Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (31)
- Vortrag (24)
- Beitrag zu einem Tagungsband (18)
- Posterpräsentation (13)
- Forschungsdatensatz (1)
Schlagworte
- Chemometrics (11)
- NIR (9)
- Microplastics (8)
- Raman (7)
- Process analytical technology (6)
- Prozessanalytik (6)
- Hydroformylation (5)
- Raman spectroscopy (5)
- Reaction monitoring (5)
- Chemometrie (4)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (26)
- 1.4 Prozessanalytik (25)
- 6 Materialchemie (4)
- 6.6 Physik und chemische Analytik der Polymere (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 1.9 Chemische und optische Sensorik (1)
- 4 Material und Umwelt (1)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (1)
- 5 Werkstofftechnik (1)
- 5.3 Polymere Verbundwerkstoffe (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (24)
Hydrothermal carbonization (HTC) can be used for converting the biomass into a carbon-rich material, whose application as a fuel requires higher heating value, whereas soil amendment needs stable carbon. This work was focused on the characterization of hydrochars derived from microcrystalline cellulose. The chars were investigated using elemental analysis, Brunauer–Emmett–Teller technique, nuclear magnetic resonance spectroscopy, Raman, Fourier transform infrared, and electron spin resonance spectroscopy. Severity in temperature between 230 and 270 °C with reaction times between 2 and 10 h only affect the carbon content moderately. The results show that aromatization of HTC chars correlates well with temperature, which was further supported by the increase of organic radicals with decreasing g values at higher temperatures. Based on these results, the energetic use of chars favors mild HTC (T < 230 °C and t ≤ 6 h), while the soil amendement favors serve conditions (T ≥ 230 °C, and t > 6 h).
Zur Onlineüberwachung von Fermentationsprozessen werden zunehmend schwingungsspektroskopische (Raman-, Mittel- und Nahinfrarotspektroskopie (NIRS) und UV-/VIS- Methoden(Absorptions- und Fluoreszenzspektroskopie) in Kombination mit multivariater Auswertung eingesetzt. Anliegen dieser Arbeit war es, zu testen, welche Verfahren für die spektroskopische On- und Offlineüberwachung des Fermentationsprozesses zur biotechnologischen Herstellung einer Malariavaccine grundlegend geeignet sind und welche Messbereiche und Genauigkeiten der Vorhersage im Idealfall bei der Abwesenheit von Hefezellen erzielt werden können.
Immer im Bild mittels Prozess-Spektroskopie - Spektroskopische Methoden für die Prozessanalytik
(2012)
With a more and more general acceptance of accreditation in the field of reference materials production, and an ever increasing number of RMP accredited, accreditation bodies face applications from RMP active in the field of qualitative RM production.
While (the still valid and used for accreditation purposes) ISO Guides 34 and 35 describe in detail requirements applicable to RMP dealing with quantitative RM, accreditation bodies normally claim lack of normative requirements with respect to quantitative RM. The new ISO 17034:2016 which will be introduced in the accreditation practice over the next two to three years solves the problem pragmatically, allowing strategies for RM certification other than those for (purely) quantitative materials.
In fact, both ISO Guide 34 and the new ISO 17034 are written in a form that, at least for the overwhelming majority of requirements, may be applied to RMP of both qualitative and quantitative RM. Peculiarities may occur in homogeneity and stability testing, and the uncertainty of a purely qualitative result is still under discussion. The problem of traceability might be solved for most of the application fields considered.
The talk gives an overview of the specific problems encountered, and provides some possible solutions both for homogeneity and stability testing, the expression of uncertainty, and the statement of traceability in certificates.
Qualitative reference materials (RM) cover a wide range of the overall RM market. Proficiency testing providers attract up to a thousand of participants in PT schemes purely oriented on qualitative results. The RM used for these kinds of PT are poorly regulated, nevertheless with a more and more general acceptance of accreditation in the field of RM production and PT provision, there is an ever increasing interest in assessing producers and providers according to rules already well accepted in the field of quantitative analysis.
The basic governing document, ISO 17034:2016, is written in a form that, at least for the overwhelming majority of requirements, may be applied to both qualitative and quantitative RM. However, problems remain. In particular, the expression of uncertainty of a purely qualitative result is still unresolved, and under discussion, the latter now lasting already dozens of years.
Some handles would be needed. In the poster, existing approaches and some pragmatic, new ways to tackle the problem are displayed and discussed.
In recent years, thermoextraction/desorption-gas chromatography/mass spectrometry (TED-GC/MS) has been developed as a rapid detection method for the determination of microplastics (MP) mass contents in numerous environmentally relevant matrices and, in particular, for the measurement of polymers in water samples without time-consuming sample preparation. The TED-GC/MS method was applied to investigate a typical European municipal wastewater system for possible MP masses. Such investigations are important in view of the recent revision of the Urban Wastewater Treatment Directive. Four different representative sampling sites were selected: greywater (domestic wastewater without toilet), combined sewer, and influent and effluent of a wastewater treatment plant (WWTP). All samples were collected by fractional filtration. Filtration was carried out over mesh sizes of 500, 100, 50, and in some cases, 5 µm. Polyethylene (PE), polypropylene (PP), and polystyrene (PS) were detected in all samples, with the PE fraction dominating in all cases. Styrene-butadiene rubber which serves as an indication of tire abrasion, was only found in the influent of the WWTP. The highest MP mass contents were found in the combined sewer, so MP can become a source of pollution during heavy rain events when the capacity limits of the effluent are reached, and the polluted effluent is released uncontrolled into the environment. Based on the studies, MP retention from the WWTP could be estimated to be approximately 96%. Few trends in polymer type or mass contents were detected within the different fractions of the samples or when comparing samples to each other.