Filtern
Dokumenttyp
- Zeitschriftenartikel (4)
- Beitrag zu einem Tagungsband (2)
- Vortrag (1)
Schlagworte
- Moisture (3)
- NMR (3)
- Building materials (2)
- Estrich (2)
- NMR relaxometry (2)
- Screed (2)
- 4-electrode probe (1)
- Adsorbed water layer thickness (1)
- Amorphous materials (1)
- Calcium carbide method (1)
- Calcium-Carbid-Methode (1)
- Capacitive spherical probe (1)
- Corresponding relative humidity (1)
- Embedded sensors (1)
- Feuchte (1)
- Feuchtemessung (1)
- Georadar (1)
- Kapazitive Kugelsonde (1)
- Macropores (1)
- Material moisture (1)
- Mesopores (1)
- Microwave (1)
- Mikrowellensensoren (1)
- Moisture distribution (1)
- Natural stones (1)
- Non-destructive testing (1)
- Partial pore saturation (1)
- Physisorption (1)
- Pore size distribution (1)
- Pore space characterization (1)
- Pore-size distribution (1)
- Porous materials (1)
- Readiness for covering (1)
- Relative humidity (1)
- Relaxation times (1)
- Surface relaxivities (1)
- Surface relaxivity (1)
- Vierelektroden-Sonde (1)
- Water layer thickness (1)
- Zerstörungsfreie Prüfung (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
Die Bestimmung der Belegreife von Estrichen erfolgt im Bauwesen meist unter Verwendung von zerstörenden Verfahren, die Probenentnahmen erfordern und nur punktuelle Daten liefern. Bei anhydritgebundenen Estrichen gelten 0,5 M% und bei zementgebundenen ca. 3,5 M% und höher als belegreifer Feuchtegehalt. Die Belegreife wird als Feuchtegehalt in Masseprozent (M%) bezogen auf die Trockenmasse des Baustoffes angegeben. Zur zerstörungsfreien Feuchtemessung existieren verschiedene einfach zu bedienende Handgeräte, die u. a. auf elektrischen, elektromagnetischen und kapazitiven Methoden beruhen. In dieser Arbeit wurden ein kapazitives (Kugelsonde), ein elektromagnetisches (Mikrowellensensoren) und ein elektrisches Messverfahren (Vierelektroden-Sonde) untersucht. Mit Ausnahme der Vierelektroden-Sonde weisen die Handgeräte keine ausreichende Sensitivität in Bereichen niedriger Feuchtegehalte unterhalb von 1 M% auf und scheinen somit nicht für anhydritgebundene Estriche geeignet zu sein. Für zementgebundene Estriche lassen sich hingegen mit allen getesteten Geräten Änderungen in dem Bereich der Belegreife erfassen. In dieser Arbeit wird zusätzlich die Wasserabgabe in g/m²/Tag als Bezugsgröße herangezogen. Die Wasserabgabe stellt ein geeigneteres Maß für die Schadensträchtigkeit dar und ermöglicht direkte Vergleiche unabhängig von der verwendeten Estrichart. Für alle getesteten Estriche konnte eine Wasserabgabe von ca. 8-10 g/m²/Tag als Belegreifegrenzwert bestimmt werden.
Die Ermittlung der Belegreife von Fußbodenestrichen ist im Bauwesen von hoher Bedeutung,
da es bei dem Verlegen von Parkett oder anderen Bodenbelägen auf Estrichen zu erheblichen
feuchtigkeitsbedingten Schäden kommen kann, wenn diese noch nicht hinreichend
getrocknet sind. Für die Messung des Feuchtegehalts wird üblicherweise auf zerstörende
Methoden wie das Darr- und CM-Verfahren zurückgegriffen, die Probennahmen erfordern
und nur punktuelle Informationen liefern.
Ziel dieser Forschungsstudie ist die Untersuchung der Eignung und Anwendbarkeit des
Georadars und der Kernspinresonanz (NMR) zur zerstörungsfreien und flächendeckenden
Feuchtemessung von Estrichen. Dazu wurden Messungen mit beiden Verfahren an einer
Gruppe zementgebundener (CT) und einer Gruppe anhydritgebundener (CA) Estriche
während ihres Austrocknungsprozesses bei einem Konstant-Klima durchgeführt. Bei dem
Radarverfahren werden Amplitude und Laufzeit elektromagnetischer Reflexionen, die durch den Wassergehalt beeinflusst werden, gemessen. Die Radarmessungen erfolgten auf jeder
Probe entlang von zwei senkrechten Profilen mit einer 2GHz-Antenne. Die Kernspinresonanz
steht aufgrund ihrer Abhängigkeit zur magnetischen Kernresonanz der 1H-Wasserstoffatomen
in Relation mit dem Wassergehalt in dem Messvolumen der zu untersuchenden
Probe. Die Untersuchungen erfolgten mit dem NMR MOUSE System in Aufsatztechnik.
Dabei liegt die Eindringtiefe bei 24,8 mm.
Bei den Untersuchungen lässt sich für CT-Estriche ein starker vertikaler Feuchtegradient
feststellen. Die CA-Estriche weisen hingegen nur einen schwachen Feuchtegradienten bis
nahezu konstante Amplituden über die gesamte Tiefe auf. Nach Erreichen einer Amplitude
von ca. 5-8 lässt sich keine weitere Amplitudenveränderung registrieren bzw. sind ab diesen
Zeitpunkt die Änderungen im Wassergehalt zu gering, um von der NMR aufgelöst zu werden.
In den Ergebnissen des Radarverfahrens lässt sich ebenfalls ein von dem Feuchtegehalt
abhängiges Verhalten der Messparameter beobachten. Mit zunehmender Trocknung kann
man eine Abnahme der Laufzeit zwischen direkter und an der Rückwand reflektierter Welle
messen. Die Amplituden beider Wellen hingegen nehmen während des Austrocknungsprozesses
zu. Im Gegensatz zur NMR erhält man keine tiefenbezogenen Informationen.
Es lassen sich aber Rückschlüsse auf den Feuchtegehalt im Gesamtvolumen ziehen.
The development of prevention methods and the detection of moisture related damages in buildings and transport infrastructure at an early stage are current issues in the field of non-destructive testing in civil engineering.
Especially the subject of partial saturation requires further research since it is more likely to occur than full saturation of the material. In fact, partial saturation in porous media is even more complicated because both fully and partly saturated pores (i.e. pores in which the surfaces are covered with thin water layers) are present.
As the non-destructive method nuclear magnetic resonance (NMR) enables the measurement and quantification of relative low moisture contents, it is suitable for the investigation of partly saturated porous building materials. Nevertheless, the differentiation between partly and fully saturated pores is still a challenge. Therefore, in this study, we investigate two sandstones types (Bozanov and Schönbrunner sandstone) at various defined saturation states by using NMR. Furthermore, we measure the relative humidities within the samples and compute the water layer thicknesses (WLT) along the pore walls of all pore sizes to calculate the corresponding degree of pore saturation. To finally assign the NMR signals to pore sizes and to differentiate between partly and fully saturated pores, the water content distribution obtained from the WLT calculation is used for calibration of the relaxation-time distribution. In this extended abstract, selected results only for Schönbrunner sandstone are presented.
NMR is gaining increasing interest in civil engineering applications for the use of microstructure characterization as e.g. pore size determination and monitoring of moisture transport in porous materials. In this study, the use of NMR as a tool for pore size characterization was investigated. For our study we used screed and synthetic materials at partial and full saturation. A successful determination could be achieved when having a reference or calibration method, although partly diffusion effects have been registered. Due to these diffusion effects, for the determination of pore size distributions of synthetic materials another NMR device was needed. Finally, the determination of the surface relaxivity of screed (50 μm/s) led to a higher value than first expected from literature.
Since nuclear magnetic resonance with focus on 1H protons is highly sensitive to pore filling fluids, it is nowadays often applied for the investigation of porous media. Mainly in materials research and especially in the field of non-destructive testing in civil engineering it is increasingly used. Scientific questions about and based on NMR meanwhile cover a broad spectrum. To give an overview, we have reviewed various studies dealing with the determination of moisture contents and parameters such as the pore-size distribution, surface relaxivity, porosity, etc. In some papers, the monitoring of moisture transport in connection with degradation processes or admixtures was the main objective. In other papers, NMR was used for pore space analysis or even applied on site to assess the state of conservation of cultural heritage. Building materials that have been investigated in the presented studies are for example cement, concrete, woods, sandstones etc. In this paper, short descriptions and the significant results of the reviewed articles are summarized and their measurement problems and discrepancies are pointed out. A special feature of this review article is the concise tabular compilation of determined 𝑇1 and 𝑇2 relaxation times, as well as of surface relaxivity values for various materials and components. Finally, relevant aspects are summed up and conclusions about the increasing potential of NMR relaxometry for investigations of porous building materials are drawn, followed by an outlook about future applications and the need for technical development.
Eight different screed types are tested including two different sample heights of 35 and 70 mm. The moisture of the four cement based and four sulphate based screeds are monitored during hydration and evaporation. All samples are stored in a climatic chamber at 23◦ C and 50 % relative humidity. Embedded sensors like temperature arrays, humidity sensor arrays, and multi-ring electrodes are embedded in the samples to yield a detailed moisture evolution with high depth resolution. Furthermore, nuclear magnetic resonance is used to quantify the water content at different depths. This multi-sensor approach allows a comprehensive monitoring of the moisture and its gradient in the different screed samples. This yields a deeper insight into the hydration, moisture convection, and diffusion processes.
Amorphous, porous materials represent by far the largest proportion of natural and men-made materials. Their pore networks consists of a wide range of pore sizes, including mesoand macropores. Within such a pore network, material moisture plays a crucial role in almost all transport processes. In the hygroscopic range, the pores are partially saturated and liquid water is only located at the pore fringe due to physisorption. Therefore, material parameters such as porosity or median pore diameter are inadequate to predict material moisture and moisture transport. To quantify the spatial distribution of material moisture, Hillerborg’s adsorption Theory is used to predict the water layer thickness for different pore geometries. This is done for all pore sizes, including those in the lower nanometre range. Based on this approach, it is shown that the material moisture is almost completely located in mesopores, although the pore network is highly dominated by macropores. Thus, mesopores are mainly responsible for the moisture storage capacity, while macropores determine the moisture transport capacity, of an amorphous material. Finally, an electrical analogical circuit is used as a model to predict the diffusion coefficient based on the pore-size distribution, including physisorption.