Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (34)
- Zeitschriftenartikel (13)
- Vortrag (9)
- Beitrag zu einem Sammelband (2)
- Posterpräsentation (1)
Schlagworte
- Concrete (8)
- Fatigue (8)
- Beton (5)
- Ermüdung (4)
- CFD (3)
- Fire (3)
- Monitoring (3)
- Photogrammetry (3)
- Rheology (3)
- Rice husk ash (3)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (9)
Industrial wastes (bottom ash, crushed concrete fines, filter residue, paper ash and lignite fly ash) have potential for use in building materials, for instance as raw materials for clinker production, as supplementary cementitious materials (SCMs) or mineral additions in concrete. The properties of the products are dependent on the reactivity of the waste materials used, which can be classified as inert, latent hydraulic or pozzolanic. In this study, waste materials were first characterised. This was followed by theoretical considerations of the mentioned application options. Experiments were limited to evaluation of potential as SCMs and, for this purpose, activity index measurements and calorimetric and thermogravimetric analyses were performed. Finally, the synergetic effects of various waste materials were considered. Paper ash (calcium oxide source) and filter residue (amorphous silicon dioxide source) showed the best prospects for use as cementitious material components.
Fires in road tunnels constitute complex scenarios with interactions between the fire, tunnel users and safety measures. More and more methodologies for risk analysis quantify the consequences of these scenarios with complex models. Examples for complex models are the computational fluid dynamics model Fire Dynamics Simulator (FDS) and the microscopic evacuation model FDS+Evac. However, the high computational effort of complex models often limits the number of scenarios in practice. To balance this drawback, the scenarios are often simplified. Accordingly, there is a challenge to consider complex scenarios in risk analysis.
To face this challenge, we improved the metamodel used in the methodology for risk analysis presented on ISTSS 2016. In general, a metamodel quickly interpolates the consequences of few scenarios simulated with the complex models to a large number of arbitrary scenarios used in risk analysis. Now, our metamodel consists of the projection array-based design, the moving least squares method, and the prediction interval to quantify the metamodel uncertainty. Additionally, we adapted the projection array-based design in two ways: the focus of the sequential refinement on regions with high metamodel uncertainties; and the combination of two experimental designs for FDS and FDS+Evac.
To scrutinise the metamodel, we analysed the effects of three sequential refinement steps on the metamodel itself and on the results of risk analysis. We observed convergence in both after the second step (ten scenarios in FDS, 192 scenarios in FDS+Evac). In comparison to ISTSS 2016, we then ran 20 scenarios in FDS and 800 scenarios in FDS+Evac. Thus, we reduced the number of scenarios remarkably with the improved metamodel. In conclusion, we can now efficiently integrate complex scenarios in risk analysis. We further emphasise that the metamodel is broadly applicable on various experimental or modelling issues in fire safety engineering.
Methodologies on fire risk analysis in road tunnels consider numerous factors affecting risks (risk indicators) and express the results by risk measures. But only few comprehensive studies on effects of risk indicators on risk measures are available. For this reason, this study quantifies the effects and highlights the most important risk indicators with the aim to Support further developments in risk analysis. Therefore, a system model of a road tunnel was developed to determine the risk measures.
The system model can be divided into three parts: the fire part connected to the fire model Fire Dynamics Simulator (FDS); the evacuation part connected to the evacuation model FDS+Evac; and the frequency part connected to a model to calculate the frequency of fires. This study shows that the parts of the system model (and their most important risk indicators) affect the risk measures in the following order: first, fire part (maximum heat release rate); second, evacuation part (maximum preevacuation time); and, third, frequency part (specific frequency of fire). The plausibility of These results is discussed with view to experiences from experimental studies and past fire incidents.
Conclusively, further research can focus on these most important risk indicators with the aim to optimise risk analysis.
Safety measures like tunnel emergency Ventilation Systems cause high financial costs. Hence, safety measures have to be chosen with the focus on the expected reduction of the consequences like fatalities or damage on structures and in conjunction with the investments. Since 2004, the European directive EU 2004/54/EC proposes therefore the application of risk assessments. Because the EU directive provides only few legal requirements on risk assessments, the methodologies developed on this basis have large differences. After one decade of intensive research, the comparative study now highlights common aspects and differences of several methodologies.
Within a current research project which is funded by the German Research Foundation (DFG) the influence of the size and the geometry of specimens on the spalling result in fire tests is going to be investigated at Bundesanstalt für Materialforschung und -prüfung (BAM). This paper describes some preliminary results and a newly developed test setup. The novel setup enables the efficient and precise quantification of spalling by using a special photogrammetric measurement system.
Based on methane from renewable resources, LNG is an alternative fuel for heavy and long-distance traffic in land transport. Contrary to its positive properties, the fuel contains risks from an explosion and extremely low temperatures for personal and infrastructure safety. CFD-models are suitable for doing risk analyses for arbitrary scenarios. For examining how to model for risk research the dispersion of LNG-vapor, this paper contains a model variant study, with an evaluation by experiments.
This paper describes the use of the CFD-code ANSYS Fluent for simulating experiments of the ‘LNG Safety Program Phase II‘. The content of the well-documented experiments was the research of the vaporization rate of LNG on land and the dispersion of LNG-vapor in the air. Based on the comparison to two experiments, overall 12 CFD-model variants with varying thermal and turbulence parameters were examined how they affect the transient LNG-vapor dispersion in air.
The definition of turbulence-boundary-condition at the domain borders had the biggest impact on modeling, followed by the turbulence model. The most accurate model variant had been applied for observing the spreading behavior of LNG-vapor in the air after evaporation on land and analyzing the influence of the LNG-composition to the dispersion. The results show that the mixture of LNG-vapor and the air in the free field is cooler than the ambient air and spreads like a heavy gas on the ground.
Wärmebehandlung und Autoklavierung von UHPC - Neue Perspektiven für die Betonfertigteilindustrie
(2011)
Das Gefüge von UHPC ist durch eine dicht gepackte und fehlstellenarme Matrix gekennzeichnet. Eine zusätzliche Optimierung ist durch eine Wärmebehandlung bzw. hydrothermale Nachbehandlung (Autoklavierung) unter einem Wasserdampfsättigungsdruck möglich. Die Wärmebehandlung von Beton ist ein in der Betonfertigteilindustrie geläufiges Verfahren, um die Erstarrungszeit zu verkürzen und höhere Frühfestigkeiten zu erreichen.
The worldwide spread of windfarms brings new challenges, especially for concrete structures as a part of towers, connecting joints and foundations of wind turbines. High-cyclic loadings in such structures lead to a high relevance of the subject of fatigue. A proper assessment of the fatigue strength of concrete demands therefore a basis of reliable experimental data and the development of standardized testing methods. This article presents first results of an ongoing research program of BAM (Bundesanstalt für Materialforschung und -prüfung) which is a part of a joint project (WinConFat) funded by the German Federal Ministry for Economic Affairs and Energy. The subproject investigates the effects of size and slenderness of the specimens on the fatigue behaviour of high strength concrete at different stress levels. Not only the fatigue strength, but also the fatigue process itself is monitored by means of several measurement methods. Strain measurements are used to calculate the load dependent elastic modulus in the fatigue hysteresis as indicators for fatigue development. Furthermore, the application of non-destructive methods like acoustic emission analysis and ultrasonic measurement in laboratory tests gives a deeper insight into damage processes under cyclic loading. The results shall be used to improve design rules for concrete members under fatigue load and to develop or improve non-destructive techniques for in-service structural health monitoring.
Die heute in der Anwendung befindlichen Bemessungskonzepte für Ermüdung von Beton stammen zum Teil noch aus den 1990er Jahren und sind speziell hinsichtlich hochfester Betone konservativ ausgelegt. Um die Vorteile von Türmen für Windkraftanlagen, vor allem auch aus hochfesten Betonen, im Zuge des geplanten Ausbaus der Windenergieversorgung in Deutschland wirtschaftlich nutzbar zu machen, müssen diese Bemessungskonzepte weiterentwickelt werden. Dafür sind umfangreiche Untersuchungen zur Ermittlung von Bruchlastwechselzahlen und zur Charakterisierung der Schädigungsentwicklung unter Ermüdungsbeanspruchung erforderlich. Allgemein anerkannte bzw. verbindliche Regelwerke oder Verfahren zur experimentellen Bestimmung der Ermüdungsfestigkeit (Bruchlastwechselzahlen) an Betonproben gibt es zurzeit aber nicht und die bisher durchgeführten Untersuchungen variieren in Parametern wie Probengeometrie, Probengröße und Prüffrequenz. Eine vergleichende Analyse der Ergebnisse der Studien und insbesondere die Übertragbarkeit auf bauteilrelevante Abmessungen ist auf dieser Grundlage nur sehr eingeschränkt möglich.
Die zunehmende Anwendung hochfesten Betons in ermüdungsbelasteten Bauwerken, herausfordernde Belastungsszenarien im Bereich von On- und Offshore Windenergieanlagen bezüglich sehr hoher Lastwechselzahlen sowie das gleichzeitige Streben nach energie- und ressourcenschonendem Bauen stellen die Bemessung von Beton gegen Ermüdung vor neue Aufgaben. Eine Vielzahl von Studien beschreibt bereits die Auswirkung von Einflussfaktoren wie Mischungszusammensetzung, Feuchte, Probekörpergröße oder Belastungsart auf die Ermüdungsfestigkeit und den Ermüdungsprozess. Aufgrund der unterschiedlichen Geometrien und Mischungen der in den verschiedenen Studien verwendeten Proben sind die Auswirkungen der Einflussfaktoren jedoch kaum miteinander vergleichbar. In dem vom Bundesministerium für Wirtschaft und Klimaschutz (BMWK) geförderten Verbundprojekt WinConFat wurden deshalb verschiedene Einflussfaktoren gezielt an Proben mit einheitlichen Mischungen untersucht. Das durch die Bundesanstalt für Materialforschung und -prüfung (BAM) bearbeitete Teilprojekt fokussierte sich auf den „Einfluss der Probengeometrie und -größe auf die Ermüdung von Beton“. Neben der Erhebung von Daten zur Ermüdungsfestigkeit wurde der Ermüdungsprozess mit zerstörungsfreien Prüf- und Messmethoden untersucht. Diese Prüfmethoden wurden auch hinsichtlich ihrer Anwendbarkeit zur Erfassung der ermüdungsbedingten Schädigungsentwicklung an Betonbauwerken im Rahmen von Monitoringkonzepten bewertet. Untersucht wurden die Ermüdungsfestigkeiten und der Ermüdungsprozess an Zylindern mit drei unterschiedlichen Betonmischungen sowie unterschiedlicher Größe und Schlankheit. Die Ergebnisse dieser Untersuchungen werden im Folgenden vorgestellt und diskutiert.