The need for the traceable characterization of fluorescence instruments is emphasized from a chemists point of view, focusing on spectral fluorescence standards for the determination of the wavelength- and polarization-dependent relative spectral responsivity and relative spectral irradiance of fluorescence measuring systems, respectively. In a first step, major sources of error of fluorescence measurements and instrument calibration are revealed to underline the importance of this issue and to illustrate advantages and disadvantages of physical and chemical transfer standards for generation of spectral correction curves. Secondly, examples for sets of traceable chemical emission and excitation standards are shown that cover a broad spectral region and simple procedures for the determination of corrected emission spectra with acceptable uncertainties are presented. With proper consideration of the respective measurement principle and geometry, these dye-based characterization procedures can be not only applied to spectrofluorometers but also to other types of fluorescence measuring systems and even to Raman spectrometers.
With the Calibration Kit Spectral Fluorescence Standards BAM-F001BAM-F005, we developed a simple
tool for the characterization of the relative spectral responsivity and the long-term stability of the emission channel of
fluorescence instruments under routine measurement conditions thereby providing the basis for an improved comparability
of fluorescence measurements and eventually standardization. This first set of traceable fluorescence standards,
which links fluorescence measurements to the spectral radiance scale in the spectral range of 300770 nm and has been optimized for spectrofluorometers, can be employed for different measurement geometries and can be adapted to different fluorescence techniques with proper consideration of the underlying measurement principles.
Problems associated with the measurement of photoluminescence are briefly reviewed, including relevant instrument parameters affecting these measurements. Procedures for the characterization of relevant instruments are discussed, focusing on spectrofluorometers, and fit-for-purpose methods including suitable standards are recommended. The aim here is to increase the awareness of the importance of reliable instrument characterization and to improve the comparability of measurements of photoluminescence.
This report summarizes problems associated with the comparability of measurements of photoluminescence and procedures for the characterization of relevant instruments, focusing on physical and chemical fluorescence standards. To provide recommendations on selecting and using such standards, we derive general and scope-specific requirements and quality criteria for suitable devices and materials and briefly address metrological requirements linked to the realization of comparable measurements. Special emphasis is dedicated to liquid and solid chromophore-based fluorescence standards developed or currently tested by us.
Immunologische Verfahren haben während der vergangenen Jahrzehnte eine große Verbreitung in der Medizin gefunden. Grundlage dieser Verfahren ist die spezifische Bindung zwischen Antigen und Antikörper. Eine der wichtigsten Methoden zum sensitiven und quantitativen Nachweis biologisch relevanter Moleküle ist hierbei der Enzyme Linked Immunosorbent Assay (ELISA).
Unter dem Aspekt der zahlreichen Einsatzgebiete ist die Frage nach Messunsicherheiten bei der Konzentrationsbestimmung von Biomolekülen mittels ELISA aus metrologischer Sicht von großem Interesse. Eine erhebliche Herausforderung stellt hierbei die Vielzahl von Einflussgrößen dar, die zudem hinsichtlich ihrer Messunsicherheit nur schwer zu quantifizieren sind. In Hinblick auf den Einsatz der Assays im Bereich der Laboratoriumsmedizin besteht die Notwendigkeit, Genauigkeit und Zuverlässigkeit dieser Messverfahren zu validieren. Zu diesem Zwecke wurden im Rahmen einer CCQM-Studie (CCQM- Comité consultatif pour la quantité de matiè re - métrologie en chimie ) internationale Vergleichsmessungen an einem ELISA zur Zytokinbestimmung (humanes Interferon-a) durchgeführt, an denen sich die PTB beteiligt hat.
To improve the reliability of fluorescence data in the life and material sciences and to enable accreditation of fluorescence techniques, standardization concepts are required that guarantee and improve the comparability of fluorescence measurements. At the core of such concepts are simple and evaluated fluorescence standards for the consideration of instrument-specific spectral and intensity distortions of measured signals and for instrument performance validation (IPV). Similarly in need are fluorescence intensity standards for the quantification from measured intensities and for signal referencing, thereby accounting for excitation light-induced intensity fluctuations. These standards should be preferably certified, especially for use in regulated areas like medical diagnostics. This encouraged us to develop liquid and solid standards for different fluorescence parameters and techniques for use under routine measurement conditions in different formates. Special emphasis was dedicated to the determination and control of the spectral responsivity of detection systems, wavelength accuracy, homogeneity of illumination, and intensity referencing for e.g. spectrofluorometers, fluorescence sensors and confocal laser scanning fluorescence microscopes. Here, we will present design concepts and examples for mono- and multifunctional fluorescence standards that provide traceability to radiometric units and present a first step towards a toolbox of standards.
Prerequisite for the rational design of functional organic materials with tailor-made electronic properties is the knowledge of the structure–property relationship for the specific class of molecules under consideration. This encouraged us to systematically study the influence of the molecular structure and substitution pattern of aromatically substituted 1,3,4-oxadiazoles on the electronic properties and packing motifs of these molecules and on the interplay of these factors. For this purpose, seven diphenyl-oxadiazoles equipped with methyl substituents in the ortho- and meta-position(s) were synthesized and characterized. Absorption and fluorescence spectra in solution served here as tools to monitor substitution-induced changes in the electronic properties of the individual molecules whereas X-ray and optical measurements in the solid state provided information on the interplay of electronic and packing effects. In solution, the spectral position of the absorption maximum, the size of Stokes shift, and the fluorescence quantum yield are considerably affected by ortho-substitution in three or four ortho-positions. This results in blue shifted absorption bands, increased Stokes shifts, and reduced fluorescence quantum yields whereas the spectral position and vibrational structure of the emission bands remain more or less unaffected. In the crystalline state, however, the spectral position and shape of the emission bands display a strong dependence on the molecular structure and/or packing motifs that seem to control the amount of dye–dye-interactions. These observations reveal the limited value of commonly reported absorption and fluorescence measurements in solution for a straightforward comparison of spectroscopic results with single X-ray crystallography. This underlines the importance of solid state spectroscopic studies for a better understanding of the interplay of electronic effects and molecular order.
We present a novel, simple, and fast colorimetric method to quantify the total number of carboxy groups on polymer microparticle and nanoparticle surfaces. This method exploits that small divalent transition metal cations (M2+ = Ni2+, Co2+, Cd2+) are efficiently bound to these surface functional groups, which allows their extraction by a single centrifugation step. Remaining M2+ in the supernatant is subsequently quantified spectrophotometrically after addition of the metal ion indicator pyrocatechol violet, for which Ni2+ was identified to be the most suitable transition metal cation. We demonstrate that the difference between added and detected M2+ is nicely correlated to the number of surface carboxy groups as determined by conductometry, thereby affording a validated measure for the trueness of this procedure. The variation coefficient of ~5% found in reproducibility studies underlines the potential of this novel method that can find conceivable applications for the characterization of different types of poly(carboxylic acid)-functionalized materials, e.g., for quality control by manufacturers of such materials.
We introduce a method to determine the number of accessible functional groups on a polymer microsphere surface based on the interaction between the macrocyclic host cucurbit[7]uril (CB7) and a guest reacted to the microsphere surface. After centrifugation, CB7 in the supernatant is quantified by addition of a fluorescent dye. The difference between added and detected CB7 affords the number of accessible surface functional groups.