Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast & cost-effective on-site analyses. Magnetic bead-based immunoassays (MBBAs) allow for implementation into an immunosensor for online testing. Particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically (chronoamperometry) on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.
Increasing contamination of environmental waters with pharmaceuticals represents an emerging threat for the drinking water quality and safety. In this regard, fast and reliable analytical methods are required to allow quick countermeasures in case of contamination. Here, we report the development of a magnetic bead-based immunoassay (MBBA) for the fast and cost-effective determination of the analgesic diclofenac (DCF) in water samples, based on diclofenac-coupled magnetic beads and a robust monoclonal anti-DCF antibody. A novel synthetic strategy for preparation of the beads resulted in an assay that enabled for the determination of diclofenac with a significantly lower limit of detection (400 ng/L) than the respective enzyme-linked immunosorbent assay (ELISA). With shorter incubation times and only one manual washing step required, the assay demands for remarkably shorter time to result (< 45 min) and less equipment than ELISA. Evaluation of assay precision and accuracy with a series of spiked water samples yielded results with low to moderate intra- and inter-assay variations and in good agreement with LC–MS/MS reference analysis. The assay principle can be transferred to other, e.g., microfluidic, formats, as well as applied to other analytes and may replace ELISA as the standard immunochemical method.
Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast and cost-effective on-site analyses. Magnetic bead-based immunoassays allow for implementation into an immunosensor for online testing. These particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.
Die zunehmende Kontamination von (Trink)-Wasser mit pharmazeutischen Rückständen stellt ein potenzielles Gesundheitsrisiko dar und verlangt nach schnellen und zuverlässigen Analysemethoden. Hierbei können antikörper-basierte Methoden helfen, da sie schnelle und kostengünstige Vor-Ort-Messungen sowie Onlineanalysen ermöglichen.
Der Übergang von konventionellen plattenbasierten Formaten, wie ELISA (Enzyme-linked Immunosorbent Assay), zu einem Immunosensor für Online-Messungen wird durch den Einsatz magnetischer Mikropartikel als mobile Messplattform ermöglicht.
Die Partikel werden dazu entweder mit dem Antikörper oder dem Analyten gekoppelt. Diese beiden Strategien werden am Beispiel zweier relevanter Kontaminanten des Wassers gezeigt: Diclofenac (DCF) & Amoxicillin (AMX), und sind leicht auf andere Analyten übertragbar. Die magnetpartikelbasierten Assays (MBBAs) weisen niedrigere Nachweisgrenzen, breitere Messbereiche sowie kürzere Analysezeiten als die entsprechenden ELISAs auf und können in einen Immunosensor mit elektrochemischer Detektion auf einem mikrofluidischen Chip integriert werden.
Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast & cost-effective on-site analyses. Magnetic bead-based immunoassays allow for implementation into an immunosensor for online testing. Particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically (chronoamperometry) on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.
Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast & cost-effective on-site analyses. Magnetic bead-based immunoassays (MBBAs) allow for implementation into an immunosensor for online testing. Particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically (chronoamperometry) on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.
Wir berichten hier über die Entwicklung plattenbasierter Magnetpartikel-Immunoassays für die Bestimmung des Breitbandantibiotikums Amoxicillin und des nicht-steroidalen Antirheumatikums Diclofenac im Trinkwasser. Für die beiden Analyten wurden unterschiedliche Ansätze entwickelt, mit partikelgebundenen Antikörpern für AMX und Analyt-gekoppelten Partikeln für DCF, die die simultane Detektion beider Kontaminanten im nanomolaren Konzentrationsbereich erlauben.
We present the development of magnetic bead-based immunoassays for two potential contaminants of drinking water: the nonsteroidal anti-inflammatory drug diclofenac and the broad-spectrum antibiotic amoxicillin. For these analytes, different assay formats were developed which can generally be transferred to other analytes. The use of magnetic beads not only enables implementation of the assays into an online system since the beads can be reversibly immobilized by applying a magnetic field. Furthermore, our MBBAs hold several advantages over the conventional ELISAs (enzyme-linked immunosorbent assays) for both analytes, such as lower limits of quantification, shorter assay duration and less washing steps required.
Strategies for the setup and miniaturization of an online immunosensor including electrochemical readout on a microfluidic chip will be discussed.
Magnetpartikelbasierte Immunoassays für die Bestimmung von Amoxicillin und Diclofenac im Trinkwasser
(2021)
Wir berichten hier über die Entwicklung von magnetpartikelbasierten Immunoassays für die Bestimmung zweier relevanter Kontaminanten des Trinkwassers: Diclofenac (DCF) und Amoxicillin (AMX). Für die beiden Analyten wurden die Assays nach unterschiedlichen Prinzipien entwickelt, die sich auch auf weitere Analyten übertragen lassen. Im Vergleich zum herkömmlichen ELISA weisen die hier entwickelten magnetpartikelbasierten Assays einen größeren Messbereich mit niedrigeren Bestimmungsgrenzen bei gleichzeitig deutlich reduzierter Analysendauer auf. Darüber hinaus können die Immunoassays in ein automatisierbares Onlinesystem zur Analyse in der Trinkwasserversorgung implementiert werden. Strategien hierfür werden erläutert.
The demand for quick and reliable online sensors is rising not only in the field of environmental analysis with new and diversifying sources of pollution. A major aspect of this is the contamination of (drinking) water with pharmaceuticals representing a potential health threat and requiring timely countermeasures in case of contamination.
In this regard, antibody-based methods can be helpful as they enable fast and cost-effective on-site and potentially online analyses. The transition from the conventional plate-based formats like ELISA (enzyme-linked immunosorbent assay) to an immunosensor fit for online sensing can be achieved by using magnetic microparticles as a mobile sensing platform.
Beads are prepared by either coupling the antibody or the analyte to the surface. Both these strategies are presented using the example of two relevant contaminants in water: diclofenac (DCF) & amoxicillin (AMX), and can be transferred to other analytes.
The developed magnetic bead-based assays (MBBAs) exhibit lower LODs, enhanced sensitivity as well as shorter time of analysis than the respective ELISAs and can be integrated into an immunosensor with electrochemical detection on a microfluidic chip.