The safety assessment of railway axles is based on a two-stage approach: fatigue strength design and regular inspections which, in terms of a general safety philosophy refer to safe-life and damage tolerance concepts. Starting with a recent failure case, a broken axle of a German high speed train, a discussion is presented on issues of both safety levels. These include ideas for finite life design, the treatment of in-service effects on the fatigue strength due to flying ballast damage and corrosion pits, the effect of corrosion on fatigue crack initiation and propagation, potential effects of non-metallic inclusions in steels, the way to detect them by quality control measures and reliability aspects of non-destructive testing with respect to the detection of fatigue cracks. Proposals are made how the safety level could be further improved.
The paper gives an overview on safe life and damage tolerance methods applied to railway axles. It describes failure scenarios due to fatigue crack initiation and propagation. Besides common aspects of design, specific features such as corrosion and impact damage from flying ballast are discussed which may reduce the fatigue strength of axles during service. Potential effects of non-metallic inclusions from the steel manufacturing process are addressed in the context of the very high number of loading cycles railway axles are designed for. With respect to damage tolerance general lines of fracture mechanics residual lifetime analyses are introduced. More specific discussion is provided on aspects such as the threshold value of fatigue crack propagation and reliability aspects of non-destructive inspection.
The paper provides an overview on material defects which may serve as fatigue crack initiation sites and can cause final fatigue failure of a component. These comprise nonmetallic inclusions in Steel and aluminum alloys, cavities such as pores, micro-shrinkages and un-welded regions in cast, sinter and additively manufactured alloys, graphite nodules, shrinkages and other items in modular cast iron, regions of defective microstructure, microcracks and secondary notches such as undercuts and surface roughness. Besides their origin, the effect and mechanisms on fatigue crack initiation and propagation are discussed.
The considerations are proceeded and accompanied by a Brief discussion of some Basic aspects such as the stages of crack propagation along their length scale, the overcoming of crack arrest and the question when a secondary notch can be treated as a crack.
Investigations on the breakdown of a heat recovery steam generator during the initial operation run
(2014)
Several years ago, in 2003, an industrial heat recovery steam generator in charge of generating process steam in a petrochemical refinery was installed and prepared for initial operation. The steam generator enclosed an evaporator section and a superheater section consisting mainly of bundles of tubes with the longest up to several metres in length. During initial operation test runs severe leakages in the evaporator and superheater modules became noticeable. The test runs were stopped and after disassembly, through-wall cracks in several tube bends were found. BAM was commissioned to carry out the investigations in order to find out the reasons for the failure of the tubes. During on-site inspection a number of relevant damaged components and parts were selected and taken away to the laboratories for detailed inspection. Planned analyses were to comprise metallographic as well as fractographic investigations, mechanical fatigue testing and experimental as well as finite element vibration analyses on specimens and components. Soon, the fracture mechanism was found to be mechanical fatigue due to the fact that the examined fracture surfaces showed the very characteristic beachmarks and colouring patterns. To identify the particular loading and time at which crack initiation and crack propagation took place, experimental and numerical vibration analyses of specific tubes as well as mechanical fatigue tests on tube bends were carried out. Thus it was possible to identify the eigenfrequencies of individual tubes, to estimate the dynamic response as well as the nominal stresses and, hence, experimentally characterise the in-service fatigue strength of the components. Mechanical and thermal comparative tests on tube bends were performed simulating the conditions during the initial test run in order to get crack surfaces comparable to that of the originally damaged components. Thereby it became obvious that the fatigue cracks were initiated by vibrations the tube bundles were exposed to during rail transport from the manufacturers site to the place of installation. Based on these results, the damaged components could be repaired or exchanged without modification of the construction, but the rules relating packaging and securing for shipping had to be revised.
The roll-on-roll-off passenger ferry MV ESTONIA sank during the night of 28 September 1994 in the Baltic Sea. In October 2000, divers recovered two palm-sized test pieces from the front bulkhead of the wreck. The investigators analysed these specimens to determine whether there were any indications of deliberate blasting. Since the wreck had been submerged for almost six years, it was clear that chemical traces would not be present on the surfaces of the test pieces. Therefore, the investigators performed comparative tests on shipbuilding steel to find a microstructural criterion that exclusively characterises a blast. The shipyard Jos. L. Meyer, Germany, had built the ESTONIA and supplied shipbuilding steel plates similar to that used for building the vessel in 1979/1980. The comparative tests comprised mechanical tests, shot peening tests and blasting tests using different explosives. Testing demonstrated that blasting always formed twinned ferrite grains in the microstructure over the whole cross-section of each of the 8 mm thick comparative plates. Although one of the original test pieces of the ESTONIA showed deformation twins, this was only confined up to 0.4 mm underneath the surfaces and not spread over the whole cross-section. Comparative shot peening tests produced the very same pattern of subsurface deformation twins. Therefore, the twins detected in the microsection of the test pieces of the ESTONIA wreck traced back to the shot peening process performed by the shipyard in 1979/1980 and not to a deliberate blast.
Although fatigue crack propagation and fracture cause a large part of failure events in industrial practice, fracture mechanics in failure analysis seems to be still a side issue. Starting from an introduction into important basic questions of failure analysis and fracture mechanics, the authors specify what kind of questions in failure analysis can be effectively solved by fracture mechanics (and which can't). They illustrate their discussion with a number of 13 case studies from the literature. Much more pronounced than in the design stage the benefit of fracture mechanics in failure analysis depends on its accuracy. This is limited by both, intrinsic factors of the method and the availability and quality of the input information. The authors discuss the various aspects and provide the reader with some background information which, as they believe, will be helpful for better understanding the prospects and limitations of fracture mechanics in failure analysis and the conditions of its application.
Unexpected wind-induced vibrations of the hangers have caused an early fatigue crack on specific steel components and joints of a railway bridge over the Elbe River at Lutherstadt Wittenberg, Germany. During regular periodic inspection a fatigue crack of approximately 240 mm length was found near a butt weld of the longest hanger. The hanger was immediately secured by welded butt straps across the crack. Based on experimental investigations of hanger vibrations additional bracings were added between the hangers to avoid wind-induced vibrations. The weld heat influence zone which was affected by high cyclic stresses was replaced by new material.
Nevertheless it was impossible to determine sufficient remaining service life for those remaining bridge components that were exposed to extreme high real load cycles. The grinding of the affected steel surfaces was the key element of the remedial actions. Furthermore, additional fracture mechanic calculations were carried out in order to assess the remaining service life of the welded joints. In this respect, the calculation approach used by Deutsche Bahn AG was compared to further procedures from the mechanical engineering field. These investigations showed that the studied, repaired components have both, bearing and fatigue capacities within the validity of standards.
Self-excited vibrations with large amplitudes in natural wind may occur at slender structural elements with low damping. Because of the different designs (e. g. using solid sections today instead of cables for tension elements in the past) the susceptibility to wind induced oscillations has increased. Those wind induced vibrations of profiles with specific cross section geometry which are motion induced and therefore self-exciting are called 'galloping vibrations'. Especially systems with elements that are highly tensile loaded and undamped, like hangers of bridges or tension bars of cranes, are sensitive to wind induced vibrations. Therefore more and more fatigue problems caused by galloping oscillations have occurred in the 1990s. This paper describes exemplary the collapses of two modern cranes of different design and manufacturers. During standstill periods, both cranes suffered from wind induced vibrations of the tension bars, which bear up the counterweights. The failure analysis process to identify and explain the fatigue fractures as well as the comparative experiments and simulation to verify that they were caused by wind induced galloping-vibrations is described. It is shown, which parameters led to galloping-vibrations of the tension bars and how their onset wind speed and the amplitudes can be estimated with more accuracy by a non-linear and non-stationary approach. Furthermore it is shown that such dynamic stresses caused fatigue failure of the tension bars for the counter weights and subsequently collapsing of the cranes.
For loss prevention knowledge and results gained by these investigations should be put at disposal to engineers working on this field of design. In the meantime, a contribution to development of appropriate technical standards on structural steelwork was given by the research works on galloping. Although new standards were introduced, which consider wind induced vibrations, such failures still occur. (Reference to the paper 'Fatigue crack in railway bridge hanger due to wind induced vibrations – failure analysis, measures and remaining service life estimation' in this same Special Issue 'A tribute to A. Martens' 2014).
End of November 2005 strong south-west wind and heavy snowfall were predominant in the region Münsterland, north-western part of Germany. This led to accretion of a considerable quantity of wet snow to overhead electrical lines in form of snow rolls on the conductors. Eighty-two transmission towers failed catastrophically, most of them by buckling, however some by brittle fracture. As a consequence nearly 250,000 people have been cut off from electrical power supply for several days with major media attention.
This paper describes the forensic analysis in order to investigate the failure cause. Therefore extensive materials investigations, mechanical testing of original components and specimens thereof, estimations for the real wind and snow loads and their combinations, structural analyses as well as detailed evaluations on the basis of previous investigations, literature and regulations were conducted. It was revealed that some of the examined components were manufactured from Thomas steel which was partially in embrittled condition. The investigated towers fulfilled the design codes valid at the time of erection. However the present line loads of the wet snow rolls on the conductors exceeded by far the ones given in the design codes valid at that time.
The load case leading to failure was reconstructed by the derived positions of loads mainly caused by unequal and asymmetric distribution of snow rolls on left and right electrical system. The loads and corresponding stresses acting on the structure before failure were estimated. By comparison with the fracture forces from mechanical testing of original members of the collapsed tower the component that primarily failed was localised. The primary fracture occurred on a diagonal member under tension made of Thomas steel which was weakened by embrittlement. The failure cause was a combination of heavy weather conditions (storm, approx. 0 °C and wet snowfall leading to heavy snow rolls on conductors), asymmetric loading conditions and the usage of Thomas steel which was partially embrittled. Finally, recommendations for avoiding future failures are given.