Filtern
Dokumenttyp
- Zeitschriftenartikel (7)
- Vortrag (6)
- Posterpräsentation (6)
- Sonstiges (1)
Schlagworte
- LFIA (6)
- BPA (5)
- Immunoassay (5)
- Bisphenol A (4)
- ELISA (4)
- DCF (3)
- FPIA (3)
- Schnelltest (3)
- Antibody (2)
- Diclofenac (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (6)
Bisphenol A (BPA), a monomer commonly used to manufacture polycarbonate plastic products and the epoxy resins that line metal cans, has resulted in an increased human exposure because both products come in contact with food and beverages. Since BPA is an endocrine disruptor excessive exposure could affect human reproductive function. In response, various countries have adopted a range of measures, from voluntary reductions to outright bans of BPA in some products, mostly in baby bottles and containers for canned foods. Pregnancy-test like strips in combination with hand-held readers provide a simple and versatile tool to determine the presence of bisphenol A quantitatively, making it a very attractive analytical approach especially for on-site applications at critical points, such as environmental analysis, consumer protection, and materials testing.
Diclofenac (DCF) is a non-steroidal anti-inflammatory drug (NSAID) with analgetic, anti-inflammatory, and antipyretic properties. The mechanism of action of diclofenac, like that of other NSAIDs, involves inhibition of cyclooxygenase (COX-1 and COX-2). Another pharmacological effect is preventing of prostaglandin synthesis in vitro. Prostaglandins are mediators of inflammation, because diclofenac is an inhibitor of prostaglandin synthesis.
A method has been developed to analyse for diclofenac (DCF) in the milk.
An immunochromatographic assay for the determination of bisphenol a releases from plastic materials
(2018)
Background. The worldwide increase in the use of bisphenol A (BPA), a monomer commonly used to manufacture polycarbonate plastic products and the epoxy resins that line metal cans, has resulted in an increased human exposure because both products come in contact with food and beverages. Since BPA is an endocrine disruptor excessive exposure could affect human reproductive function. In response, various countries have adopted a range of measures, from voluntary reductions to outright bans of BPA in some products, mostly in baby bottles and containers for canned foods. Nonetheless, consumers would certainly appreciate a quick test for their own assessment of contaminations by bisphenol A.
Methods. An immunochromatographic test strip was developed. This lateral-flow immunoassay (LFIA) is based on anti-BPA antibodies (from mouse) conjugated with gold nanoparticles as the marker, deposited in an elaborate pad. To form control and test zones, anti-mouse antibody and a BPA-BSA conjugate were spotted on the nitrocellulose membrane, respectively.
Results. Negative samples are revealed by red lines both in the test and control zones, respectively, whereas positive samples produce a single red line only in the control zone. The limit of detection (LOD) was found to be 0.05 µg/l, visually detected by the naked eye within 5 minutes. In addition, the intensities at the test line can be read by dedicated lateral flow readers (opTrilyzer® and Cube by opTricon, Berlin) for a more precise and documented determination.
Conclusion. Pregnancy-test like strips in combination with hand-held readers provide a simple and versatile tool to determine the presence of bisphenol A quantitatively, making it a very attractive analytical approach especially for on-site applications at critical points, such as environmental analysis, consumer protection, and materials testing.
BPA is a chemical commonly used in the production of polymer-based materials that can have detrimental effects on the thyroid gland and impact human reproductive health. Various expensive methods, such as liquid and gas chromatography, have been suggested for detecting BPA.
The fluorescence polarization immunoassay (FPIA) is an inexpensive and efficient homogeneous mix-and-read method that allows for high-throughput screening. FPIA offers high specificity and sensitivity and can be carried out in a single phase within a timeframe of 20–30 min. In this study, new tracer molecules were designed that linked the fluorescein fluorophore with and without a spacer to the bisphenol A moiety. To assess the influence of the C6 spacer on the sensitivity of an assay based on the respective antibody, hapten–protein conjugates were synthesized and assessed for performance in an ELISA setup, and this resulted in a highly sensitive assay with a detection limit of 0.05 µg/L. The lowest limit of detection was reached by employing the spacer derivate in the FPIA and was 1.0 µg/L, working range from 2 to 155 µg/L. The validation of the methods was conducted using actual samples compared to LC–MS/MS, which served as the reference method. The FPIA and ELISA both demonstrated satisfactory concordance.
Mycotoxins are toxic secondary metabolites produced by filamentous fungi. The contamination of mycotoxins in food and feed products has been recognized to be an important safety issue for human and animal health. In the context of food safety, medical herbs nowadays are also considered as potential source of mycotoxins. Considering that mycotoxins are generally stable compounds and could not be destroyed completely during food-processing operations, prevention of contamination is identified as main issue.
Currently, biochemical, and immunochemical methods based on the use of antibodies as a specific recognition bioreagents are increasingly found to be applied in screening. Along with good common enzyme linked immunosorbent assay (ELISA), more and more widely used method is fluorescence polarization immunoassay (FPIA). These methods help to monitor of many toxic substances in large number of samples and carried out quickly, easily, cheaply, and give good results in quantifying the one or more substances. That is why the use of immunochemical methods of analysis, such as ELISA and FPIA, is the most promising for solving this problem.
Thus, the aim of our work is to optimize the determination of mycotoxins by ELISA and FPIA in medical herbs. We selected antibodies and a tracer for the FPIA, then we constructed obtained a calibration curve and determined the sensitivity of this method for the samples in aqueous media. Then, the optimal sample preparation was elaborated: for spiked nuts samples were selected and prepared and a calibration curve was obtained with respect to the matrix effect. After that, the analysis of spiked nuts samples was performed by ELISA and FPIA and the sensitivity of both methods was compared.
One of the most important chemicals used in the production of polymer plastics and coatings is bisphenol A. However, despite the large number of studies on the toxicity and hormonal activity of BPA, there are still open questions and thus considerable media attention regarding BPA toxicity. Hence, it is necessary to develop a sensitive, simple, cost-efficient, specific, portable, and rapid method for monitoring bisphenol A and for high sample throughput and on-site screening analysis. Lateral flow immunoassays have potential as rapid tests for on-site screening. To meet sensitivity criteria, they must be carefully optimized. A latex microparticle-based LFIA for detection of BPA was developed. The sensitivity of the assay was improved by non-contact printing of spot grids as the control and test lines with careful parameter optimization. Results of the test could be visually evaluated within 10 min with a visual cut-off of 10 µg/L (vLOD). Alternatively, photographs were taken, and image analysis performed to set up a calibration, which allowed for a calculated limit of detection (cLOD) of 0.14 µg/L. The method was validated for thermal paper samples against ELISA and LC–MS/MS as reference methods, showing good agreement with both methods
A lateral flow immunoassay (LFIA) using latex particles labeled with antibody to BSAclarithromycin (CLA) was developed for the rapid simultaneous group determination of six macrolide antibiotics. Optimization of antigen spotting on the membrane and latex probe loading allowed improving visual detectability (vLOD) 100 times, which was 1, 1, 10, 10, 50, and 1000 ng/mL for CLA, roxithromycin, erythromycin, dirithromycin, azithromycin, and oleandomycin in buffer, respectively. The calculated limits of instrumental detection (cLOD) were respectively 0.12, 0.15, 1.4, 2.1, 2.4, and 3.3 ng/mL. To avoid a strong influence of breast milk of a very diverse and variable composition, a sample pretreatment is proposed. The six macrolides mentioned can be visually detected in breast milk after 20 minutes pretreatment at concentrations of 10-1000 ng / ml or instrumentally with cLOD of 4.0, 2.5, 30, 42, 42 and 180 ng/mL. The recovery rate from the spiked samples carried out using a strip scanner device ranged from 71% to 110%, and precision expressed as relative standard deviation was between 3-14%. The described rapid on-site diagnostic assay format can be useful for monitoring the content of antibiotics in breast milk during macrolide treatment to ensure safe breastfeeding of infants.
Bisphenol A (BPA) is a common industrial chemical that is widely used as a monomer or additive in the production of polymer materials. This substance causes impairment of the childbearing function, acceleration of sexual aging, negatively impacts the brain, and also contributes to the development of certain oncological diseases, as well as increasing the risk of a fetus developing the Down syndrome. But the biggest downside of bisphenol is the fact that it accumulates in the system during its use, as well as after. Many methods have been proposed for the determination of BPA, in particular, gas and liquid chromatography. The main disadvantages of such approaches are the high cost of the equipment, the significant duration of an analysis, and difficulties in screening a large number of samples. Immunoanalytical techniques attributes are high throughput, high specificity and sensitivity, as well as low cost and simplicity. Particularly interesting as a quick test for screenings is the lateral flow immunoassay (LFIA), a format widely in use for the detection of pregnancy. LFIA for BPA have been described before, but lack sensitivity.
In this work, focuses on the conjugation (by passive adsorption) efficiency of the different monoclonal antibodies with 40 nm gold nanoparticles. The effect of factors such as pH value and concentration of antibody has been quantificationally discussed using spectra methods after adding 10% NaCl which induced gold nanoparticle aggregation. Consequently, 40 nm gold nanoparticles should be labeled with antibody under optimal pH value and optimal concentrations of antibody. It will be helpful for the application of antibody-labeled gold nanoparticles for the determination of bisphenol A in aqueous solutions (water from different sources, leachates and extracts).