Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (23)
- Vortrag (9)
- Zeitschriftenartikel (4)
- Posterpräsentation (2)
Schlagworte
- Simulation (14)
- Radiography (7)
- Modeling (5)
- Spectrum (5)
- Electron transport (4)
- Digital radiography (3)
- Elektronentransport (3)
- Probability of detection (3)
- X-ray (3)
- X-ray imaging (3)
Eingeladener Vortrag
- nein (9)
Applications of RT Modelling
(2014)
Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications and to support the preparation of written procedures. Hence, computer simulation nowadays has to be able to handle all significant properties of an NDE system with sufficient accuracy. In case of radiographic applications this includes models of the radiation source, of the interaction of radiation with materials, of the detection process, and the geometrical description of the part or the construction. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport. Simulation is a powerful tool to separate different influencing factors. Here we focus on Monte-Carlo simulation of scatter contributions within aRTist.
Radiography Benchmark 2014
(2014)
In this contribution, we present a dual high-energy X-ray imaging technique for cargo container inspection using the 'spectral high-energy X-ray attenuation method'. This method is based on attenuation of continuous highenergy spectra. The developed experimental technique consists of a betatron as high-energy (up to 7.5 MeV) X-ray source and a matrix detector with high spatial resolution (400 ìm) for digital X-ray imaging. In order to evaluate the material discrimination capability using dual high-energy X-ray imaging, a test specimen is proposed, comprising step wedges of different low and high atomic number (Z) materials. The selected X-ray spectra for the dual-energy experiments correspond to 3 MV and 7.5 MV acceleration potential of the betatron. We evaluated the ratio between low- and high-energy X-ray attenuation coefficients quantitatively based on simulated poly-energetic high-energy X-ray source spectra and the detector sensitivity using the 'analytical Radiographic Testing inspection simulation tool' (aRTist) developed at BAM. The simulated effective attenuation coefficients are compared with corresponding experimental results in order to establish a method for identification of low- and high-Z materials in the container. Finally, important applications of the proposed technique in the context of aviation security are discussed.