Due to the great quantities of construction and demolition waste in Europe, the reuse of building material waste as secondary raw materials is of particular importance. A recycling of building materials can meet the requirements of sustainability in several aspects: the extended time availability of primary raw materials and the related protection of natural resources as well as the saving of landfill sites. In recent years sulphates originating from gypsum in secondary building materials, made of construction and demolition waste, received growing attention. Sulphates are unwanted in secondary building materials for concrete production as well as for other use e.g. in unbounded layers. The content of gypsum resp. sulphates in secondary aggregates can be reduced by different methods. Depending on the type of material different steps for selective dismantling can be used to separate gypsum containing residues from concrete rubble. Furthermore some steps for the processing of building rubble are suitable for the reduction of sulphates in the produced aggregates. An environmental evaluation of different ways for the production of recycled concrete aggregates was performed with regard to a reduction of sulphates in the secondary building material. The use of techniques for selective dismantling was environmentally advantegous for the deconstruction of three investigated model houses.
The plant-availability of phosphorus (P) in fertilizers and soil can strongly influence the yield of agricultural crops. However, there are no methods to efficiently and satisfactorily analyze the plant-availability of P in sewage sludge-based P fertilizers except by undertaking time-consuming and complex pot or field experiments. We employed the diffusive gradients in thin films (DGT) technique to quantify the plant P availability of various types of P fertilizers with a novel focus on sewage sludge-based P fertilizers. Mixtures of fertilizer and soil were incubated for 3 weeks at 60% water holding capacity. DGT devices were deployed at the beginning of the incubation and again after 1, 2, and 3 weeks. Two weeks of incubation were sufficient for the formation of plant-available P in the fertilizer/soil mixtures. In a pot experiment, the DGT technique predicted maize (Zea mays L.) biomass yield and P uptake significantly more accurately than standard chemical extraction tests for P fertilizers (e.g., water, citric acid, and neutral ammonium citrate). Therefore, the DGT technique can be recommended as a reliable and robust method to screen the performance of different types of sewage sludge-based P fertilizers for maize cultivation minimizing the need for time-consuming and costly pot or field experiments.
Along with the globally increasing energy demand the application of renewable energy sources is
urgently required. According to national regulations and international treaties (e.g. Kyoto Protocol)
these sources shall be sustainably available at reasonable financial effort and non-polluting during
production, use and waste treatment. Using photovoltaic sources (PV), these requirements can
clearly be met. All industry has to follow the best available technology and an integrative life cycle
approach for their products and production. PV thin film technology strictly responds to this obligation.
In order to save material resources and to minimise undesirable landfill recycling of spent PV
modules is necessary. Recycling of multi-component materials containing mixed metals typically
consists of three parts: liberation, separation, and recovery. In our study (RESOLVED an EU
Demonstration Project) the focus is on liberation and separation. The converting layer (CdTe) was
liberated (removed) from the glass carrier by sandblasting and separated subsequently from the
blast material (e.g. corundum) and other components using stepwise different separation techniques.
Both the glass substrate and CdTe are subject to re-use. The overall feasibility of the recycling
process is primarily governed by the efficiency of the procedure applied to the separation of CdTe
from the rest (blasting material, glass residues, etc.). This was performed by water-based flotation.
Several flotation procedures were studied regarding their separation yields. The distribution of
CdTe in the phases involved (flotate, water, residue) was measured using energy dispersive X-ray
fluorescence spectrometry (EDXRS) intended for future routine application and by instrumental
large-volume photon activation analysis (IPAA) as a reference procedure. The results of both analytical
methods were in satisfactory agreement.
Blast furnace (BF) sludge and electric arc furnace (EAF) dust are typical wastes that incur from iron and steel production. In addition to iron, calcium, carbon, and silicon they usually contain high concentrations of heavy metals such as zinc, lead, and cadmium that are potentially hazardous to the environment, rendering disposal in landfills ecologically problematic and costly. Consequently, pyrometallurgical, hydrometallurgical, and hybrid methods for selective elimination of non-ferrous heavy metals from BF sludge and EAF dust have been conceived, of which only the carbothermic reduction route taken in the so-called Waelz rotary kiln process has been proven to be economically successful. However, this process has several drawbacks regarding efficiency of heavy-metal removal and recovery of iron, and it does not allow processing of BF sludge. In this study, we investigated the efficiency and feasibility of selective chlorination and evaporation of non-ferrous heavy metals, particularly zinc and lead, in both BF sludge and EAF dust as an alternative, thermochemical processing route. To this end, hydrochloric acid and iron(II) chloride solution have been used as chlorinating agents, and the process of heavy-metal chlorination and evaporation has been investigated under inert operating conditions, at variable chlorine concentrations, and at temperatures between 500 and 1200 °C.
High zinc and lead removal efficiencies of > 99.5 % were achieved with both chlorinating agents, but iron(II) chloride turned out to be overall more efficient for removal of zinc and lead from BF sludge and EAF dust. Interestingly, and in contrast to previous studies, the iron was completely retained in the processed solid residue, therefore rendering the processed residues virtually zinc- and lead-free raw materials that may either be used internally (e.g., feeding processed BF sludge and EAF dust back into the respective furnaces) or externally (e.g., for cement production).