Steam generator (SG) tubes are part of the primary circuit of pressurised water reactors and therefore also part of the pressure retaining boundary components. Furthermore, steam generator tubes are the components which guarantee the separation between the primary and secondary circuits. Therefore the knowledge of the loss of tube integrity as soon as possible is an essential. Optimised nondestructive testing methods based on the eddy current array technique are used to find material degradation, especially intergranular stress corrosion cracks during the periodical in-service inspection. These methods are supported by the measurement of the leakage rate during operation based on radioactivity and Tritium measurement regarding a high crack grows. Shutdown criteria depending on leakage rates which are described in the operation procedures but there are no specifications about the conditions for the measured leakage. Is the leakage coming from a single crack or are there multiple cracks or is this the leakage of a critical crack. With the help of FE calculations answer about the uncertainties of leakage rate versus critical crack grows were found. Shutdown criteria must guarantee to avoid critical crack sizes, i.e. between the measured tritium activity and the critical crack size must be a safety gap.
Abhängigkeit der Echoanzeige von nutartigen Reflektoren vom Prüfkopfschallfeld und von der Frequenz
(1977)
Analysis of the dielectric and electromechanical properties of the cellular polypropylene ferroelectret films (EMFIT) evidences their high potential for the application in the air-coupled ultrasonic transducers. Simple prototype transducers, based on the EMFIT films, were developed and their high sensitivity was proved in the air-coupled ultrasonic experiment. Amplitude and delay time scanned images of the polyethylene step wedge with holes, obtained in both pulse-echo and transmission modes, demonstrate that non-contact ultrasonic imaging with EMFIT transducers is possible.
Die Vorhersage der Beanspruchung bei plastischem Versagen von zylindrischen Druckbehältern wird häufig mittels Finite Elemente Berechnungen durchgeführt. Die Berechnung der zulässigen Beanspruchung erfordert ein elastisch-plastisches Werkstoffmodell und die Berücksichtigung von nichtlinearen geometrischen Effekten. Das plastische Versagen verursacht eine gesamte Strukturinstabilität und kann nicht direkt aus der Finite Elemente Analyse bestimmt werden. In dem vorliegenden Beitrag wird die Beanspruchung für plastisches Versagen eines zylindrischen Druckbehälters mittels eines analytischen Verfahrens basierend auf einem linear elastischen ideal-plastischen Materialmodell bestimmt. Wenn Plastizität auftritt, wird zum einen der Werkstoff als inkompressibel und zum anderen der Tensor der plastischen Dehnungen als parallel zum Spannungsabweichungstensor angenommen. In diesem Fall kann die Spannungs-Dehnungs-Beziehung von Henkel angewendet werden, um den Druck zu berechnen, bei dem plastisches Fließen und Versagen eintritt. Die analytischen Ergebnisse werden von den Finite Elemente Berechnungen vollkommen bestätigt.
Contribution to the ultrasonic detection and sizing of inner wall surface breaking cracks in pipes
(1984)
Degradation of material properties significant for lifetime extension of nuclear power plants
(2010)
The discussion about the right energy sources or alternative energy generation goes around the world, mostly in connection with green-house gas reduction. Therefore, some countries have started to consider extending operation of nuclear power plants. This demands an extensive plant life management as well as the knowledge of the degradation in material properties. The Basis Safety Concept (BSC) in Germany observed this circumstance. Still, lifetime extension is not an issue in Germany due to phase out of nuclear energy. Part of the BSC is the application of non-destructive examination (NDE) methods from the beginning, i.e. from component manufacture, to the end of life. The application of a NDE method to detect and size defects in components in nuclear power plants is presented. Some material properties and their degradation during increase of operation time are also in the focus of this paper.
Einfluß des Ankoppelspaltes auf den Schallübergang bei der Ultraschallprüfung mit Schrägeinschallung
(1976)
Polypropylene based ferroelectret films exhibit a strong electromechanical activity and provide a promising solution for the air coupled ultrasonic (ACUS) transducers. Ultrasonic transmission between two air coupled ferroelectret transducers in dependence on the amplitude and polarity of the high voltage exciting pulse revealed a strongly non-linear electromechanical response of the ferroelectret transmitter which provides an increase in the transmitter efficiency. The authors present a simple model describing both promotion and competition of the piezoelectric and electrostriction contributions, as well as increase in the transducer constant under high voltage excitation. Enlargement of the inverse transducer constant of the polypropylene ferroelectret film by a factor of 4 was demonstrated. The non-linear properties of the polypropylene ferroelectrets result in a strong increase in their ACUS figure of merit under the high voltage excitation, which exceeds the results of their technological optimisation. Consequently, enhancement of the ACUS system transmission by 12 dB and signal to noise ratio by 32 dB was achieved.
The comparison of probes for the inspection of cladding shows a remarkable fact: depending on the reflectors used, a different performance characterization of the probe must be expected. It seems important for performance demonstration trials - especially those including the underclad area - to use reflector types as close as possible to the real cracks to be detected. For different detection approaches, reflectors representing underclad cracks should have a reduced diffraction at the crack tip areas in order to check their potential to detect the indication based on surface reflections of the ultrasonic waves.
Dielectric and electromechanical properties of the cellular polypropylene ferroelectret films (EMFIT), combining strong piezoelectric response with a low density and softness, evidence their high potential for the air-coupled ultrasonic applications. The disadvantage of the low coupling factor is compensated by the extremely low acoustic impedance, which provides excellent matching to air and promises efficient sound transmission through the airtransducer interface. The influence of the electrodes on the electromechanical properties was investigated. Electron beam evaporation technology was adapted to the EMFIT films, and films with both-sided Au and Al electrodes were prepared without reducing or suppressing of the electromechanical properties. Finally, prototype transducers based on the EMFIT films were developed. In spite of the simple construction and absence of matching layers, high sensitivity of the EMFIT transducers was proved in the air-coupled ultrasonic experiment. Amplitude and delay time scanned images of the polyethylene step wedge with holes, obtained in both pulse-echo and transmission modes, demonstrate that non-contact ultrasonic imaging and testing with EMFIT transducers is possible.
Für die luftgekoppelte Ultraschall-Prüfung wird der Prototyp eines neuartigen Prüfkopfes vorgestellt. Statt eines piezokeramischen Ultraschall-Wandlers mit einer λ/4-Anpassschicht wird eine Ferroelektret-Folie aus schaumförmigem Polypropylen eingesetzt. Durch die außerordentlich geringe akustische Impedanz der Folie reduzieren sich die Reflexionsverluste an den Grenzschichten zur Luft so stark, dass bei diesem Prüfkopf auf eine λ/4-Anpassschicht verzichtet werden kann. Außerdem ist die Folie hochspannungsfest. Sie konnte mit Spannungen von mehr als 3500 V angesteuert werden und erlaubte eine Vorspannung am Ultraschall-Wandler des Empfangsprüfkopfes von 2000 V. Mithilfe der hohen Anregungsspannung stieg die Amplitude des akustischen Prüfimpulses auf das 11,2-Fache. Die Empfindlichkeit des Empfängers erhöhte sich durch die Vorspannung weiter um den Faktor 4,3. Insgesamt steigt die Amplitude am Empfänger also auf das 48-Fache, bei gleichbleibendem Rauschpegel. Ein abschließender Vergleich mit kommerziellen Luftultraschall-Prüfköpfen belegt die Überlegenheit der Folien-Prüfköpfe. Damit rückt der Einsatz einer vollwertigen Impuls-Echo-Technik auch bei der luftgekoppelten Ultraschallprüfung deutlich näher.