Filtern
Dokumenttyp
- Vortrag (7) (entfernen)
Referierte Publikation
- nein (7)
Schlagworte
- Synchrotron (3)
- Absorption edge (2)
- Tomography (2)
- Absorption edge tomography (1)
- Absorptionskante (1)
- Alloy (1)
- BAMline (1)
- Diesel Particulate Filter Materials (1)
- Legierung (1)
- MOF (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (7)
Microstructural changes in porous cordierite for diesel particulate filter applications caused by machining were characterized using microtensile testing and X-ray computed tomography (XCT). Young’s modulus was determined on ~215-380 m thick machined samples by digital image correlation. Results show a decrease of Young’s modulus due to machining of the thin samples. Explanation of this phenomenon was provided by XCT: the presence of debris due to machining and the variation of porosity due to removal of the outer layers were quantified and correlated with the introduction of further microcracking.
Absorption edge tomography is a method which exploits the sudden change of the attenuation coefficient, when the photon energy crosses the absorption edge of an element. The beamline BAM line at BESSY II, which is operated by the Federal Institute for Materials Research and Testing, can provide a monochromatized beam in a photon energy range from 5 keV up to 80 keV with a bandwidth of 2%. Together with the microtomography setup, this enables differential tomography sensitive to any element with N >= 24 (Cr) by using an appropriate K- or L-edge in this range. Here, a polymer filament embedding metal organic framework (MOF) was prepared and used for 3D printing. Absorption edge tomography at the copper K edge was employed to perform a non-destructive 3D characterization of the microstructure of the embedded MOF. Data fusion was then used to determine the size distribution of the embedded MOF.
Absorptionskantentomographie, auch bekannt als differentielle Tomographie an Kanten, ist ein Verfahren, bei dem ausgenutzt wird, dass sich die Schwächung von Röntgenstrahlen beim Übergang der Photonenenergie über die Absorptionskanten sprunghaft ändert. Die Verwendung von Synchrotronstrahlung ermöglicht die Anwendung der Absorptionskantentomographie für nahezu jedes Element, da sie eine intensive, durchstimmbare Strahlenquelle mit kleiner Bandbreite darstellt. Der Mikrotomographieaufbau der BAM am Elektronenspeicherring BESSY II eignet sich mit einem Energiebereich von 5 keV bis über 60 keV und einer Ortsauflösung besser als 0.5 µm zur differentiellen Tomographie an den K-Kanten der Elemente von Chrom bis zu den Lanthaniden, bei Einbeziehung der L-Kante bis zu Uran.
In dieser Arbeit wird die Absorptionskantentomographie ausgenutzt, um das Gefüge von Legierungen dreidimensional und nichtdestruktiv zu vermessen. Als Beispiel wird eine Legierung zwischen Magnesium, Yttrium und Zink analysiert, die sich gegenüber unlegiertem Magnesium durch größere Festigkeit und geringere Korrosionsanfälligkeit auszeichnet. Der Grund dafür liegt in der Bildung einer kristallographisch hochgeordneten Phase (long period stacking ordered - LPSO) der Legierungsbestandteile, die die Matrix in Form von Fasern durchzieht. Anhand ihres Yttriumgehaltes wird die dreidimensionale Verteilung der LPSO-Phase in der Matrix für verschiedene Proben bestimmt und mit Schnittbildern und Korrosionstests verglichen. Die Absorptionskantentomographie erweist sich als eine geeignete Methode, um die dreidimensionale Mikrostruktur von Legierungen zu charakterisieren.
Absorption edge tomography, also known as differential tomography at absorption edges, is a method which exploits the sudden change of the attenuation coefficient, when the photon energy crosses the absorption edge of an element. Synchrotron radiation is the best source for absorption edge tomography, because of its small bandwidth, high intensity and easily adjustable photon energy. The synchrotron beamline BAMline at the synchrotron radiation facility BESSY II in Berlin, which is operated by the Bundesanstalt für Materialforschung und -prüfung (BAM), provides a monochromatized beam in a photon energy range from 5 keV up to 80 keV with a bandwidth of 2%, when the double multilayer monochromator is used. Together with the microtomography setup, this enables differential tomography with submicron resolution at the K edge of the elements from chromium up to the lanthanides, and up to uranium, when the L edges are used as well.
In this work, metal organic frameworks (MOFs) embedded in polymer are characterized using differential tomography. MOFs are microporous structures of metal ions, coordinated by organic linker molecules, that can be used in a broad field of applications, especially in gas storage and catalysis. In this work, polymer embedded MOFs were extruded into filaments, which could be used for 3d-printing to profit from the specific properties of the MOFs in polymeric materials combined with the arbitrary shapes provided by 3d-printing. For the extrusion, different polymer classes like ABS, polyester- and polyetherurethanes, as well as different MOFs (ZIF-8, ZIF-67, HKUST-1) were used to create MOF containing filaments with a nominal diameter of 3.0 mm. Differential tomography at the edges of the Zn, Co, and Cu was then used to find the distribution of the corresponding MOF in the filament and to analyze the shape of the inclusions.
Absorption edge tomography, also known as differential tomography at absorption edges, is a method which exploits the sudden change of the attenuation coefficient, when the photon energy crosses the absorption edge of an element. Synchrotron radiation is the best source for absorption edge tomography, because of its small bandwidth, high intensity and easily adjustable photon energy. The synchrotron beamline BAMline at the synchrotron radiation facility BESSY II in Berlin, which is operated by the BundesanstaltfürMaterialforschung und -prüfung (BAM), provides a monochromatized beam in a photon energy range from 5 keV up to 80 keV with a bandwidth of 2%, when the double multilayer monochromator is used. Together with the microtomography setup, this enables differential tomography at the K edge of the elements from chromium up to the lanthanides, and up to uranium, when the L edges are used as well.
In this work, the absorption edge tomography is employed to perform a non-destructive, three-dimensional characterization of the microstructure of metallic alloys. As an example, a high strength Mg-Y-Zn alloy containing long period stacking ordered (LPSO) phases is analysed. The alloy with a nominal composition of Mg97Y2Zn1 was synthesized by melting highly pure magnesium, zinc and a Mg-22%Y master alloy and casting an ingot, which was homogenised at 350 °C and then extruded using an extrusion ratio of 18:1.
The results demonstrate that synchrotron based absorption edge tomography is a promising technique to perform a 3D characterization of the microstructure of metallic alloys.