Filtern
Dokumenttyp
- Vortrag (7)
- Beitrag zu einem Tagungsband (5)
- Posterpräsentation (3)
- Zeitschriftenartikel (2)
Referierte Publikation
- nein (17) (entfernen)
Schlagworte
- Synchrotron (5)
- Absorption edge (3)
- BAMline (3)
- Simulation (3)
- Tomography (3)
- Absorption edge tomography (2)
- Absorptionskante (2)
- Legierung (2)
- MOF (2)
- Probability of detection (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (7)
The computer simulation of radiography is applicable for different purposes in NDT such as for the qualification of NDT systems, the optimization of system parameters, feasibility analysis, model-based data interpretation, education and training of NDT/NDE personnel, and others. Within the framework of the European project PICASSO simulators will be adapted to support reliability assessments of NDT tasks. The radiographic simulator aRTist developed by BAM is well suited for this task. It combines analytical modelling of the RT inspection process with the CAD-orientated object description applicable to various industrial sectors such as power generation, aerospace, railways and others. The analytic model includes the description of the radiation source, the interaction of Radiation
with the material of the part, and the detection process with special focus to DIR. To support reliability estimations the simulation tool is completed by a tool for probability of detection (POD) estimation. It consists of a user interface for planning automatic simulation runs with varying parameters, specifically defect variations.
Further, an automatic image analysis procedure is included to evaluate the defect visibility and calculate the POD therefrom.
X-ray computed tomography (CT) is a volumetric (3D) Imaging diagnostic method, well established in the medical field, and in industrial NDE as well. Developments in industrial CT aim to extent the applicability to complex structures, which do not allow the access of all directions. This are e.g. limited view, data and angle CT applications. New reconstruction algorithms are required on one
side, and the accuracy has to be improved on the other side. Numerical Simulation can support such developments by providing well defined data sets for the testing of reconstruction algorithms. This approach of virtual CT is realized within the radiographic simulator aRTist, developed by BAM. The poster shows the possibilities of this tool to consider complex scan paths. Simulated data sets have been reconstructed by an versatile backprojection algorithm.
Computer simulation of radiography can be used for different purposes in NDT, such as qualification of NDT systems, optimization of radiographic parameters, feasibility analysis, model-based data interpretation, and training of NDT/NDE personnel. BAM has been working on modeling in the field of radiographic testing for many years. With the gathered theoretical background and the familiarity with practical requirements of industrial application the simulation software aRTist has been developed. This analytical simulator includes a description of the radiation source, the interaction of radiation with test pieces and flaws, and the detection process with special focus on film and digital industrial radiology. It features high processing speed with nearinteractive frame rates and a high level of realism. Here we focus on the recent developments of the simulator, notably the release of aRTist version 2. Extended functionality regarding automated virtual computed tomography now allows for arbitrary scan paths. Another program extension supports reliability investigations and provides a user interface for planning automatic simulations with varying parameters and defects.
Within the framework of the European project PICASSO, the radiographic simulator aRTist (analytical
Radiographic Testing inspection simulation tool) developed by BAM has been extended for reliability
assessment of film and digital radiography. A simulation supported probability of detection (POD) methodology
has been developed and the validity of the approach has been studied using an application from the aeronautics
industry. An experimental POD has been determined with the help of a specialized software tool, developed to
aid with the collection of large series of POD data. The resulting POD is compared to simulations of the same
setting using aRTist and the newly available module for simulation supported POD. A quantitative agreement
within a few percent is achieved between the experimental and the simulation supported POD.
Absorption edge tomography is a method which exploits the sudden change of the attenuation coefficient, when the photon energy crosses the absorption edge of an element. The beamline BAMline at BESSY II, which is operated by the Federal Institute for Materials Research and Testing, can provide a monochromatized beam in a photon energy range from 5 keV up to 80 keV with a bandwidth of 2%. Together with the microtomography setup, this enables differential tomography sensitive to any element with N >= 24 (Cr) by using an appropriate K- or L-edge in this range. Here, absorption edge tomography at the Yttrium edge is employed to perform a non-destructive 3D characterization of the microstructure of a high strength Mg-Y-Zn alloy. The long period stacking ordered (LPSO) phase which forms fibres in this material was extracted based on the Yttrium content and the fibre length distribution was analysed.
Microstructural changes in porous cordierite for diesel particulate filter applications caused by machining were characterized using microtensile testing and X-ray computed tomography (XCT). Young’s modulus was determined on ~215-380 m thick machined samples by digital image correlation. Results show a decrease of Young’s modulus due to machining of the thin samples. Explanation of this phenomenon was provided by XCT: the presence of debris due to machining and the variation of porosity due to removal of the outer layers were quantified and correlated with the introduction of further microcracking.
Ti-Al-Nb based intermetallic layers of sufficient quality and thickness were obtained by non-vacuum electron beam cladding on the surfaces of Ti workpieces. Optical microscopy and X-ray tomography did not reveal any dramatical defects in the structure of cladded layers. X-ray diffraction as well as scanning and transmission electron microscopy were applied to thoroughly investigate the structure and phase composition of coatings. It was found that non-equilibrium cooling conditions of coatings provided by fast removal of heat to untreated Ti substrate after the electron beam cladding was terminated induced the proceeding of metastable phase transformations. For example, γ-phase formation was suppressed in these coatings. In coatings with 8 and 20 at.% Nb (46 and 43% Al respectively) along with ordered with α2, formation of disordered solution of the alloying elements in α-Ti took place. In high-Nb alloys β(B2) phase has undergone the diffusionless transformation to ω’, which is the intermediate phase in β → ω and the coating with the maximum Nb content characterized by appearance of γ1 as a main phase. ω-phase had negative influence to hardness and wear resistance of coatings, however, generally this paremeter increased in 1.3–1.75 times compared to cp-Ti. The high temperature creep and oxidation properties decreased proportionally with increasing Nb and decreasing Al content in the cladded layers.
The quality of components made by laser beam melting (LBM) additive manufacturing is naturally influenced by the quality of the powder bed. A packing density <1 and porosity inside the powder particles lead to intrinsic voids in the powder bed. Since the packing density is determined by the particle size and shape distribution, the determination of these properties is of significant interest to assess the printing process. In this work, the size and shape distribution, the amount of the particle’s intrinsic porosity, as well as the packing density of micrometric powder used for LBM, have been investigated by means of synchrotron X-ray computed tomography (CT). Two different powder batches were investigated: Ti–6Al–4V produced by plasma atomization and stainless steel 316L produced by gas atomization. Plasma atomization particles were observed to be more spherical in terms of the mean anisotropy compared to particles produced by gas atomization. The two kinds of particles were comparable in size according to the equivalent diameter. The packing density was lower (i.e., the powder bed contained more voids in between particles) for the Ti–6Al–4V particles. The comparison of the tomographic results with laser diffraction, as another particle size measurement technique, proved to be in agreement.