The development of fluorescence applications in the life and material sciences has proceeded largely without sufficient concern for the measurement uncertainties related to the characterization of fluorescence instruments. In this first part of a two-part series on the state-of-the-art comparability of corrected emission spectra, four National Metrology Institutes active in high-precision steady-state fluorometry performed a first comparison of fluorescence measurement capabilities by evaluating physical transfer standard (PTS)-based and reference material (RM)-based calibration methods. To identify achievable comparability and sources of error in instrument calibration, the emission spectra of three test dyes in the wavelength region from 300 to 770 nm were corrected and compared using both calibration methods. The results, obtained for typical spectrofluorometric (0°/90° transmitting) and colorimetric (45°/0° front-face) measurement geometries, demonstrated a comparability of corrected emission spectra within a relative standard uncertainty of 4.2% for PTS- and 2.4% for RM-based spectral correction when measurements and calibrations were performed under identical conditions. Moreover, the emission spectra of RMs F001 to F005, certified by BAM, Federal Institute for Materials Research and Testing, were confirmed. These RMs were subsequently used for the assessment of the comparability of RM-based corrected emission spectra of field laboratories using common commercial spectrofluorometers and routine measurement conditions in part 2 of this series (subsequent paper in this issue).
Glass-ceramics containing Ca2KNa(PO4)2 as the main crystalline phase have a solubility which is 8 times higher than that of alpha-tricalcium phosphate ceramics. When using these compositions in drug delivery systems, especially in bone, it is necessary to create a material with a high open porosity. A Ca2KNa(PO4)2-based glass-ceramic was prepared from a borosilicate glass melt. The processed material includes minor amounts of boron which are low enough for medical application. Tissue response was studied using an animal model. Particles were implanted in rabbit femurs. Bone and soft tissue development occurred at the particle interfaces. In general, most particles were enclosed in the network of trabecular bone. The advantages of using a biomaterial with high porosity (pore size of 1-3 micron), together with rapid biodegradation, bioactivity and biocompatibility, despite traces of boron, were shown. 4 refs.
In vivo test of a high porous rapidly resorbable dicalcium potassium sodium phosphate glass-ceramics
(2002)
Bone development and bone structure depend on surface roughness and structure of metalic implants
(2000)
In the second part of this two-part series on the state-of-the-art comparability of corrected emission spectra, we have extended this assessment to the broader community of fluorescence spectroscopists by involving 12 field laboratories that were randomly selected on the basis of their fluorescence measuring equipment. These laboratories performed a reference material (RM)-based fluorometer calibration with commercially available spectral fluorescence standards following a standard operating procedure that involved routine measurement conditions and the data evaluation software LINKCORR developed and provided by the Federal Institute for Materials Research and Testing (BAM). This instrument-specific emission correction curve was subsequently used for the determination of the corrected emission spectra of three test dyes, X, QS, and Y, revealing an average accuracy of 6.8% for the corrected emission spectra. This compares well with the relative standard uncertainties of 4.2% for physical standard-based spectral corrections demonstrated in the first part of this study (previous paper in this issue) involving an international group of four expert laboratories. The excellent comparability of the measurements of the field laboratories also demonstrates the effectiveness of RM-based correction procedures.
Composition and microstructure stability of cement compound under cyclic hydrothermal condition
(2020)
There have been many researches focused on the performance improvement of ultra-high performance concrete (UHPC) by autoclaving treatment. The goal of autoclaving is to increase the pozzolanic reaction, and to densify the cement stone and the transition zone which originates from the incorporation of supplementary cementitious materials (SCMs), such as silica fume, fly ash and blast furnace slag. Due to the superior properties, UHPC can also be utilized under high mechanical load and aggressive condition, for example, the fabrication of water tanks for thermal storage which is of great significance for saving energy and reducing CO2 emission. It is known that mineral stability of the hydration products of an inorganic binder is highly related to the temperature and pressure of the environment. A certain stable composition at room temperature, however, may undergo a phase transformation at high temperature and the performance decrease under this severe condition will generally be more severe. In this way, the rationale behind this deterioration under long-term hydrothermal condition involving many cycles and long duration has to be clarified, and then appropriate optimizing methods will be performed in order to obtain a kind of construction with high durability under aggressive environment. For this purpose, different types and amounts of SCMs are introduced into the standard mixture of UHPC and the phase compositions after autoclaving at 200 °C and 15.5 bar are determined by combined X-ray diffraction and scanning electron microscope. Mercury intrusion porosimeter is used to characterise the microstructure of the samples. In order to establish the relationship between microstructure and macroscopic properties, compressive and flexural strength are also investigated.
AbstraktDer 11. September 2024 wird nicht nur der Brückenbaucommunity in Deutschland in Erinnerung bleiben. Der Teileinsturz einer Spannbetonbrücke ohne Vorankündigung schlug berechtigterweise gesamtgesellschaftlich hohe Wellen. Betroffen war die Dresdner Carolabrücke – ein ästhetisches und ausgesprochen schlankes Bauwerk, welches in der Fachwelt zurecht als eine Ikone der Ingenieurbaukunst ihrer Zeit angesehen wird. Die Konstruktion sowie der Bau wären auch unter den heutigen Möglichkeiten eine Herausforderung. Der vorliegende Teil 1 des Beitrags fasst die Entstehungsgeschichte, die Konstruktion selbst und den Bau der Brücke zusammen. Es werden die Maßnahmen zur Instandhaltung und Sanierung der Brücke vorgestellt. In einem Teil 2 wird der Versuch der Rekonstruktion des Einsturzvorgangs unternommen und die Suche nach der Einsturzursache beschrieben. Zudem wird auf das aktuelle Monitoring eingegangen und ein Ausblick auf das mögliche weitere Vorgehen gegeben.
Large-scale nanoimprinted metasurfaces based on silicon photonic crystal slabs were produced and coated with a NaYF4:Yb3+/Er3+ upconversion nanoparticle (UCNP) layer. UCNPs on these metasurfaces yield a more than 500-fold enhanced upconversion emission compared to UCNPs on planar surfaces. It is also demonstrated how the optical response of the UCNPs can be used to estimate the local field energy in the coating layer. Optical simulations using the finite element method validate the experimental results and the calculated spatial three-dimensional field Energy distribution helps us to understand the emission enhancement mechanism of the UCNPs closely attached to the metasurface. In addition, we analyzed the spectral shifts of the resonances for uncoated and coated metasurfaces and metasurfaces submerged in water to enable a prediction of the optimum layer thicknesses for different excitation wavelengths, paving the way to applications such as electromagnetic field sensors or bioassays.