Filtern
Dokumenttyp
- Zeitschriftenartikel (11)
- Vortrag (3)
- Posterpräsentation (2)
- Sonstiges (1)
Schlagworte
- Mass Spectrometry (5)
- Hydrogen (4)
- ICP-MS (4)
- Instrumentation (4)
- Nanoparticles (3)
- Adsorption (2)
- Ammonia (2)
- Gas Chromatography (2)
- Humidity (2)
- Nano (2)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (17)
- 1.0 Abteilungsleitung und andere (17)
- 1.6 Anorganische Referenzmaterialien und Gasanalytik (3)
- 8 Zerstörungsfreie Prüfung (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 1.3 Instrumentelle Analytik (1)
- 1.8 Umweltanalytik (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (1)
- P Präsident (1)
Eingeladener Vortrag (wissenschaftliche Konferenzen)
- nein (3)
The low-temperature plasma (LTP) probe is a common plasma-based source used for ambient desorption–ionization mass spectrometry (MS). While the LTP probe has been characterized in detail with MS, relatively few studies have used optical spectroscopy. In this paper, two-dimensional (2D) imaging at selected wavelengths is used to visualize important species in the LTP plasma jet. First, 2D steady-state images of the LTP plume for N2+ (391.2 nm), He I (706.5 nm), and N2 (337.1 nm) emissions were recorded under selected plasma conditions. Second, time-resolved 2D emission maps of radiative species in the LTP plasma jet were recorded through the use of a 200 ns detection gate and varying gate delays with respect to the LTP trigger pulse. Emission from He I, N2+, and N2 in the plasma jet region was found to show a transient behavior (often referred to as plasma bullets) lasting only a few microseconds. The N2+ and He I maps were highly correlated in spatial and temporal structure. Further, emission from N2 showed two maxima in time, one before and one after the maximum emission for N2+ and He I, due to an initial electronic excitation wave and ion–electron recombination, respectively. Third, the interaction of the LTP probe with a sample substrate and an electrically grounded metallic needle was studied. Emission from a fluorophore on the sample substrate showed an initial photon-induced excitation from plasma-generated photons followed by electronic excitation by other plasma species. The presence of a grounded needle near the plasma jet significantly extended the plasma jet lifetime and also generated a long-lived corona discharge on the needle. The effect of LTP operating parameters on emission spectra was correlated with mass-spectral results including reagent-ion signals. Lastly, five movies provide a side-by-side comparison of the temporal behavior of emitting species and insights into the interactions of the emission clouds with a sample surface as well as an external needle. Temporally and spatially resolved imaging provided insights into important processes in the LTP plasma jet, which will help improve analyte ion sampling in LTP–MS.
Mehrdimensionale Trenntechniken sowie Kopplungstechniken verbessern weiter die Auflösung in der Analytik. In der Elementanalytik beeindrucken neue Entwicklungen der Massenspektrometrie mit induktiv gekoppeltem Plasma, in der Archäometrie zerstörungsfreie In‐situ‐Analysen. Der 3‐D‐Druck treibt die elektroanalytische Forschung voran, und die Prozessanalytik setzt auf Lab‐on‐a‐Chip und vermeldet Neues bei der Raman‐Spektroskopie mit Flüssigkernlichtleitern.
In this proof-of-principle study, we present our contribution to single particle inductively coupled plasma mass spectrometry (spICP-MS) developments with a novel in-house built data acquisition system with nanosecond time resolution (nanoDAQ) and a matching data processing approach. The new system can continuously sample the secondary electron multiplier (SEM) detector signal and enables the detection of gold nanoparticles (AuNP) as small as 7.5 nm with the commercial single quadrupole ICP-MS instrument used in this study. Recording of the SEM signal by the nanoDAQ is performed with a dwell time of approximately 4 ns. A tailored method was developed to process this type of transient data, which is based on determining the temporal distance between detector events that is denoted as event gap (EG). We found that the inverse logarithm of EG is proportional to the particle size and that the number of detector events corresponding to a particle signal distribution can be used to calibrate and determine the particle number concentration (PNC) of a nanoparticle dispersion. Due to the high data acquisition frequency, a statistically significant number of data points can be obtained in 60 s or less and the main time limitation for analyses is merely the sample uptake time and rinsing step between analyte solutions. At this stage, the data processing method provides average information on complete data sets only and will be adapted to enable particle-by-particle analysis with future hardware/software revision.
In this investigation, we present a direct method employing UV-light radiation to induce point defects, specifically Ti3+ and VO, onto the surface of TiO2 nanosheets (TiO2-NSs) and efficiently decorate them with Pt particles. The addition of the Pt precursor is carried out during rest periods following UV-light cessation (light-induced samples, LI) and during UV-light exposure (photo-deposited samples, PD). The size and distribution of Pt particles on both LI and PD TiO2-NSs are systematically correlated with varying resting times, enabling precise control over Pt loading. The characterization of various TiO2-NSs is extensively conducted using microscopy techniques (FESEM, TEM, and HAADF-STEM) and spectroscopy (XPS). Gas chromatography is also employed for the evaluation of the H2 photocatalytic performance of various samples. Our findings reveal that Pt particles deposit on the TiO2-NSs surfaces as nanoparticles under illumination. After a 5 minutes resting time, a combination of Pt single atoms (SAs) and clusters, with a maximum loading of 0.37 at%, is formed. Extending the resting time to 60 minutes results in a gradual reduction in Pt SAs and clusters, leading to the deposition of Pt nanoparticles with lower loadings. Notably, Pt SAs and clusters exhibit superior performance in hydrogen evolution, showcasing a remarkable 4000-fold increase over pristine TiO2-NSs. Additionally, sustained UV radiation during Pt addition in the photo-deposited samples results in the formation of Pt nanoparticles with lower loading compared to LI samples, consequently diminishing photocatalytic hydrogen production. This study not only provides insights into the controlled manipulation of Pt SAs on TiO2-NSs but also highlights their exceptional efficacy in hydrogen evolution, offering valuable contributions to the design of efficient photocatalytic systems for sustainable hydrogen generation.
Volatile organic compounds (VOCs) play an important role in the defense against pest infestations on plants. The analysis of these VOCs using gas chromatography mass spectrometry (GC-MS) enables the detection of pests by analyzing the VOC composition (VOC profiles) for specific patterns and markers. The analysis of such complex datasets with high biovariability poses a particular challenge. For this reason, a multivariate evaluation method based on a self-written Python script, using principal component analysis (PCA) and linear discriminant analysis (LDA), was developed and tested for functionality using a dataset, which has been evaluated manually and has identified five specific markers (2,4-dimethyl-1-heptene, 3-carene, alpha-longipinene, cyclosativene, and copaene) for Anoplophora glabripennis (ALB) infestation on Acer trees. The results obtained in the present study did not only match the manually evaluated results, but lead to further insight into the dataset. Another sesquiterpene which is assumed to be alpha-zingiberene was identified as an ALB specific marker in addition to 2,4-dimethyl-1-heptene and 3-carene. Furthermore, the European native beetle species goat moth Cossus cossus (CC) and poplar long-horned beetle Saperda carcharias (SC) were also analyzed for their VOCs to differentiate ALB specific VOC from other pest infestations. This comparison lead to the conclusion that the compounds alpha-longipinene, cyclosativene, and copaene are not specific for ALB but for pest infestation in general. It was possible to identify not only specifically produced VOCs, but also differences in concentrations that arise specifically during ALB infestation. Therefore, the evaluation method for the detection of plant pests presented in this study represents a time-saving alternative to conventional non computing methods, which in addition provides more detailed results.
The analysis of herbivore-induced plant volatiles (HIPVs) is essential for understanding plant-environment interactions and defense strategies against herbivores. Proton transfer reaction time-of-flight mass spectrometry (PTR–TOF–MS) is a powerful analytical tool that enables real-time monitoring and quantification of diverse groups of HIPVs. However, the PTR–TOF–MS technique is constrained in its ability to effectively differentiate between isomers. When analyzing complex mixtures of HIPVs, the separation of isomers becomes crucial as major compound classes such as terpenes comprise thousands of isomers. In this study, we present an optimized fast gas chromatography (fastGC) based on a modified version of the commercially available fastGC add-on integrated into a mobile PTR–TOF. The system was optimized for the analysis of emissions from enclosed trunks of Acer platanoides infested by Anoplophora glabripennis (Motschulsky), commonly known as Asian longhorned beetle (ALB). The development of fastGC was primarily focused on the sesquiterpenes α-longipinene, cyclosativene and α-copaene, which serve as strong indicators of ALB infestation. These sesquiterpenes were separated in less than three minutes, with intra-day retention time RSD < 0.6 % and resolutions of 2.6 ± 0.3 and 1.3 ± 0.2. In comparison to the original system, the optimized fastGC demonstrates more than tripled sesquiterpene resolution, twice the sensitivity relative to direct inlet mode, and an approximately 10 % reduction in total analysis time. The optimized fastGC–PTR–TOF allows for near real-time analysis of complex mixtures of biogenic VOCs, making it a powerful tool for environmental monitoring, integrated pest management, and forest protection.
Diamond electrochemistry is primarily influenced by quantities of sp3‐carbon, surface terminations, and crystalline structure. In this work, a new dimension is introduced by investigating the effect of using substrate‐interlayers for diamond growth. Boron and nitrogen co‐doped nanocrystalline diamond (BNDD) films are grown on Si substrate without and with Ti and Ta as interlayers, named BNDD/Si, BNDD/Ti/Si, and BNDD/Ta/Ti/Si, respectively. After detailed characterization using microscopies, spectroscopies, electrochemical techniques, and density functional theory simulations, the relationship of composition, interfacial structure, charge transport, and electrochemical properties of the interface between diamond and metal is investigated. The BNDD/Ta/Ti/Si electrodes exhibit faster electron transfer processes than the other two diamond electrodes. The interlayer thus determines the intrinsic activity and reaction kinetics. The reduction in their barrier widths can be attributed to the formation of TaC, which facilitates carrier tunneling, and simultaneously increases the concentration of electrically active defects. As a case study, the BNDD/Ta/Ti/Si electrode is further employed to assemble a redox‐electrolyte‐based supercapacitor device with enhanced performance. In summary, the study not only sheds light on the intricate relationship between interlayer composition, charge transfer, and electrochemical performance but also demonstrates the potential of tailored interlayer design to unlock new capabilities in diamond‐based electrochemical devices.
In this presentation, recent developments in inductively coupled plasma mass spectrometry (ICP-MS) instrumentation for particle characterization in complex mixtures will be reviewed. The current state-of-the-art in single-particle (sp) ICP-MS instrumentation for the detection and characterization of nanoparticles (NP) and microplastics (MPs) as well as remaining challenges will be discussed.
While millisecond dwell times were used in the advent of spICP-MS, the use of microsecond dwell times helped to improve nanoparticle data quality and particle size detection limits. We could show that a custom-built high-speed data acquisition unit with microsecond time resolution (μsDAQ) can be used to successfully address issues of split-particle events and particle coincidence, to study the temporal profile of individual ion clouds, and to extend the linear dynamic range by compensating for dead time related count losses.
Our latest development is an in-house built data acquisition system with nanosecond time resolution (nanoDAQ). Recording of the SEM signal by the nanoDAQ is performed on the nanosecond time scale with a dwell time of approximately 2 ns and enables detection of gold nanoparticles (AuNP) as small as 7.5 nm with a commercial single quadrupole ICP-MS instrument. [1] Analysis of acquired transient data is based on the temporal distance between detector events and a derived ion event density. It was shown that the inverse logarithm of the distance between detector events is proportional to particle size. Also, the number of detector events per particle can be used to calibrate and determine the particle number concentration (PNC) of a nanoparticle dispersion. In addition to inorganic nanoparticles, first results on the detection of microplastics with spICP-MS will be discussed.
In this presentation, recent advances in plasma spectrochemistry with hot and cold plasma sources for the direct detection of nanoparticles as well as per- and polyfluoroalkyl substances (PFAS) will be discussed. In the first part, single-particle inductively coupled plasma mass spectrometry (spICP-MS) with an in-house built data acquisition system with nanosecond time resolution (nanoDAQ) will be presented. In the second part, we turn to a cooler plasma source. Specifically, a flowing atmospheric-pressure afterglow source (FAPA) and its application for the direct mass spectrometric analysis of PFAS will be discussed.