This work focuses on the design and fabrication of low-cost and fast-response of an electronic nose (E-nose) based on semiconductor gas sensors, for discriminating some synthetic gases such as ammonia (NH3), ethanol (C2H5OH), and hydrogen sulfide (H2S). Additionally, the capability of separating different concentration levels of each considered gases was checked. Dataset treatment of E-nose by using Principal Component Analysis (PCA) showed a good discrimination of the different synthetic gases. Furthermore, perfect classification was reached of different concentration levels of the analysed gases by using Discriminant Function Analysis (DFA). In the light of these results, it could be stated that the developed E-nose system constitutes an inexpensive, rapid, simple to use, and efficient tool for synthetic gases detection.
Ein Umlaufkühler ist im Betrieb explodiert. Splitter des zerborstenen Gehäuses aus Kunststoff wurden mit dem Kühlwasser in die Umgebung geschleudert, am Betriebsort entstand Personenschaden. Bei Funktionsprüfungen am beschädigten Gerät traten unerwartet - aber reproduzierbar - Knalleffekte bei Berührung der Außenoberfläche der Kupfer-Kühlschlange auf. Ein möglicher Mechanismus konnte im Labor durch Synthese von Kupferazid auf Kupferproben und Auslösung vergleichbarer Knalleffekte nachgestellt werden. Damit ist die Plausibilität des beschriebenen Schadensereignisses mit diesem oder einem ähnlich reagierenden Stoff belegt. Ein eindeutiger Nachweis darüber, dass bei dem aufgetretenen Schadensfall dieselbe chemische Reaktion stattgefunden hat, war nicht möglich, da die Belag-Überreste aus dem explodierten Kühlgerät für eine Analyse nicht mehr in ausreichender Menge verfügbar gewesen sind.
Monitoring of repositories for radioactive waste requires techniques which can be applied long-term under harsh conditions. In this work, the reliability and suitability of materials and a capacitive sensor for measuring relative humidity are investigated, which are to be embedded in the special concrete components for the closure structures of underground repository. Preliminary tests with accelerated aging of the materials used, validation of the sensors under difficult conditions, investigations of the surfaces after aging by pH 14 solution, defined exposure of the sensors in a climatic chamber and the microscope images are discussed. The results will be used for further development and optimization of the RFID based sensor systems which can be applied to monitor the condition of different building structures without cabling.
In this study, the ability of an electronic nose developed to analyze and monitor odor emissions from three poultry farms located in Meknes (Morocco) and Berlin (Germany) was evaluated. Indeed, the potentiality of the electronic nose (e-nose) to differentiate the concentration fractions of hydrogen sulfide, ammonia, and ethanol was investigated. Furthermore, the impact change of relative humidity values (from 15% to 67%) on the responses of the gas sensors was reported and revealed that the effect remained less than 0.6%. Furthermore, the relevant results confirmed that the developed e-nose system was able to perfectly classify and monitor the odorous air of poultry farms.
In this work, we demonstrate the ability of an electronic nose system based on an array of six-semiconductor gas sensors for outdoor air quality monitoring over a day at a traffic road in downtown of Meknes city (Morocco). The response of the sensor array reaches its maximum in the evening of the investigated day which may due to high vehicular traffic or/and human habits resulting in elevated concentrations of pollutants. Dataset treatment by Principal Component Analysis and Discriminant Function Analysis shows a good discrimination between samples collected at different times of the day. Moreover, Support Vector Machines were used and reached a classification success rate of 97.5 %. Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS) technique was used to validate the developed e-nose system by identifying the composition of the analyzed air samples. The discrimination obtained by e-nose system was in good agreement with the TD-GC-MS results. This study demonstrates the usefulness of TD-GC-MS and e-nose, providing high accuracy in discriminating outdoor air samples collected at different times. This demonstrates the potential of using the e-nose as a rapid, easy to use and inexpensive environmental monitoring system.
Sensor systems are widely used in hydrogen technologies. The lecture presents requirements and properties of sensor systems and shows application examples of these technologies for safety and process control for hydrogen technologies. The focus is on gas sensors as well as sensors for pressure, temperature and gas flow. These systems are applied, among other things, for monitoring and control of operating conditions, indication of hazardous conditions and triggering of alarms.
The determination of the measurement uncertainty of quantitative and qualitative results is an important quality management tool, for example to describe measuring equipment, procedures, measurement results and the quality of products. The lecture presents the process description for the determination of the measurement uncertainty according to GUM, the determination of uncertainties in qualitative measurement results and the application of the measurement uncertainty for conformity assessment.
Introduction of H2Safety@BAM
(2021)
This contribution for the Open Forum of the 8th HSN Symposium introduces the SensRef activities of the Competence Centre H2Safety@BAM.
The evaluation of measurement uncertainty is essential for testing and calibration laboratories. This paper provides a general process description for the determination of the measurement uncertainty of quantitative data and its application to the conformity assessment with examples, and how to deal with the uncertainty of qualitative (Boolean) results, e. g. when "Alarm" or "No alarm" occours in an instrument display.
The internal project "SealWasteSafe" of the Federal Institute for Materials Research and Testing is dedicated to the further improvement in the construction of sealing systems for underground repositories of radioactive waste. Particularly, a multi-sensory concept is developed to ensure quality assurance and continuous long-term monitoring on the engineered barriers. Therefore, beside other measures, the temperature and equilibrium moisture of the construction shall be monitored and respective multi-sensoric monitoring concepts are tested first on the laboratory scale. One focus in this project is on embedded application in alkali-activated mortars (AAM), which results in special requirements for the resistance of the sensors to strongly alkaline environments with up to pH 14. In addition, the ingress of water along cables or at sensor positions is critical for sensors embedded in concrete, as the cable access of the sensor housing is a major weak point. It is therefore advisable to equip wireless high frequent radio frequency identification-based sensors, so called HF RFID sensors (short: RFID), that do not require cable access and thus have a stable and leak-proof sensor housing for long-term monitoring. In this contribution, the results from temperature, moisture and transmitted power monitoring of a AAM and a M2 specimens by means of HF RFID sensor systems are presented.