Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (21) (entfernen)
Schlagworte
- Electronic nose (6)
- Voltammetric electronic tongue (4)
- ANOVA (2)
- Adulteration detection (2)
- Cumin discrimination (2)
- Gas chromatography (2)
- Gassensor (2)
- Geographical origins (2)
- Ion mobility spectrometry (2)
- Measurement uncertainty (2)
Organisationseinheit der BAM
Traces of microbial volatile organic compounds (MVOCs) in air can indicate the presence of growth of moulds in the indoor environment. Ion-mobility spectrometry is a very promising method for detection of these MVOCs, because of its high sensitivity. For development of an in-situ method for detection of MVOCs, a portable ion-mobility spectrometer (IMS) was used and test gases of 14 MVOCs and their respective mixtures were investigated. IMS spectra were recorded as a function of concentration of MVOCs in air. Drift time and mobility of reactant ions formed in positive polarity mode were determined and correlated with the mass-to-charge ratio (m/z) of the MVOCs investigated. The estimated detection limit has a specific value for each MVOC and is in the range 3 to 96 µg m-3 (1 to 52 ppbV). Indoor trials show that IMS can indicate hidden mould growth.
The metabolism of moulds results in the formation of various microbial volatile organic compounds (MVOCs). These substances can be used as an indicator for the presence of moulds in the indoor environment. Three different mould strains were cultivated on culture media and IMS spectra of gaseous mould metabolites were recorded using a portable mini system with a tritium source and a 5 cm drift cell. The headspace spectra are characteristic for mould species and their age. Typical gaseous components of the metabolites were identified and compared with results obtained from gas chromatography using a mass spectrometer detector. It was observed that the MVOCs formation depends on mould species and their growing stage with a maximum of MVOCs emission occurring during the first 10 days. These preliminary results show that IMS can be applied to detect MVOCs in indoor environment and indicate hidden mould growth.
The detection of the aroma and flavour volatile compounds of spices is key in product quality control. Accordingly, it is necessary to develop new electronic sensing systems for food adulteration control and authenticity assessment for protecting customer's health.
In this work, the capability of the E-nose and VE-tongue in combination with SPME-GC-MS to correctly discriminate between several cumin samples of different geographical origins and to detect their adulteration, by using unsupervised and supervised chemometric tools, was evaluated. Regarding the aroma profile, eleven volatile compounds were characterized by SPME-GC-MS; all of them were found in cumin powder while only eight are found in cumin seeds. The main volatile compounds detected were b-pinene, m-cymene, g-terpinene, cuminaldehyde and cuminic alcohol, in different proportions depending on the cumin sample form (seed or powder). In summary, the results obtained are sufficiently encouraging as a starting point for the development of new electronic sensing systems with more improvement in the reliability of the sensor's performance as well as chemometric tools in order to deal with a complex dataset.
A metrological approach to improve accuracy and reliability of ammonia measurements in ambient air
(2016)
The environmental impacts of ammonia (NH3) in ambient air have become more evident in the recent decades, leading to intensifying research in this field. A number of novel analytical techniques and monitoring instruments have been developed, and the quality and availability of reference gas mixtures used for the calibration of measuring instruments has also increased significantly. However, recent inter-comparison measurements show significant discrepancies, indicating that the majority of the newly developed devices and reference materials require further thorough validation. There is a clear need for more intensive metrological research focusing on quality assurance, intercomparability and validations. MetNH3 (Metrology for ammonia in ambient air) is a three-year project within the framework of the European Metrology Research Programme (EMRP), which aims to bring metrological traceability to ambient ammonia measurements in the 0.5–500 nmol mol−1 amount fraction range. This is addressed by working in three areas: (1) improving accuracy and stability of static and dynamic reference gas mixtures, (2) developing an optical transfer standard and (3) establishing the link between high-accuracy metrological standards and field measurements. In this article we describe the concept, aims and first results of the project.
The fluorescence properties of three molecular rotors, related to 4-dimethylamino-4-nitrostilbene (4-DNS), are studied versus different diesel/kerosene blends. In nonviscous solvents, these compounds can populate a twisted intramolecular charge transfer state which deactivates nonradiatively, successfully suppressing fluorescence emission. Solution experiments with diesel/kerosene blends showed a good linear correlation between the fluorescence intensity of the probe molecules and the diesel fraction of the blend. The dyes have been immobilized on paper, retaining their fluorescence behavior, i.e., negligible emission in the presence of nonviscous organic solvents and increasing fluorescence when the environment is increasingly viscous. When the impregnated paper is devised as a test strip, the latter is compatible with a newly designed smartphone reader system, which allows in-the-field measurements. The method can safely detect the presence of kerosene in diesel at ≥7%, which competes favorably with current standard methods for the detection of diesel adulteration.
Especially trace amounts of water vapour in gases can be reliably determined by coulometric trace humidity sensors. The principle of these sensors is based on water vapour absorption in a hygroscopic layer and its subsequent electrolytic decomposition. The calibration of sensors was performed in the humidity range, expressed as frost point temperature, from −30°C to −80°C . This range is equivalent to volume fractions smaller than 376 µL·L−1. Generated humidity was measured with coulometric sensors and a chilled dew point hygrometer that was used as reference. An empirical non-linear function was found between sensor signal and measured reference humidity. This function consists of two parameters with a measurement uncertainty. Both calibration parameters were checked by means of one-way analysis of variance. It showed that gas specific function can be used for humidity measurement in nitrogen, hydrogen, dinitrogen monoxide, compressed and synthetic air. It is possible to determine trace humidity in all tested gases with an expanded uncertainty less than 2.1 K (coverage factor k=2 ) regarding frost point temperature.
Trace humidity was measured by using miniaturized planar coulometric sensors in technical gases such as hydrogen, nitrogen, helium, nitrous oxide, and synthetic air. Frost point temperatures tf in the gases ranged from −60 °C to −30 °C, which is equivalent to a vapour mole fraction xv from 10 μmol mol−1 to 376 μmol mol−1. In addition, the generated humidity was determined by using a precision dew point hygrometer as reference. Nonlinear calibration functions were calculated that correlated electric current (sensor signal) and reference humidity. Parameters of functions were tested with one-way analysis of variances (ANOVA) to prove if all used sensors had a similar behavior in the same gas during experiments. Results of ANOVA confirmed that averaged functions can be applied for trace humidity measurement in nitrogen, helium, nitrous oxide, and synthetic air. The calculated functions were negligibly different for nitrogen, helium, and synthetic air. In humidified nitrous oxide, a minor change of parameters was observed due to lower electrical currents. In total contrast to that, the measured sensor signals were significantly higher in humidified hydrogen and each sensor required its own calibration function. The reason was a recombination effect that favoured multiple measurements of water molecules. Nevertheless, it was possible to measure continuously trace humidity in all tested gases by using coulometric sensors with an expanded uncertainty below 2 K (k = 2).
The Stolt Rotterdam tanker ship, filled with nitric acid, was unloading at the Krefeld-Uerdingen terminal on the Rhine River in November 2001. Nitric acid ran out of the stainless steel tanks into the ship's hull and damaged the structural steel. The ship then caught fire and sank at the terminal. Large quantities of nitrogen oxides were emitted, which drifted towards a residential area. Additionally, a mixture of acid and water was introduced into the Rhine River. The area became hazardous to people and the natural environment; however, the imminent danger for the residents and the environment was reduced because of the protective measures against pollution and the good teamwork between local authorities, fire brigades and the Bayer AG company. The acid was drained off of the ship using a controlled discharge of the acid into the river. Through the use of this measure, the ship was salvaged, limiting the pollution to the area and removing the health hazards to the people and the environment. After the ship was salvaged, the river police, along with assistance from the BAM Federal Institute for Materials Research and Testing, impounded the ship and selected corroded parts for further examination. Some of these components have been examined in detail by the BAM. These material investigations contributed to the elucidation of the origin of the leak in the floor panel. The cause of damage was deemed to be a result of a construction flaw at the enamelled valve on the load and discharge pipes.
The results from the comparative corrosion testing using the original structural steel and 60% acid revealed that the valves began to leak at least 8 h prior to the incident at the terminal.
Different electronic sensor systems coupled with multivariate data analysis were applied to characterize and classify seven saffron samples and to verify their declared geographical origin. The proposed electronic sensing consists of a low-cost electronic nose (E-nose) based on metal oxide semiconductor sensors and a voltammetric electronic tongue (VE-tongue) based on voltammetric sensors. The ability of multivariable analysis methods such as Principal Component Analysis (PCA), Hierarchical Cluster Analysis (HCA) and Support Vector Machines (SVMs) to classify the saffron samples according to their geographical origin have been investigated. Both PCA and HCA have shown an overlapping of E-nose responses. Moreover, the SVM analysis of the E-nose database reached a 66.07% success rate in the recognition of the saffron sample odour. On the other hand, good discrimination has been reached using PCA and HCA in the VE-tongue characterization case, besides a 100% accuracy in the saffron flavour recognition was attained. To validate the proposed electronic sensing systems, analytical chemical methods such as SPME-GC-MS and UV-Vis spectrophotometry were used. These analytical methods could be helpful tools to identify the composition of volatile compounds of the analysed saffron samples. Moreover, UV-Vis spectrophotometry was also used to determine the non-volatile profile of the samples from different geographic origins. It is demonstrated that the electronic sensing systems' findings are in a satisfactory correlation with the analytical methods. In the light of these results, we might say that the electronic systems offer a fast, simple and efficient tool to recognize the declared geographical origin of the saffron samples.