung von Feuchte, was zu einer automatisierten Klassifizierung typischer Schadensfälle beitragen soll.
In einem laufenden Forschungsvorhaben werden in systematischen Laborstudien gängige Schadensfälle an häufig anzutreffenden Fußbodenaufbauten simuliert und deren Einfluss auf die genannten Verfahren untersucht. Hierbei kommen Zement- und Anhydritestriche, sowie unterschiedliche Dämmmaterialen mit variierenden Schichtdicken zum Einsatz. Wesentlicher Bestandteil der Auswertung ist die Extraktion signifikanter Signalmerkmale des Radarverfahrens, welche Rückschlüsse auf den Schadensfall und ggf. die Wassermenge zulassen. Weiterführend sollen die Kombinationsmöglichkeiten der verschiedenen Signalmerkmale und der Neutronensondendaten durch Methoden der multivariaten Datenauswertung und des maschinellen Lernens geprüft werden. Die Unabhängigkeit gegenüber wechselnden Schichtdicken und Materialien steht hierbei besonders im Fokus und soll anhand der erzielten Ergebnisse evaluiert werden.
Die Ermittlung der Belegreife von Fußbodenestrichen ist im Bauwesen von hoher Bedeutung,
da es bei dem Verlegen von Parkett oder anderen Bodenbelägen auf Estrichen zu erheblichen
feuchtigkeitsbedingten Schäden kommen kann, wenn diese noch nicht hinreichend
getrocknet sind. Für die Messung des Feuchtegehalts wird üblicherweise auf zerstörende
Methoden wie das Darr- und CM-Verfahren zurückgegriffen, die Probennahmen erfordern
und nur punktuelle Informationen liefern.
Ziel dieser Forschungsstudie ist die Untersuchung der Eignung und Anwendbarkeit des
Georadars und der Kernspinresonanz (NMR) zur zerstörungsfreien und flächendeckenden
Feuchtemessung von Estrichen. Dazu wurden Messungen mit beiden Verfahren an einer
Gruppe zementgebundener (CT) und einer Gruppe anhydritgebundener (CA) Estriche
während ihres Austrocknungsprozesses bei einem Konstant-Klima durchgeführt. Bei dem
Radarverfahren werden Amplitude und Laufzeit elektromagnetischer Reflexionen, die durch den Wassergehalt beeinflusst werden, gemessen. Die Radarmessungen erfolgten auf jeder
Probe entlang von zwei senkrechten Profilen mit einer 2GHz-Antenne. Die Kernspinresonanz
steht aufgrund ihrer Abhängigkeit zur magnetischen Kernresonanz der 1H-Wasserstoffatomen
in Relation mit dem Wassergehalt in dem Messvolumen der zu untersuchenden
Probe. Die Untersuchungen erfolgten mit dem NMR MOUSE System in Aufsatztechnik.
Dabei liegt die Eindringtiefe bei 24,8 mm.
Bei den Untersuchungen lässt sich für CT-Estriche ein starker vertikaler Feuchtegradient
feststellen. Die CA-Estriche weisen hingegen nur einen schwachen Feuchtegradienten bis
nahezu konstante Amplituden über die gesamte Tiefe auf. Nach Erreichen einer Amplitude
von ca. 5-8 lässt sich keine weitere Amplitudenveränderung registrieren bzw. sind ab diesen
Zeitpunkt die Änderungen im Wassergehalt zu gering, um von der NMR aufgelöst zu werden.
In den Ergebnissen des Radarverfahrens lässt sich ebenfalls ein von dem Feuchtegehalt
abhängiges Verhalten der Messparameter beobachten. Mit zunehmender Trocknung kann
man eine Abnahme der Laufzeit zwischen direkter und an der Rückwand reflektierter Welle
messen. Die Amplituden beider Wellen hingegen nehmen während des Austrocknungsprozesses
zu. Im Gegensatz zur NMR erhält man keine tiefenbezogenen Informationen.
Es lassen sich aber Rückschlüsse auf den Feuchtegehalt im Gesamtvolumen ziehen.
Ultrasonic testing is a widely applied measurement method in materials research and medicine. Commonly, a transducer is coupled to the specimen directly or via a liquid coupling agent. While reducing acoustic transmission losses significantly, this procedure is time-consuming and cannot be used for sensitive specimens. Air-coupled ultrasound is a viable alternative in such cases, although suffering from very high acoustic transmission losses between transducer, air and specimen. The recently introduced fluidic transducer (FT) generates ultrasound by utilizing the instability of a supersonic air jet switched inside a fluidic amplifier. Since only air is used as the working medium and no vibrating surfaces are used for ultrasound generation, the transducer is able to efficiently generate large acoustic pressure amplitudes. The resulting acoustic field shares its directivity with the ejected high-velocity air jet. Thus, the acoustic energy needs to be redirected from the jet axis in order to make the fluidic transducer applicable to sensitive specimens. In this study, the effectivity of using sonic crystals (SCs) for this redirection is investigated using acoustic and flow measurements. SCs are air-permeable while being reflective to large acoustic frequency bands. It was shown that both a defect waveguide and a mirroring strategy successfully redirected the acoustic field from the air jet. Furthermore, the interaction of flow and SC showed strong acoustic quenching if the SC was placed too close to the FT outlet. Blockage of the jet entrainment due to the SC may result in slightly higher off-axis flow velocities locally, which should be considered in sensitive applications.
Ultraschallmessverfahren werden seit Langem erfolgreich für Prüfaufgaben im Bauwesen eingesetzt. Die dauerhafte Überwachung und frühzeitige Erkennung von Schäden an komplexen Neubauten und alternder Infrastruktur kann mittels Ultraschall-Transmissionsmessungen und speziellen Auswertemethoden, wie z. B. Korrelationverfahren und Codawelleninterferometrie, realisiert werden. Für die Dauerüberwachung wurde ein kompaktes System entwickelt, das Ultraschall-Messdaten erfassen und ins Internet auf einen FTP-Server übertragen kann. Es können hierbei alle angeschlossenen Prüfköpfe für jede Messung wahlweise als Sender oder Empfänger geschaltet werden. Es wurden Vorverstärker entwickelt, bei denen die Versorgung mit Strom über die Messleitung erfolgt. Dadurch können die Verstärker nahe am Prüfkopf positioniert werden. Durch Änderungen in den Ultraschall-Signalen können Schädigungen des Bauteils, wie z.B. Risse, in Echtzeit erkannt werden.
Completely embedded sensor systems for long-term
operation offer innovative possibilities for structural health
monitoring of concrete structures. Measuring of relevant
parameters, e.g., temperature, humidity, or indication of
corrosion can be performed with low energy sensors. This allows
to implement passive RFID sensor systems without cable
connection and battery, which are power supplied exclusively by
the electromagnetic field from the external reader device. To
evaluate characteristics and conditions of this concept, a
systematical investigation of the transmission characteristics with
variation of relevant parameters, as communication frequency,
installation depth, type of concrete, moisture content, etc. is
currently carried out in an interdisciplinary research project at
BAM. First results are presented in this paper.
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
In civil engineering, many structures are made of reinforced concrete. Most Degradation processes relevant to this material, e.g., corrosion, are related to an increased level of material moisture.
Therefore, moisture monitoring in reinforced concrete is regarded as a crucial method for structural health monitoring. In this study, passive radio frequency identification (RFID)-based sensors are embedded into the concrete. They are well suited for long-term operation over decades and are well protected against harsh environmental conditions. The energy supply and the data transfer of the humidity sensors are provided by RFID. The sensor casing materials are optimised to withstand the high alkaline environment in concrete, having pH values of more than 12. Membrane materials are also investigated to identify materials capable of enabling water vapour transport from the porous cement matrix to the embedded humidity sensor. By measuring the corresponding relative humidity with embedded passive RFID-based sensors, the cement hydration is monitored for 170 days.
Moreover, long-term moisture monitoring is performed for more than 1000 days. The Experiments show that embedded passive RFID-based sensors are highly suitable for long-term structural health monitoring in civil engineering.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
The duraBASt area at the highway intersection “Köln-Ost” is a large test field for road testing.
It includes the duraBASt test bridge which is approximately 66 m long and 14.25 m broad. This bridge is part of the “road in the 21st Century” project and is equipped with several sensors for structural health monitoring. This feasibility study is carried out to investigate the prerequisites necessary for the constraction of intelligent bridges in the foture. Embedded sensors are able to measure quantities such as temperature, strain, moisture, corrosion, etc. In the presented work, the focus is set on passive RFID-based sensors. The communication and energy supply are realised by a mobile transmitter through the concrete cover. Hence, no cables or batteries are required. The sensors are designed to withstand the alkaline environment in concrete. Thus, moisture and corrosion values are measurable for several decades.
Das vorliegende Arbeitspapier stellt den Stand des Wissens und der Forschung zum Einsatz von Sensorik in Straßenbefestigungen zur Erfassung von Eingangsgrößen und Merkmalen für die Substanzbewertung zusammenfassend dar. Unter Sensorik versteht dieses Arbeitspapier ganz allgemein technische Einrichtungen, mit denen man die Werte von physikalischen Größen erfassen und zur Interpretation darstellen kann.