Filtern
Dokumenttyp
Sprache
- Englisch (3)
Referierte Publikation
- ja (3)
Schlagworte
- Synchrotron radiation (3) (entfernen)
X-ray computed tomography is an important tool for non-destructively evaluating the 3-D microstructure of modern materials. To resolve material structures in the micrometer range and below, high brilliance synchrotron radiation has to be used. The Federal Institute for Materials Research and Testing (BAM) has built up an imaging setup for micro-tomography and -radiography (BAMline) at the Berliner storage ring for synchrotron radiation (BESSY). In computed tomography, the contrast at interfaces within heterogeneous materials can be strongly amplified by effects related to X-ray refraction. Such effects are especially useful for materials of low absorption or mixed phases showing similar X-ray absorption properties that produce low contrast. The technique is based on ultra-small-angle scattering by microstructural elements causing phase-related effects, such as refraction and total reflection. The extraordinary contrast of inner surfaces is far beyond absorption effects. Crack orientation and fibre/matrix debonding in plastics, polymers, ceramics and metal-matrix-composites after cyclic loading and hydro-thermal aging can be visualized. In most cases, the investigated inner surface and interface structures correlate to mechanical properties. The technique is an alternative to other attempts on raising the spatial resolution of CT machines.
X-ray refraction topography techniques are based on ultra-small angle scattering by micro-structural elements causing phase-related effects such as refraction and total reflection at a few minutes of arc as the refractive index of X-rays is nearly unity. The refraction contrast is several times higher than true absorption and results in images of cracks, pores and fibre debonding separations below the spatial resolution of the detector. In most cases the investigated inner surface and interface structures correlate to mechanical properties. For the exploration of micro structured materials the refraction technique has been improved by a 3D Synchrotron Refraction Computed Tomography test station. The specimen is placed in an X-ray beam between two single crystals, which suppresses all sample scattering. In addition, an asymmetric cut second crystal can magnify the image up to 50 times revealing nano meter resolution. The technique is an alternative to other attempts on raising the spatial resolution of CT machines.