Filtern
Dokumenttyp
Sprache
- Englisch (3)
Referierte Publikation
- ja (3) (entfernen)
Schlagworte
- Abdominal appendages (1)
- Absorption (1)
- Adult insects (1)
- Bauplan (1)
- CT (1)
- Etalon feature (1)
- Far-infrared spectroscopy (1)
- Gas diffusion electrodes (1)
- Operando cell (1)
- Total transmittance reflectance (1)
Organisationseinheit der BAM
Despite their enormous diversity, the bauplan of adult winged insects (pterygotes) is remarkably conservative since the Lower Devonian: a five-segmented head, a three-segmented thorax with three pairs of walking legs and an eleven-segmented abdomen without any non-sexual appendages 1 and 2. The only known exceptions are the abdominal appendages of adult male sepsid flies on the fourth segment; however, these are also used as copulatory organs and are supposedly maintained through sexual selection [3]. Here, we report a rod-like paired appendage from the third and fourth abdominal segments in adults of the Southeast-Asian Hemiptera taxon Bennini (Figure 1A,B; Supplemental information). These are fully musculated, innervated, and movable and bear highly organized sensory and secretory units. The appendages, termed LASSO (lateral abdominal sensory and secretory organs), are consistent in topology and structure in all species studied and not sexually dimorphic. The existence of these non-sexual abdominal appendages reveals the potential of the 300 million year old conserved bauplan of insects.
Metal-based gas diffusion electrodes are utilized in chlor-alkali electrolysis or electrochemical reduction of carbon dioxide, allowing the reaction to proceed at high current densities. In contrast to planar electrodes and predominantly 2D designs, the industrially required high current densities can be achieved by intense contact between the gas and liquid phase with the catalytically active surfaces. An essential asset for the knowledge-based design of tailored electrodes is therefore in-depth information on electrolyte distribution and intrusion into the electrode’s porous structure. Lab-based and synchrotron radiography allow for monitoring this process operando. Herein, we describe the development of a cell design that can be modularly adapted and successfully used to monitor both the oxygen reduction reaction and the electrochemical reduction of CO2 as exemplary and currently very relevant examples of gas-liquid reactions by only minor modifications to the cell set-up. With the reported cell design, we were able to observe the electrolyte distribution within the gas diffusion electrode during cell operation in realistic
conditions.
Removal of Etalon Features in the Far-Infrared–Terahertz Transmittance Spectra of Thin Polymer Films
(2020)
Etalon features in infrared spectra of stratified samples, their influence on the interpretation and methods to circumvent their presence in infrared spectra have been in discussion for decades. This paper focuses on the application of a method originally developed to remove interference fringes in the mid-infrared spectra for far-infrared Fourier transform spectroscopy on thin polymer films. We show that the total transmittance-reflectance technique, commonly used for mid-infrared, also works successfully in the far infrared spectral range where other approaches fail. Experimental spectra obtained by such technique are supported by model calculations and reveal the possibility and limits to obtain almost undisturbed far-infrared spectra which are suitable to determine low energy vibrations of ionomer salts under certain sample conditions.