High performance composites and other light weight materials are generally a comple problem to the performance of nondestructive testing methods. X-ray refraction provide unconventional X-ray scattering techniques to meet the actual demand for improve nondestructive characterization of these advanced materials. Scanning the samples across collimated narrow incident X-ray beam permits to image integral micro-structures (a present) with a resolution of 10 µm. Investigations of samples after strain-induced micro cracks and fibre debonding in impact damaged epoxy are shown.
The physics of X-ray refraction are analogous to the well known refraction of light b optical lenses and prisms, governed by Snell's law. The special feature is the deflection a very small angles of few minutes of arc, as the refractive index of X-rays in matter i nearly one. Due to the density differences at inner surfaces most of the incident X-rays ar deflected. As the scattered intensity of refraction is proportional to the specific surface of sample, a reference standard gives a quantitative measure for analytical determinations.
Figure 1 represents a two-dimensional damage distribution of an impact in a 0/90° CFR laminate of 3 mm, thickness. Unlike in ultrasonic testing, there is no shadowing effect o the successive layers. By use of X-ray refraction the exact concentration of debonde fibres is calculated for each position. Additionally the refraction allows the selection of th fibre orientation.