Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (27) (entfernen)
Schlagworte
- Wärmebehandlung (4)
- EPR (3)
- Korrosion (3)
- Nichtrostender Stahl (3)
- ThermoCalc (3)
- Bauprodukte (2)
- Corrosion resistance (2)
- Cultural heritage (2)
- Earth masonry (2)
- KorroPad (2)
Organisationseinheit der BAM
Bioresorbable carriers for subchondral anchoring of tissue-engineered cartilage in articular defects
(2000)
The Micro Structure of Traditional Brazilian Lime Plasters - The Custom House of Florianopolis
(2005)
Structural performances of earthen building materials. A comparison between different typologies
(2011)
Traditional construction techniques utilizing earthen materials are often seen as inferior compared to modern ways of building. Structural earthen elements are perceived as vulnerable towards environmental influences (moisture, frost) and in particular towards the load scenarios during earthquakes. In comparison to the recent advances in research on stone and brick masonry, knowledge on the structural performance of earthen building construction is limited and scattered. Consequently the confidence in the performance of these earthen buildings constructed in the traditional techniques during earthquakes is fairly low. The research presented here aims to make a comparison of mechanical behavior between different earth masonry material typologies, consisting of earth block masonry, rammed earth and cob. The paper has been developed in the framework of a larger research program called NIKER. BAM and other seventeen research partners from the Mediterrean area are jointly involved to develop and validate innovative materials and technologies for the systemic improvement of the seismic behavior of Cultural Heritage assets
The paper has been developed in the framework of a larger EC‐research program called NIKER, in which BAM and other seventeen research partners from the Mediterrean area are jointly involved. It aims to develop and validate innovative materials and technologies for the systemic improvement of the seismic behavior of Cultural Heritage assets. The death tolls brought about by recent catastrophes in
developing countries where many inhabitants lived in earthen dwellings (Gujarat, India 2001, Bam, Iran 2003 and Concepción, Chile 2010 Earthquakes, Tamil Nadu 2004 Tsunami) have brought about research studies aimed at improving earth construction in terms of strength, seismic resistance and speed of construction.
In comparison to the recent advances in research on stone and brick masonry, knowledge on the material properties and failure mechanisms of earthen Building construction is limited and scattered.
The research presented here by aims making a comparison of mechanical behaviour between different earth masonry material typologies, consisting of earth block masonry, rammed earth and cob.
Today, building is a complicated commercial process characterised by legalised agreements between all participants. For commercial building projects, all materials and constructions have to conform to building standards and regulations. Material properties must be reproducible in standardised test procedures. This also applies for the control of the quality of production of earth building materials and constructions. Building conservation is a part of this process. Generally, national building standards have to reflect the current situation of building materials / construction systems of that country for which they have been developed.
When pushed to the limits of their detection capability, NDE systems do not produce consistent hit/miss
indications. Their capability of detecting small defects is therefore expressed in terms of POD. An adequate
NDE system is required to ensure the structural integrity. In conventional signal response analysis, the POD is
expressed as a function of the defect size, and its adequacy for the inspection task is tested against the maximum
allowable defect size which will not undermine the structural integrity. Analyses of modern structures show that
other parameters, beside the defect size, can both significantly influence the POD and determine the severity of
the defect for the structure. Within the multi-parameter reliability analysis, the POD is expressed as a function of
those influencing parameters. When determining the adequacy of the NDE system, the capability of detecting a
defect has to be expressed and tested against the critical value of exactly that parameter that determines defects
severity for the structure. Failing to do so can lead to a rejection of the healthy, or acceptance of the bad part.
The principle is demonstrated on the example of the Transmit-Receive Longitudinal (TRL) ultrasonic inspection
of the iron cast component for semi-elliptical surface defects.
Overview of different strengthening techniques applied on walls used in historical structures
(2012)
Both in developed and developing countries, modern building materials tend to be preferred to traditional earthen construction. Reasons include low durability, inadequate performance under seismic loading and, in developing countries, a wish to replace what is perceived as 'poor' with what is perceived as 'rich'. In an age when building permissions and construction standards are a must, particularly in seismic areas, even when an owner is willing to build in earth, construction approval needs to be granted: we rely on values and standards to build, but the necessary data on material properties and structural performance of earthen building techniques is scarce if compared to the abundance of data for other materials (clay brick masonry, concrete, steel) available to the engineer. At the same time, traditional builders' skills, knowledge and confidence in earthen building techniques are decreasing if not disappearing. A wallette testing campaign was thus carried out with the aim of filling this knowledge gap. Prior to the wallette campaign, material properties, including composition and physical-mechanical parameters, were determined. Compression and diagonal compression (shear) tests were then performed, and a basic analysis of the mechanical behaviour of structural elements built in cob is provided in relation to earth block (adobe) masonry and rammed earth elements. Cob, shown to have low compressive resistance, has a relatively ductile post-peak behaviour if compared to earth block masonry specimens which, as expected, show a marked brittle behaviour. In terms of shear strength, cob performs relatively well in view of its low compressive strength. The study is part of our work within the framework of the ongoing project NIKER funded by the European Commission dealing with improving the structural performance of Cultural Heritage assets in order to limit earthquake hazards.
Water-repellent renders were studied in order to evaluate their suitability for restoration applications. Water repellent admixtures, such as powdered siloxane-based products and metal soaps (zinc and calcium stearates), were mixed with a pozzolana-lime binder similar to historical binders with hydraulic properties. The chemical-physical and structural properties, the effectiveness and the durability of the water-repellent mortars in different environmental conditions were studied. The influence of the water repellent admixtures was evaluated by FT-IR analyses, by testing the mechanical properties and the behaviour in presence of water. The durability of the water-repellent mortars was evaluated after the exposure to artificial weathering (UV-light and water) and to immersion/drying cycles in saturated sodium sulphate solution. The nature of the water-repellent admixtures influenced both the hydration reactions and the chemical-physical properties of the mortars resulting in different resistance to the weathering and to salt crystallization.
Der Large Hadron Collider (LHC) des europäischen Kernforschungszentrums CERN ist einer der weltweit größten und leistungsfähigsten Teilchenbeschleuniger. Um den Teilchenstrahl auf seiner Kreisbahn zu halten, werden mit Hilfe supraleitender Spulen sehr starke Magnetfelder erzeugt. Die hierzu benötigten hohen Ströme werden über Verbunddrähte aus Niob-Titan und Kupfer geleitet.
Die Drähte werden u.a. durch Ultraschallschweißungen miteinander verbunden. Eine mangelhafte Verbindung kann zur Erwärmung der Kontaktstelle und in Folge davon zum Zusammenbruch der Supraleitung führen. Auf Anfrage des CERN wurden an der BAM Untersuchungen zur Prüfbarkeit solcher Verbindungen bei Umgebungstemperatur durchgeführt. Es gelang, für einen Verbindungstypen einen Wirbelstromsensor für eine manuelle Prüfung zu entwickeln. Ein Prototyp des Sensors befindet sich beim CERN in der praktischen Erprobung. Das Sensorprinzip sowie Prüfergebnisse aus Labor und Praxis werden vorgestellt.
Sintering and foaming of barium and calcium silicate glass powder compacts have been studied for different powder milling. Sintering was measured by means of heating microscopy backed up by XRD, DTA, Vacuum Hot Extraction (VHE) and electron microscopy. Foaming intensity strongly increased with decreasing glass partiefe size. Although powder compacts were uniaxially pressed and sintered in ambient air, foaming was affected by the milling atmosphere and most intensive for milfing in C02. Conformingly, VHE studies revealed that foaming of fully sintered samples was mainly driven by C02, even for powders milled in technical air, Ar and N2. Prolonged storage of air milled barium silicate glass powders in ambient air before pressing and sintering caused further increase of foaming intensity. These findings indicate that carbonaceous species are preferentially trapped to or close beneath the powder surface during milling and later storage. The temperature range of C02 degassing from fully sintered barium and calcium silicate g/ass powder compacts fits the temperature ranges of decomposition of BaC03 and CaC03 mix-milled with the respective barium and calcium silicate glass powders.
DIN 50100 definiert die Bedingungen für den Schwingfestigkeitsversuch, der zur Ermittlung von Kennwerten dient, die das Verhalten metallischer Werkstoffe und Bauteile bei zyklischer Beanspruchung mit einer konstanten Lastamplitude beschreiben (Wöhlerversuch). Die Norm umfasst die Versuchsdurchführung, die Versuchsauswertung sowie die Dokumentation von lastgeregelten Wöhlerversuchen im Zeit- und Langzeitfestigkeitsbereich. Mit DIN 50100 soll erreicht werden, dass die Wöhlerlinien verschiedener Prüfstellen miteinander vergleichbar und die wesentlichen Randbedingungen der Versuchsdurchführung dokumentiert werden. Da die Ergebnisse von Schwingfestigkeitsversuchen streuen, ist die Treffsicherheit für die Schätzung der Kennwerte von der Anzahl der Versuche einer Versuchsreihe abhängig. In Abhängigkeit von einer geforderten Treffsicherheit wird durch die DIN 50100 der erforderliche Stichprobenumfang vorgegeben.
An approach to achieve “zero leakage” is discussed with respect to the experience in Germany, where strict regulations for landfill lining and capping systems have been developed and issued because of large environmental problems related to landfills that accumulated in the 1970’s and 1980’s. Using a thick, high quality HDPE geomembrane (GMB), which is installed free of residual waves and wrinkles in intimate contact with a compacted clay liner (CCL) or geosynthetic clay liner (GCL) of very low permeability, by a qualified, experienced, well equipped and properly third-party controlled installer and which are protected by heavy protection layers designed with respect to long-term performance of the GMB, may result in a liner or capping system of practically no leakage. This is demonstrated by analyzing results of measurements obtained from permanently installed leak detection systems in combination with HDPE GMBs. The survey is based on 32 German landfills with 1,276,500 m² of installed HDPE GMB.
The goal of the present study is to assess the feasibility to develop a first reliable database of materials parameters for Earth Block Masonry (EBM). The database is crucial when defining the materials safety factors. In the first part an experimental campaign of compressive tests were carried out on two types of earth block and two types of earth mortar. The results showed that the mean variation of the compressive strength was remarkably less than expected. This low variation is related to a production with high quality standards of the materials employed. In the second part a partial safety factor for EBM under uniaxial compression was determined through the reliability method. The results proved the reliability of a common calculation method for EBM based on partial safety factors following the current standards.