A process spectroscopic approach for the monitoring of microplastics in environmental samples
(2018)
The potential of Raman and NIR process-spectroscopic as a rapid approach for the estimation of microplastics (MP) in soil matrix were tested. For this purpose, artificial MP/soil mixture samples consisting of standard soils or sand with defined ratios of MP (0,5 – 10 mass% polymer) from polyethylene (PE), polypropylene (PP), polystyrene (PS) and polyethylene terephthalate (PET) were prepared. MP particles with diameters < 2 mm and < 125 µm were obtained from industrial polymer pellets after cryo-milling. Spectra of these mixtures were collected by (i) a process FT-NIR spectrometer equipped with a reflection probe, (ii) by a cw-process Raman spectrometer and (iii) by a time-gated Raman spectrometer using fiber-optic probes. The evaluation of process-spectra was performed by chemometric methods. Whereas MP could be detected by Raman spectroscopy in coastal sand at 0.5 mass%, in standard soil detection of MP was limited to 10 – 5 mass% with the large fraction, but samples containing particles of the 125µm mass-fraction yielded no positive result at all. One reason for the lacking sensitivity could be fluorescence by soil organic matter and thus, in a next test time-gated Raman spectroscopy was applied. However, although being indeed more sensitive to the small particles this method failed at MP < 5 mass% indicating that fluorescence was not the major problem. Finally, FT-NIR was tested. Depending on the polymer, MP contents of 0,5 or 1 mass%, respectively, could be detected in standard soils and polymers identified. Furthermore, this approach could be used for the investigation of mixtures of up to four polymers and in real-world samples from bio-waste fermenter residues.
The increasing enrichment of water bodies and soils with plastic waste leads to the accumulation of microscopic plastic particles, so-called microplastics (MP). There is an urgent need for analytical methods that help to identify and quantify MP. At present, mainly thermo-analytical and microscopic methods such as micro-infrared spectroscopy or micro-Raman are used for this purpose. The latter are usually tied to time-consuming sample enrichment and preparation, only small sample quantities (micrograms) can be examined and the evaluation of the obtained spectra can be demanding. In the context of this presentation, two approaches are presented which, via the multi-variate analysis of spectroscopic data, allow i) a new methodological approach to screening MP in contaminated soils and ii) an alternative evaluation of large (micro)-spectroscopic data sets.
First, a NIR spectroscopic method is presented which allows MP consisting of polyethylene, polyethylene terephthalate, polypropylene and polystyrene to be detected in the range of up to 0.5 mass percent. Due to short measurement times and robust technology, this approach has the potential, in contrast to thermo-analytical and micro-spectroscopic methods, to examine larger sample quantities with minimal pre-treatment.
The second approach deals with the evaluation of large data sets, as typically obtained as a result of micro-FTIR using modern FPA detectors. The micro-FTIR technique is based on the spectral recording, imaging and subsequent identification of vibration bands typical of synthetic polymers. The image data sets are large and contain spectra of numerous particles of natural and synthetic origin. Exploratory multivariate data analysis has been tested to complement existing approaches based on e.g. spectrum library searches. The core concept used was dimensionality reduction. The results not only represent an orthogonal method for checking the results obtained by an automated library search, but also revealed a group of spectra that were not recorded in the existing spectrum libraries.
An alternative spectroscopic approach for the monitoring of microplastics in environmental samples
(2017)
The increasing pollution of terrestrial and aquatic ecosystems with plastic debris leads to the accumulation of microscopic plastic particles of still unknown fate. To monitor the degree of contamination and to understand the underlying processes of turnover, analytical methods are urgently needed, which help to identify and quantify microplastic (MP). Currently, costly collected and purified materials enriched on filters are investigated both by micro-infrared spectroscopy and micro-Raman. Although yielding precise results, these techniques are time consuming and restricted to sample aliquots in the order of micrograms precluding prompt and representative information on both, larger sample numbers and realistic material volumes. To overcome these problems, here we tested Raman and NIR process-spectroscopic methods in combination with multivariate data analysis.
For this purpose, artificial MP/soil mixture samples consisting of standard soils or sand with defined ratios of MP (0,5 – 10 mass% polymer) from polyethylene, polypropylene, and polystyrene were prepared. MP particles with diameters < 2 mm and < 125 µm were obtained from industrial polymer pellets after cryomilling. Spectra of these mixtures were collected by (i) a process FT-NIR spectrometer equipped with a reflection probe, (ii) by a cw-process Raman spectrometer and (iii) by a time-gated Raman spectrometer using fiber optic probes. For the calibration of chemometric models (partial least squares regression, PLSR) 5 – 10 spectra of defined MP/soil mixtures (consisting of 1 – 4 g material each) were collected. The obtained PLSR models served for the prediction of both, polymer type and content based on the spectra of “unknown” test samples.
Whereas MP could be detected by Raman spectroscopy in coastal sand at 0.5 mass%, in standard soils detection of MP was limited to 10 – 5 mass%. The sensitivity of Raman spectroscopy could be improved by mild treatment with hydrogen peroxide. FT-NIR was suitable for the investigation of MP in standard soils in the range of 5 – 1 mass%, however, here a non-linear effect was observed at higher polymer concentrations. When mixtures of several polymers at low concentration levels were milled together, FT-NIR spectroscopy yielded false positive polymers together with unprecise quantitative information. Recently, the investigation of “real-world” samples shall be tested and compared to the results obtained by micro-FTIR and micro-Raman.
Multivariate data analysis is a universal tool for the evaluation of process spectroscopic data. In process analytics, huge amounts of information are produced i) by the many variables contained in one spectrum often exceeding 1000 (wavenumbers, wavelength, shifts…), and ii) the high number of spectra that is generated within the measurement period. Multivariate data analysis, often also called Chemometrics, help to extract the relevant information which is needed to examine and even control processes. Therefore, calibration models must be precise and robust, and moreover, must cover a wide range of variation of factors posing an influence on the process.
In this pre-conference course an introduction to both, explorative data analysis by PCA (Principal Component Analysis), and regression analysis by the most frequently used method, i.e. PLSR (Partial Least Squares Regression) is given. In principal, all optical spectroscopic methods are suited for multivariate evaluation. It will be demonstrated that under certain preconditions, even process NMR spectra can be predicted by PLSR models.
At first, basic principles of multivariate data analysis will be provided. This includes a short introduction into the concept of model building and interpretation of results. Detailed aspects of data pretreatment and calibration & validation strategies for chemometric models will be provided with own data from NIR, Raman and NMR spectroscopy.
In a first example, the development of an online compatible method for the quantification of methanol in biodiesel by PLSR is presented. This also includes the classification of biodiesel feedstocks by PCA and statistical tools which allow for the estimation of a full uncertainty budget.
The Raman spectroscopic prediction of Hydroformylation reaction in a miniplant is used to discuss shortcomings and pitfalls which may occur with the transfer of off-line models to the real processes. Design of experiment and strategies for suitable lab-scale experiments are presented as a possible way to overcome problems.
In a third application the prediction of the reactants of an esterification reaction based on process NMR data is demonstrated.
The growing need to implement sensors such as NIR or Raman spectroscopy for the in-situ monitoring of bioprocesses which follows the standards of Quality by Design is either restricted by the impact of the huge water signal or by a disturbing fluorescence background originating from compounds in the culture media. Furthermore, the characterization of the bioprocess samples is challenging due to changing conditions in course of cultivation.
Here we evaluate two different process-suitable Raman spectroscopic approaches, namely time-gated Raman which bears the potential to extract the Raman signal from the fluorescence background, and cw- Raman with NIR excitation in combination with Surface Enhanced Raman Spectroscopy- (SERS) to investigate cell-free supernatants of Escherichia coli sampled over the course of a cultivation. A confocal Raman microscope was used as a reference for the process devices. The concentration of the analytes, glucose, acetate as well as metabolites such as cAMP, AMP and amino-acids were determined by offline by High-Performance Liquid Chromatography (HPLC) to serve as reference for the calibration of the Raman and SERS spectral data.
Multivariate evaluation of the Raman and SERS spectra by Partial Least Squares Regression (PLSR) yielded for most of the analytes robust correlations at each sampling point. Repeated investigation of the off-line samples over a larger experimental period suggested not only a high reliability of the Raman data in general but also a high repeatability of the SERS experiments. Similar spectral features in different quality and signal/noise ratios were measured with all three set-ups. Major results of the comparison of the different Raman spectroscopic approaches and their combination with SERS are summarized and conclusions are drawn on which approach provides the most accurate concentration data among the target analytes.
Acknowledgement
The authors kindly thank Mario Birkholz (IHP, Frankfurt (Oder), Germany) for the opportunity to use a confocal Raman microscope, Alex Bunker and Tapani Viitala (Division of Pharmaceutical Biosciences, Centre for Drug Research, University of Helsinki, Finland).
Raman spectroscopy for online monitoring of a homogeneous hydroformylation process in microemulsion
(2021)
An important industrial reaction is hydro¬formylation for the production of aldehydes from alkenes and syngas on the basis of homogeneous catalysis. The main cost factors of the processes currently used are product selectivity and the loss of the catalysts used. Therefore, various concepts for the hydroformylation of long-chain olefins have been developed, including hydroformylation in microemulsions, which is being investigated on a mini-plant scale at the Technical University of Berlin [1]. In this study, online Raman spectroscopy of the reaction of 1-dodecene to 1-tri¬decanal in a microemulsion was performed [2]. First, an experimental design was used to obtain a good representation of the operating range in the mini plant with respect to the concentrations of five reactants in a laboratory setup [3]. Based on the Raman spectra, Partial Least Squares (PLS) models for the prediction of 1-dodecene and 1-tride-decanal were calibrated and with these the reactions were predicted on a laboratory scale. In the next step, the PLS models were applied to online spectra from a mini-plant. This resulted in promising estimates of 1-tridecanal and acceptable predictions of 1-dodecene mass fractions. The predictive power of PLS models in this particular case was limited by unexpected by-product formation which, however, can easily be compensated by an extended calibration. Hence, Raman spectroscopy is a promising technique for process analysis in microemulsions.
More than 80 representatives of SMEs, industrial companies and research institutes met on September 12 at the workshop "Challenges in Additive Manufacturing: Innovative Materials and Quality Control" at BAM in Adlershof to discuss the latest developments in materials and quality control in additive manufacturing.
In special lectures, researchers, users and equipment manufacturers reported on the latest and future developments in additive manufacturing. Furthermore, funding opportunities for projects between SMEs and research institutions on a national and European level were presented.
With a more and more general acceptance of accreditation in the field of reference materials production, and an ever increasing number of RMP accredited, accreditation bodies face applications from RMP active in the field of qualitative RM production.
While (the still valid and used for accreditation purposes) ISO Guides 34 and 35 describe in detail requirements applicable to RMP dealing with quantitative RM, accreditation bodies normally claim lack of normative requirements with respect to quantitative RM. The new ISO 17034:2016 which will be introduced in the accreditation practice over the next two to three years solves the problem pragmatically, allowing strategies for RM certification other than those for (purely) quantitative materials.
In fact, both ISO Guide 34 and the new ISO 17034 are written in a form that, at least for the overwhelming majority of requirements, may be applied to RMP of both qualitative and quantitative RM. Peculiarities may occur in homogeneity and stability testing, and the uncertainty of a purely qualitative result is still under discussion. The problem of traceability might be solved for most of the application fields considered.