Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (105)
- Beitrag zu einem Tagungsband (29)
- Beitrag zu einem Sammelband (15)
- Sonstiges (10)
- Posterpräsentation (2)
- Buchkapitel (1)
- Vortrag (1)
- Preprint (1)
- Forschungsbericht (1)
Sprache
- Englisch (135)
- Deutsch (29)
- Mehrsprachig (1)
Schlagworte
- Synchrotron (13)
- XRF (12)
- Gel-type electrolytes (9)
- BAMline (8)
- Gold (8)
- Gelartige Elektrolyte (7)
- Archaeometry (6)
- Synchrotron radiation (6)
- Zinc coatings (6)
- Color X-ray camera (5)
Organisationseinheit der BAM
- 6 Materialchemie (15)
- 1 Analytische Chemie; Referenzmaterialien (14)
- 6.3 Strukturanalytik (12)
- 7 Bauwerkssicherheit (12)
- 1.4 Prozessanalytik (7)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (7)
- 2 Prozess- und Anlagensicherheit (6)
- 2.1 Sicherheit von Energieträgern (6)
- 1.5 Proteinanalytik (5)
- 4 Material und Umwelt (5)
- 8 Zerstörungsfreie Prüfung (4)
- 7.6 Korrosion und Korrosionsschutz (3)
- 4.2 Material-Mikrobiom Wechselwirkungen (2)
- 6.0 Abteilungsleitung und andere (2)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 7.4 Baustofftechnologie (2)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 1.2 Biophotonik (1)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 1.8 Umweltanalytik (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.3 Sicherheit von Transportbehältern (1)
- 4.0 Abteilungsleitung und andere (1)
- 4.3 Schadstofftransfer und Umwelttechnologien (1)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (1)
- 4.5 Kunst- und Kulturgutanalyse (1)
- 5 Werkstofftechnik (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (1)
A core component of energy storage systems like vanadium redox flow batteries (VRFB) is the polymer electrolyte membrane (PEM). In this work, the frequently used perfluorosulfonic-acid (PFSA) membrane Nafion™ 117 and a novel poly (vinylidene difluoride) (PVDF)-based Membrane are investigated. A well-known problem in VRFBs is the vanadium permeation through the membrane. The consequence of this so-called vanadium crossover is a severe loss of capacity. For a
better understanding of vanadium transport in membranes, the uptake of vanadium ions from electrolytes containing Vdimer(IV–V) and for comparison also V(II), V(III), V(IV), and V(V) by both membranes was studied. UV/VIS spectroscopy, X-ray absorption near edge structure spectroscopy (XANES), total reflection X-ray fluorescence spectroscopy (TXRF), inductively coupled plasma optical emission spectrometry (ICP-OES), and micro X-ray fluorescence spectroscopy (microXRF) were used to determine the vanadium concentrations and the species inside the membrane. The results strongly support that Vdimer(IV–V), a dimer formed from V(IV) and V(V), enters the nanoscopic water-body of Nafion™ 117 as such. This is interesting, because as of now, only the individual ions V(IV) and V(V) were considered to be transported through the membrane. Additionally, it was found that the Vdimer(IV–V) dimer partly dissociates to the individual ions in the novel PVDF-based membrane.
The Vdimer(IV–V) dimer concentration in Nafion™ was determined and compared to those of the other species. After three days of equilibration time, the concentration of the dimer is the lowest compared to the monomeric vanadium species. The concentration of vanadium in terms of the relative uptake λ = n(V)/n(SO3
) are as follows: V(II) [λ = 0.155] > V(III) [λ = 0.137] > V(IV) [λ = 0.124] > V(V) [λ = 0.053] > Vdimer(IV–V) [λ = 0.039]. The results show that the Vdimer(IV–V) dimer Needs to be considered in addition to the other monomeric species to properly describe the transport of vanadium through Nafion™ in VRFBs.
Die naturwissenschaftliche Analyse historischer Materialen ermöglicht die Beantwortung kulturhistorischer Fragestellungen, die mit kunsthistorischen oder archäologischen Ansätzen allein nicht zu leisten sind. In dieser Studie wurden sechs römische Münzen mit unterschiedlich stark ausgeprägten Korrosionsschichten an unbehandelten und polierten Stellen mit vier zerstörungsfreien analytischen Methoden untersucht: Hoch- und Niederenergie Protonen Induzierter Röntgenemission (HE-/PIXE), Synchrotronstrahlungsinduzierte-Röntgenfluoreszenzanalyse (SY-RFA) und Mikro-Röntgenfluoreszenzanalyse (Mikro-RFA) mit einem mobilen Gerät. Aufgrund von Unterschieden in den Messbedingungen und dem Einfluss der Patina-Schichten auf diese ergaben sich nur für wenige Elemente Übereinstimmungen in den quantitativen Daten. Zur Validierung zukünftiger Messkampagnen mit verschiedenen Methoden sind daher Vergleichstudien unerlässlich.
Weltweit werden etwa 80–85 % aller abgebauten Rohphosphate für die Produktion von Düngemitteln verwendet. Bei noch steigendem Bedarf an Phosphor (P) geht man derzeit davon aus, dass die weltweiten P-Reserven noch über 200 Jahre ausreichen. Um den P-Vorrat langfristig abzusichern, sollte der in Reststoffen enthaltene Phosphor möglichst umfänglich genutzt werden. Dieser Forderung trägt das von der Bundesregierung 2012 erstmals beschlossene Deutsche Ressourceneffizienzprogramm ProgRess Rechnung. Rohphosphat wird auch seitens der Europäischen Kommission aufgrundseiner ökonomischen Bedeutung und des unsicheren Angebots als „kritischer Rohstoff“ eingestuft. Vor diesem Hintergrund hat die Bundesregierung in der Verordnung zur Neuordnung der Klärschlammverwertung vom 27. September 2017 in Deutschland eine verpflichtende technische Rückgewinnung von Phosphor für Abwasserbehandlungsanlagen ab einer Ausbaugröße von 100.000 Einwohnerwerten (12 Jahre nach Inkrafttreten der Verordnung) bzw. ab einer Ausbaugröße von über 50.000 Einwohnerwerten (15 Jahre nach Inkrafttreten der Verordnung) vorgeschrieben. Die Verordnung enthält keine Vorgaben hinsichtlich der anzuwendenden Technologie bei der Phosphorrückgewinnung. Ausgenommen von der Rückgewinnungspflicht sind Klärschlämme mit niedrigen Phosphorgehalten (weniger als 20 Gramm Phosphor je Kilogramm Klärschlamm-Trockenmasse). Auch die im Jahre 2017 verabschiedeten neuen Rechtsvorschriften für die Düngung verlangen zukünftig einen nachhaltigen und ressourceneffizienten Umgang mit Nährstoffen bei der landwirtschaftlichen Erzeugung und schränken die P-Zufuhr insbesondere auf hoch versorgten Böden ein (Düngeverordnung vom 26. Mai 2017). Dies wird zu einem mehr am Pflanzenbedarf orientierten und ggf. vermehrt überbetrieblichen Einsatz von wirtschaftseigenen Düngern führen. Um den politischen und gesetzlichen Anforderungen gerecht zu werden, müssen einerseits wirksame und kosteneffiziente technische Verfahren zum P-Recycling (weiter)entwickelt werden. Andererseits müssen die Recyclingprodukte die Anforderungen für eine direkte Verwendung in der Landwirtschaft oder als Rohstoff für die Herstellung von Düngemitteln erfüllen. In dem vorliegenden Standpunkt wird zunächst der potenzielle Beitrag von Reststoffen zur Deckung des P-Bedarfs in der deutschen Pflanzenproduktion geschätzt. Für die wichtigsten Reststoffe werden technische Verfahren zur P-Rückgewinnung bzw. Aufarbeitung skizziert. Auf Basis der Anforderungen der Landwirtschaft bzw. der Düngemittelindustrie
an die P-Recyclingprodukte werden deren Herstellungsverfahren bewertet. Schließlich wird der Regelungs- und Forschungsbedarf formuliert.
Results of a round-robin experiment in multiple-pulse LIDT measurement with ultrashort pulses
(2004)
Textile, aluminium and polyethylene used as components in laser protection curtains were investigated with respect to their ablation behaviour. Employing 33-fs pulses (800 nm wavelength, 1 kHz repetition rate), ex situ geometrical measurements of the ablation cavities and in situ acoustic investigations with a microphone were performed to determine the ablation thresholds in the single- and multi-pulse cases. The acoustical method proved advantageous for complex surface morphologies and/or single laser pulse interactions. Incubation phenomena can be observed for all the materials studied. Technically relevant multi-pulse ablation thresholds are presented and are compared with the single-pulse (1-on-1) irradiation.
Methane dry reforming (DRM) was investigated over highly active Ni catalysts with low metal content (2.5wt%) supported on Mg-Al mixed oxide. The aim was to minimize carbon Deposition and metal sites agglomeration on the working catalyst which are known to cause catalyst deactivation.
The solids were characterized using N2 adsorption, X-ray diffraction, temperature-programmed reduction, X-ray photoelectron spectroscopy, and UV-Vis diffuse reflectance spectroscopy. The results showed that MgO-Al2O3 solid solution phases are obtained when calcining Mg-Al hydrotalcite precursor in the temperature range of 550–800 °C. Such phases contribute to the high activity of catalysts with low Ni content even at low temperature (500 °C). Modifying the catalyst preparation with citric acid significantly slows the coking rate and reduces the size of large octahedrally coordinated NiO-like domains, which may easily agglomerate on the surface during DRM. The most effective Ni catalyst shows a stable DRM course over 60 h at high weight hourly space velocity with very low coke deposition. This is a promising result for considering such catalyst systems for further development of an industrial DRM technology.
The injection of hydrogen into the natural-gas grid is an alternative during the process of a gradual decarbonization of the heat and power supply. When dealing with hydrogen-enriched natural gas mixtures, the performance of the reference equations of state habitually used for natural gas should be validated by using high-precision experimental thermophysical data from multicomponent reference mixtures prepared with the lowest possible uncertainty in composition. In this work, we present experimental density data for an 11-compound high-calorific (hydrogen-free) natural gas mixture and for two derived hydrogen-enriched natural gas mixtures prepared by adding (10 and 20) mol-% of hydrogen to the original standard natural gas mixture. The three mixtures were prepared gravimetrically according to ISO 6142–1 for maximum precision in their composition and thus qualify for reference materials. A single-sinker densimeter was used to determine the density of the mixtures from (250–350) K and up to 20 MPa. The experimental density results of this work have been compared to the densities calculated by three different reference equations of state for natural gas related mixtures: the AGA8-DC92 EoS, the GERG-2008 EoS, and an improved version of the GERG-2008 EoS. While relative deviations of the experimental density data for the hydrogen-free natural gas mixture are always within the claimed uncertainty of the three considered equations of state, larger deviations can be observed for the hydrogen-enriched natural gas mixtures from any of the three equations of state, especially for the lowest temperature and the highest pressures.
Several glazed ceramic fragments (XVIth to XVIIIth centuries) from two production centers in Portugal (Coimbra and Lisbon) were the object of this study. The ones from Coimbra comprise two sets of samples: faiences and tiles. The ones from Lisbon are only tiles (azulejos, in Portuguese). The three main divisions of such pieces are the ceramic support (body), glaze and surface decoration. The system decoration/glaze is not easy to investigate, due to the high heterogeneity resulting from the mixing procedures and firing temperatures used. Moreover, the ability of the pigment to diffuse into the base glaze varies depending on the composition of both the pigment and the glaze in terms of fusibility. In order to raster these effects, high resolution techniques are required. In this work, synchrotron micro-X-ray fluorescence (µ-XRF) analysis was performed to monitor the profiles of the characteristic elements from the colors used and the glaze in well prepared cross-sections of the samples. Key elements are: Co for blue, Mn for purple, Cu for green, Sb for yellow, Pb for the glaze and Fe for the body. The major difference observed is that faiences have glaze thicknesses between 150 and 200 µm and tiles have glaze thicknesses between 350 and 400 µm. Furthermore, in faiences all the pigments except the yellow ones are well dispersed into the glassy matrix, while in tiles, all of them are just partially diffused throughout the glaze. However, differences between the tiles from Coimbra and Lisbon were observed. In the samples from Lisbon, a higher intake from the pigment throughout the glaze is observed.
In this study the microscopic homogeneity of the newly developed plastic reference materials BAM H001-BAM H010 was investigated. The materials consist of an acrylonitryle-butadien-styrene terpolymer, doped with different amounts of the elements Br, Cd, Cr, Hg and Pb. For the quantitative determination of the degree of homogeneity, a procedure proposed by Kempenaers et al. (Fresenius J. Anal. Chem., 2001, 369, 733-737) was used. On every sample an extensive number of different points were analyzed and standard deviation for every element mentioned above was used to calculate a minimal sampling mass that is necessary to reach a certain level of uncertainty caused by inhomogeneity (mmin,5%). The experiments were taken out with synchrotron µ-XRF (SR µ-XRF) at BESSYII in Berlin and by laser ablation inductively coupled plasma mass spectroscopy (LA-ICP-MS). The calculated values for mmin,5% of both techniques showed comparable results for all elements. It could be shown that the materials are suitable for calibration of micro analytic techniques if at least 64 µg are used.
Measurements of ion distributions at a charged solid–liquid interface using X-ray standing waves (XSW) are presented. High energy synchrotron radiation (17.48 keV) is used to produce an XSW pattern inside a thin water film on a silicon wafer. The liquid phase is an aqueous solution containing Br and Rb ions. The surface charge is adjusted by titration. Measurements are performed over a pH range from 2.2–9, using the native Si oxide layer and functional (amine) groups as surface charge. The Debye length, indicating the extension of the diffuse layer, could be measured with values varying between 1–4 nm. For functionalized wafers, the pH dependent change from attraction to repulsion of an ion species could be detected, indicating the isoelectric point. In combination with the measurement of the streaming current, the surface charge of the sample could be quantified.
This study intends to clarify the metal provenance of gold archaeological items using the variation of the Au–Ag ratio and the presence of trace elements as Sn, Sb, Te, and Pb, concentrating on gold Dacian Koson coins, recovered recently. It also extends the area of our investigations to the copper provenance of Bronze Age artifacts—axes, sickles, and celts—found on Romanian territory. The experiments were performed by micro-SR XRF at BESSY Berlin, at the BAM-line facility. Two types of coins (Koson, with and without monogram) were analysed. The conclusions we reached were that most of the monogram coins are made from refined gold (3–5% Ag, less than 0.5% Cu), while the without monogram coins are made from native Transylvanian gold (9–20% Ag, 0.5–2% Cu), of alluvial origin, proved by the presence of Sn, Sb and Te embedded in the gold. The problem of provenance for prehistoric Romanian copper and bronze objects consists in linking their elemental compositional patterns to the ones of the Bronze Age regional mines from Bulgaria, Serbia or Transylvania, most likely used as ore sources for their manufacture. The studied samples present relevant traces of As, Ag, Sb, and Co, suggesting the most probable use of copper from Serbia or northern Bulgaria for their manufacture.
Synchrotron radiation (SR) has been used in recent years as an excellent excitation source for X-ray fluorescence spectrometry. SR offers, in contrast to conventional X-ray sources, highly brilliant polychromatic, polarized radiation with which micro-domain X-ray fluorescence spectrometry becomes possible. A feasibility study of utility, conducted at BESSY (Berlin) and at DELTA (Dortmund), both synchrotron facilities of the third generation, to evaluate the use of wavelength dispersive X-ray fluorescence spectrometry in combination with synchrotron radiation is presented. First results for material analysis, obtained by combining the synchrotron radiation and a commercially available spectrometer commonly attached to a scanning electron microscope, are presented. The spectrometer, of the linear type, uses curved focusing Bragg-crystals of the Johann type which leads to a high spectral resolution up to 3 eV. Examples of micro-domain analyses are presented and compared with those obtained by synchrotron radiation induced energy dispersive X-ray fluorescence.
Pilot studies have been carried out at the BAMline at BESSY II in collaboration with the Bundesanstalt
für Materialforschung und -prüfung (BAM) on metal- and metalloid-containing compounds in biological
samples after electrophoretic protein separation. After sodium dodecylsulfate polyacrylamide gel
electrophoresis (SDS-PAGE) and transfer onto a blotting membrane the distribution of selenium among
the proteins of testis homogenate of a rat and a wallaby was determined. The comparison with the
autoradiogram of 75Se-labeled proteins separated in the same way showed that of nine seleniumcontaining
proteins found in rat testis homogenate by autoradiography four could be detected by
synchrotron radiation X-ray fluorescence analysis (SRXRF).
Naturwissenschaftler arbeiten mit Archäologen, Kunsthistorikern und Restauratoren zusammen, um Materialinformationen über Kunstwerke mit den Erkenntnissen aus Altertumsforschung, Kunstgeschichte und Denkmalpflege zu verbinden. Röntgenfluoreszenz und Röntgenemission sind die Methoden der Wahl, wenn wertvolle und fragile Objekte zerstörungsfrei zu untersuchen sind.
3D micro X-ray fluorescence spectroscopy - combining elemental analysis with chemical speciation
(2004)
The propagation of synchrotron radiation through nanocapillary structures with channel sizes of 200 nm and periods in the micrometer size has been studied experimentally. It was shown that the propagation through individual capillary channels has a mode formation character. Furthermore it was shown that during the propagation through capillary channels the coherence of synchrotron radiation is partially conserved. Interference of beams propagating through different capillary channels is observed which leads to a periodically modulated distribution of the radiation intensity in a plane far from the exit of the structure. These investigations are of high relevance for the understanding of X-ray transmission through nanocapillaries and the appearance of wave properties at this size scale.
Ein Konvolut einzelner Schmuckstücke und die Goldbeigaben eines angeblichen Grabfundes wurden technologisch und analytisch untersucht. Die meisten Objekte sind Blecharbeiten, die aus einer Vielzahl von Einzelteilen mit metallischem Goldlot zusammengefügt und mit Granulation oder granulations-imitierendem Perl- oder Kerbdraht verziert wurden. Nur vier kleine Ohrringe sind massiv gegossen.
Zwei Zierbleche dürften über Patrizen (Positivmodeln), die Deckel der Astragale in Matrizen (Negativmodeln) geformt worden sein. Alle Objekte wurden mit Synchrotron- und atmosphärischer Röntgenfluoreszenz analysiert. Die Daten zeigen das breite Spektrum an Goldlegierungen, die im 7./6. Jahrhundert v. Chr. in Kleinasien verarbeitet wurden: vom natürlichen Seifengold (Elektrum) bis zu geläutertem, fast reinem Gold. Eine Korrelation zwischen Goldqualität und Verarbeitungsmethode konnte nicht festgestellt werden. Sowohl hochreines als auch mit viel Silber und Kupfer legiertes Gold wurde zum Schmieden von Blecharbeiten, aber auch zum Massivguss verwendet. Aus der Goldfarbe kann wegen des Phänomens der oberflächlichen Goldanreicherung nicht auf eine Legierungszusammensetzung geschlossen werden. Der 1963 angekaufte Fundkomplex aus lydischen Metallarbeiten und ostionischen Salbgefäßen aus Ton dürfte einen Grabfund des frühen 6. Jahrhunderts v. Chr. darstellen, dessen Herkunft aus Ephesos jedoch nicht zu sichern ist.
Naturwissenschaftliche Informationen, insbesondere die chemische Zusammensetzung der Objekte, können Hinweise auf die Hintergründe der Objektherstellung liefern, die der alleinigen kunsthistorischen Begutachtung verborgen blieben. Es können nicht nur Fragen nach dem Prozess, Zeitpunkt und Ort der Herstellung beantwortet werden. Die chemische Analyse gibt auch Hinweise auf Ereignisse und Veränderungen, die erst nach der Fertigstellung des Objektes erfolgten. So werden Alterungsphänomene oder historische Überarbeitungen und Restaurierungen aufgedeckt, aber auch Konservierungsstrategien zur Erhaltung der Kunstwerke unterstützt. Durch den technologischen Fortschritt im Bereich der röntgenanalytischen Methoden, die berührungsfrei, ohne Probennahme und ohne Schädigung für das Untersuchungsobjekt arbeiten, erschließen sich dem Analytiker erstmalig Möglichkeiten, auch sehr wertvolle und fragile Objekte zerstörungsfrei zu untersuchen.
This paper is an overview of the work developed by our group in the investigations of museum objects and alluvial gold, reflected in a series of studies published between 2000–2011, supplemented with new results, unpublished up-to-date. The X-ray based spectrometric techniques employed range from various X-Ray Fluorescence (XRF) investigations to ion beam analysis, including synchrotron radiation XRF and micro-Particle Induced X-ray Emission. The gold objects discussed are mainly part of the Sarmizegetusa Dacian hoards—spiraled bracelets (armbands) and coins. After obtaining in 2011 the permission of the Romanian authorities to take very small (1–2 mg) samples from the most 'unimportant' areas of the Dacian bracelets and several Koson staters, to analyze them by micro-SR-XRF at BESSY, in February 2012, the investigation of several micro-areas of 17 stater and 28 bracelet samples revealed important micro-structural inhomogeneity, especially in Sn and Cu. The same inhomogeneous micro-structure has been seen in Transylvanian alluvial gold. The analyses revealed details on the fingerprint of geological gold deposits and also the main characteristics of ancient gold metallurgy procedures used by the Dacians: a relatively low temperature (lower than Au melting point) and hammering during heating to obtain an ingot through sintering. The use of the sintering procedure was proved for the spiraled bracelets and the Koson without monogram coins, a tradition starting in the Bronze Age in Transylvanian gold processing. The existence of micro-inclusions of Ta-minerals in alluvial gold was also detected, explaining Ta trace presence in the artifacts from the Pietroasa hoard.
This work presents a complex evaluation of a series of Geto-Thracian silver adornments found on Romanian territory, part of the 4th century BC Agighiol (Northern Dobruja) hoard and of an ingot from the 1st century BC Geto-Dacian Surcea (Transylvania) hoard, using Synchrotron Radiation X-Ray Fluorescence and micro- Proton Induced X-ray Emission analysis and mapping in order to investigate aspects related to the elemental composition of the metal and the metallurgy implied in their manufacture. One of the samples can be linked to Laurion as the source of metal, and several items contain silver probably originated in Macedonia. The set of silver items was found to be heteregenous as composition and microstructure, and corrosion-related elements could be also identified in the X-Ray maps.
The conventional hybridoma screening and subcloning process is generally considered to be one of the most critical steps in hapten-specific antibody production. It is time-consuming, monoclonality is not guaranteed, and the number of clones that can be screened is limited. Our approach employs a novel hapten-specific labeling technique of hybridoma cells. This allows for fluorescence-activated cell sorting (FACS) and single-cell deposition and thereby eliminates the above-mentioned problems. A two-step staining approach is used to detect antigen specificity and antibody expression: in order to detect antigen specificity, hybridoma cells are incubated with a hapten−horseradish peroxidase conjugate (hapten−HRP), which is subsequently incubated with a fluorophore-labeled polyclonal anti-peroxidase antibody (anti-HRP−Alexa Fluor 488). To characterize the expression of membrane-bound immunoglobulin G (IgG), a fluorophore-labeled anti-mouse IgG antibody (anti-IgG−Alexa Fluor 647) is used. Hundreds of labeled hybridoma cells producing monoclonal antibodies (mAbs) specific for a hapten were rapidly isolated and deposited from a fusion mixture as single-cell clones via FACS. Enzyme-linked immunosorbent assay (ELISA) measurements of the supernatants of the sorted hybridoma clones revealed that all hapten-specific hybridoma clones secrete antibodies against the target. There are significant improvements using this high-throughput technique for the generation of mAbs including increased yield of antibody-producing hybridoma clones, ensured monoclonality of sorted cells, and reduced development times.
Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial,we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules. After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing.
Inelastic incoherent neutron time-of-flight scattering was employed to investigate the low-frequency vibrational density of states (VDOSs) for a series of glassy Janus-poly(tricyclononenes), which consist of a rigid main chain and flexible alkyl side chains. Here, the length of the flexible side chains was systematically varied from propyl to octyl. Such materials have potential applications as active separation layers in gas separation membranes as a green future technology, especially for the separation of higher hydrocarbons. From the morphological point of view, the Janus polynorbornenes undergo a nanophase separation into alkyl side chain-rich nanodomains surrounded by a rigid polynorbornene matrix. Here, the influence of the nanophase-separated structure on the low-frequency VDOS is investigated from a fundamental point of view. The low-frequency VDOSs of these Janus polynorbornene show excess contributions to the Debye type VDOS known as the Boson peak (BP) for all side chain lengths. Due to the high incoherent scattering cross-section of hydrogen, most of the scattering comes from the alkyl side chain-rich domains.
Compared to conventional glass-forming materials, in the considered Janus polynorbornenes, the BP has a much lower intensity and its frequency position is shifted to higher values. These experimental results are discussed in terms of the nanophase-separated structure where the alkyl chain-rich domains were constrained by the surrounding matrix dominated by the rigid backbone. With increasing alkyl chain length, the size of the alkyl chain-rich domains increases. The frequency position of the BP shifts linearly to lower frequencies with the size of these nanodomains estimated from X-ray measurements. The obtained results support the sound wave interpretation to the BP
In this study, we propose the use of nondestructive, depth-resolved, element-specific characterization using grazing exit X-ray absorption near-edge structure spectroscopy (GE-XANES) to investigate the corrosion process in compositionally complex alloys (CCAs). By combining grazing exit X-ray fluorescence spectroscopy (GE-XRF) geometry and a pnCCD detector, we provide a scanning-free, nondestructive, depth-resolved analysis in a sub-micrometer depth range, which is especially relevant for layered materials, such as corroded CCAs. Our setup allows for spatial and energy-resolved measurements and directly extracts the desired fluorescence line, free from scattering events and other overlapping lines. We demonstrate the potential of our approach on a compositionally complex CrCoNi alloy and a layered reference sample with known composition and specific layer thickness. Our findings indicate that this new GE-XANES approach has exciting opportunities for studying surface catalysis and corrosion processes in real-world materials.
A collaborative trial involving 16 participants from nine European countries was conducted within the NORMAN network in efforts to harmonise suspect and non-target screening of environmental contaminants in whole fish samples of bream (Abramis brama). Participants were provided with freeze-dried, homogenised fish samples from a contaminated and a reference site, extracts (spiked and non-spiked) and reference sample preparation protocols for liquid chromatography (LC) and gas chromatography (GC) coupled to high resolution mass spectrometry (HRMS). Participants extracted fish samples using their in-house sample preparation method and/or the protocol provided. Participants correctly identified 9-69% of spiked compounds using LC-HRMS and 20-60% of spiked compounds using GC-HRMS. From the contaminated site, suspect screening with participants’ own suspect lists led to putative identification of on average ~145 and ~20 unique features per participant using LC-HRMS and GC-HRMS, respectively, while non-target screening identified on average ~42 and ~56 unique features per participant using LC-HRMS and GC-HRMS, respectively. Within the same sub-group of sample preparation method, only a few features were identified by at least two participants in suspect screening (16 features using LC-HRMS, 0 features using GC-HRMS) and non-target screening (0 features using LC-HRMS, 2 features using GC-HRMS). The compounds identified had log octanol/water partition coefficient (KOW) values ranging from -9.9 to 16 and mass-to-charge ratio (m/z) of 68 to 761 (LC-HRMS and GC-HRMS). A significant linear trend was found between log KOW and m/z for the GC-HRMS data. Overall, these findings indicate that differences in screening results are mainly due to the data analysis workflows used by different participants. Further work is needed to harmonise the results obtained when applying suspect and non-target screening approaches to environmental biota samples.
DICONDE (Digital Imaging and Communication in Non-Destructive Testing) is an open international standard for storing and exchanging industrial test data and process-related information. The DICONDE standard defines both the semantics for structured storage of data and the network-based communication between two endpoints. This allows many test processes to be mapped digitally and securely, while at the same time meeting normative requirements such as traceability to the tester and test object and reproducibility of test results.
DICONDE in der ZfP
(2023)
DICONDE (Digital Imaging and Communication in Non-Destructive Evaluation) ist ein offener internationaler Standard zur Speicherung und zum Austausch industrieller Prüfdaten und prozessbezogener Informationen. Der DICONDE-Standard definiert sowohl die Semantik für eine strukturierte Speicherung von Daten als auch die netzwerkbasierte Kommunikation zwischen zwei Endpunkten. Damit lassen sich viele Vorgänge von Prüfprozessen digital und sicher abbilden und gleichzeitig normative Anforderungen wie eine Rückführbarkeit zum Prüfer und Prüfobjekt sowie eine Reproduzierbarkeit von Prüfergebnissen erfüllen.
n this study, two green synthesis routes were used for the synthesis of Ag/ZnO nanoparticles, using cassava starch as a simple and low-cost effective fuel and Aloe vera as a reducing and stabilizing agent. The Ag/ZnO nanoparticles were characterized and used for bacterial dis-
infection of lake water contaminated with Escherichia coli (E. coli). Characterization indicated the formation of a face-centered cubic structure of metallic silver nanoparticles with no insertion of Ag into the ZnO hexagonal wurtzite structure. Physicochemical and bacteriological analyses described in “Standard Methods for the Examination of Water and Wastewater” were used to evaluate the efficiency of the treatment. In comparison to pure ZnO, the synthesized Ag/ZnO nanoparticles showed high efficiencies against Escherichia coli (E. coli) and general coliforms present in the lake
water. These pathogens were absent after treatment using Ag/ZnO nanoparticles. The results indicate that Ag/ZnO nanoparticles synthesized via green chemistry are a promising candidate for the treatment of wastewaters contaminated by bacteria, due to their facile preparation, low-cost synthesis,and disinfection efficiency.
This work reports new experimental data on densities and viscosities of (CO2 + n-pentane) and (CO2 + n-hexane) mixtures at high pressures and temperatures. The densities were measured by a vibrating-tube densimeter with an expanded uncertainty (k = 2) smaller than 1.8 kg/m3 at six isotherms (from 273.15 K to 373.15 K), twelve pressures starting at 5 MPa up to 100 MPa, and at six CO2 molar compositions (from 0 to 0.6). The viscosities were measured by a vibrating-wire viscometer with the corresponding relative expanded uncertainty (k = 2) smaller than 0.016 at five isotherms (from 273.15 K to 373.15 K), twelve pressures (from 5 MPa up to 100 MPa), and at two CO2 molar compositions (0.1 and 0.3). The densities were fitted by the semiempirical Tammann-Tait equation for density data and the Vogel-Fulcher-Tammann (VFT) equation for viscosity data, respectively. The Groupe Européen de Recherches Gazières (GERG-2008) equation of state was also applied for modelling the densities. Over-all robustness and reliability of the Perturbed-Chain Statistical Association Fluid Theory (PC-SAFT) and its critical point-based modification (CP-PC-SAFT) were examined. Accuracies of the Modified Yarranton-Satyro (MYS) coupled with CP-PC-SAFT and the NIST Reference Fluid Thermodynamic and Transport Properties Database (REFPROP 10) in predicting the viscosities were evaluated.
Rigid polyurethane foams (RPUFs) exhibit short times to ignition as well as rapid flame spread and are therefore considered to be hazardous materials. This paper focuses on the fire phenomena of RPUFs, which were investigated through a multimethodological approach. Water-blown polyurethane (PUR) foams without flame retardants (FRs) as well as waterblown PUR foams containing triethyl phosphate as a gas phase-active FR were examined. The aim of this study is to clarify the influence of the FR on the fire phenomena during combustion of the foams. Additionally, materials’ densitieswere varied to range from 30 to 100 kg/m3. Thermophysical properties were studied bymeans of thermogravimetry; fire behavior and flammability were investigated via cone calorimeter and limiting Oxygen index, respectively. During the cone calorimeter test, the temperature development inside the burning specimens was monitored with thermocouples, and cross sections of quenched specimens were examined visually, giving insight into the morphological changes during combustion.
The present paper delivers a comprehensive study, illuminating phenomena occurring during foam combustion and the influence of a FR active in the gas phase. The superior fire performance of flameretarded PUR foams was found to be based on flame inhibition, and on increased char yield leading to a more effective protective layer. It was proven that in-depth absorption of radiation is a significant factor for estimation of time to ignition. Cross sections investigated with the electron scanning microscope exhibited a pyrolysis front with an intact foam structure underneath. The measurement of temperature development inside burning specimens implied a shift of burning behavior towards that of non-cellular materials with rising foam density.
Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial, we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules.
After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing.
X-ray absorption spectroscopy (XAS) provides a unique, atom-specific tool to probe the electronic structure of solids. By surmounting long-held limitations of powder-based XAS using a dynamically averaged powder in a Resonant Acoustic Mixer (RAM), we demonstrate how time-resolved in situ (TRIS) XAS provides unprecedented detail of mechanochemical synthesis. The use of a custom-designed dispersive XAS (DXAS) setup allows us to increase the time resolution over existing fluorescence measurements from ∼15 min to 2 s for a complete absorption spectrum. Hence, we here establish TRIS-XAS as a viable method for studying mechanochemical reactions and sampling reaction kinetics. The generality of our approach is demonstrated through RAM-induced (i) bottom-up Au nanoparticle mechanosynthesis and (ii) the synthesis of a prototypical metal organic framework, ZIF-8. Moreover, we demonstrate that our approach also works with the addition of a stainless steel milling ball, opening the door to using TRIS-DXAS for following conventional ball milling reactions. We expect that our TRIS-DXAS approach will become an essential part of the mechanochemical tool box.
The impact of phosphorus-containing flame retardants (FR) on rigid polyisocyanurate (PIR) foams is studied by systematic variation of the chemical structure of the FR, including non-NCO-reactive and NCO-reactive dibenzo[d,f][1,3,2]dioxaphosphepine 6-oxide (BPPO)- and 9,10 dihydro-9-oxa-10 phosphaphenanthrene-10-oxide (DOPO)-containing compounds, among them a number of compounds not reported so far. These PIR foams are compared with PIR foams without FR and with standard FRs with respect to foam properties, thermal decomposition, and fire behavior. Although BPPO and DOPO differ by just one oxygen atom, the impact on the FR properties is very significant: when the FR is a filler or a dangling (dead) end in the PIR polymer network, DOPO is more effective than BPPO. When the FR is a subunit of a diol and it is fully incorporated in the PIR network, BPPO delivers superior results.
The limited availability of accurate experimental data in wide ranges of pressure, temperature, and composition is the main constraining factor for the proper development and assessment of thermodynamic models and equations of state. In the particular case of carbon capture and storage (CCS) processes, there is a clear need for data sets related to the (carbon dioxide + oxygen) mixtures that this work aims to address. This work provides new experimental (p, rho, T) data for three binary (CO2 + O2) mixtures with mole fractions of oxygen x(O2) = (0.05, 0.10, and 0.20) mol/mol, in the temperature range T = (250 to 375) K and pressure range p = (0.5 to 13) MPa. The measurements were performed with a high-precision single-sinker densimeter with magnetic suspension coupling. The density data were obtained with estimated expanded relative uncertainties of 0.02 % for the highest densities and up to 0.3 % for the lowest ones.The results were compared to the corresponding results calculated by the current reference equations of state for this kind of mixtures, namely the EOS-CG (combustion gases) and the GERG-2008 equation of state, respectively. The EOS-CG yields better estimations in density than the GERG-2008 equation of state. The results from the EOS-GC model show no systematic temperature dependence. For the GERG-2008 model, however, this criterion is significantly less fulfilled.
In diesem Verbundvorhaben werden standardisierte Messverfahren für hybride Gemische erarbeitet, die der Bestimmung sicherheitstechnischer Kenngrößen des Explosionsschutzes dienen. Unter einem hybriden Gemisch wird dabei ein mehrphasiges System aus Brenngas oder brennbarem Dampf, sowie Luft und brennbarem Staub verstanden. Die Veröffentlichung der Ergebnisse erfolgt in einem Abschlussbericht und als DIN-Spezifikation (DIN SPEC). Diese DIN SPEC versetzt Prüfinstitute und Industrie in die Lage, Explosionsgefahren beim Betrieb technischer Anlagen mit hybriden Gemischen einzuschätzen und damit Prozesse sowohl sicherer als auch effizienter zu steuern. Dieses Projekt wird im Rahmen des WIPANOProgramms (Wissens- und Technologietransfer durch Patente und Normen) vom BMWi gefördert.
The development of traceable new methodologies to quantify elemental air pollutants in particulate matter (PM) supports modernization of methods used in air quality monitoring networks in Europe. In the framework of the EURAMET EMPIR AEROMET II project, the combination of cascade impactor aerosol sampling and total reflection X-ray fluorescence elemental spectroscopy (TXRF) was investigated. This technique requires a traceable calibration based on reference samples. This paper describes a new, simple and effective method to produce such reference samples using flexible, reusable, and low-cost parylene C shadow masks, fabricated by photolithographic steps. These shadow masks can be used to produce reference samples that mimic the Dekati cascade impactor’s deposition patterns by applying as-prepared micro stencils to 30 mm acrylic substrates and evaporating a reference material (Ti) in arrangements of thin circular dots. The highly flexible direct patterning of acrylic discs with reference material, otherwise impossible with conventional photolithography, allows multiple reusing of the same micro stencils. The aspect ratios of the dots could be repeated with an error less than 4 %. A first set of standard reference samples for the 13 stages of the Dekati cascade impactor was produced and preliminary TXRF measurements of the deposited Ti masses were performed. The centricity of the deposition patterns turned out to be an important parameter for the quality of the TXRF results. The parylene mask technology for the production of reference samples turns out to be a promising new approach for the traceable calibration of TXRF spectrometers for the quantification of element concentrations in environmental aerosol samples but, due to its great versatility, it could be used for several other micropatterning applications on conventional and unconventional substrates.
On the way to a low carbon economy mixtures containing carbon dioxide become increasingly important. Processing of such gas mixtures requires reliable thermodynamic models that can accurately describe the state of matter over an extended range. Mixtures with oxygen for example, are frequently encountered in carbon capture and storage (CCS) processes.
This work reports new experimental (p, rho, T) data at T = (250 to 375 K) and up to a maximum pressure pmax = 20 MPa for five binary (CO2 + O2) mixtures which cover the entire composition range.
Gaseous inhibitors are used in many industries for the explosion prevention of combustible dusts, mitigating the potential hazard to humans, properties and environments. This work experimentally and theoretically studied the inerting effect of gaseous inhibitors on the ignition process of dust clouds in O2/N2/CO2 atmospheres, with an emphasis on the role of the CO2/N2 ratio. 10 different combustible carbonaceous dusts were selected, including grain dust, biomass dust and coal dust. Experimental results showed that the inhibition effect of CO2/N2 is closely related to the ignition mechanism of dust clouds. Specifically, a higher ratio of CO2/N2 yields a stronger inhibition effect on the ignition process of dust samples with relatively low volatile matter contents predominated by heterogeneous ignition. In addition, two novel steady-state ignition mechanism models were developed to interpret the experimental observations. Maxwell-Stefan equations were used to describe the diffusivity in the ternary O2/N2/CO2 gas mixtures. The analytical results were in good agreement with the experimental data of the minimum ignition temperature of dust cloud (MITC) in oxygen-lean atmospheres. The mechanism modelling can be used to estimate the critical ignition temperature of all carbonaceous dust clouds with a wide range of volatile matter content under different inert atmospheres, which will provide a reference for the explosion hazard assessment of dust posed by a hot surface in the process industries.
Minimum ignition temperature of dust clouds (MITC) was studied experimentally and theoretically in different atmospheres. Three carbonaceous dusts were tested in both air and O2/CO2 atmospheres with CH4 mole fraction from 0 to 2%. Results showed that the ignition risk of the three dusts significantly increases (decrease of MITC by ~100 ℃) with increasing XO2 from 21% to 50%, but significantly decreases replacing N2 in air with CO2. The inhibition effect of CO2 on MITCs could be diminished by increasing XO2 or adding CH4. The addition of small amount of CH4 has different effects on the MITCs of different dust samples, following the opposite order of volatile matter content: anthracite>bituminous coal>starch. Two modified steady-state ignition models, considering the density of mixture gas and dust cloud, XO2 and its diffusivity, were developed to interpret the experimental observations. The analysis revealed that the global heterogeneous ignition model suits well for the hybrid mixtures of anthracite or bituminous coal dusts. In contrast, the proposed global homogeneous ignition model was found to be only valid for the pure starch dust, and the extra CH4 addition could strongly affect the ignition process of starch, particularly in O2/CO2 atmospheres with higher XO2.
The Scythica Vindobonensia, the new fragments on Gothic incursions into Roman provinces in the Balkans in the middle of the third century AD that were revealed some years ago in a Greek palimpsest at the Austrian National Library in Vienna (ÖNB), are commonly considered as one of the most important additions of the last decades to the corpus of texts from classical Antiquity. Tere is a high degree of confdence among scholars in supposing that the fragments come from the lost work Scythica written in Greek by the third-century historian P. Herennius Dexippus (Δέξιππος) of Athens. The new fragments have hence also been called Dexippus Vindobonensis. In his Scythica, Dexippus recorded wars of the Romans with the Goths (and other tribes) whom he called Scythians.
The work had been hitherto known only from excerpts and quotes by later authors. Eight pages of a Byzantine manuscript copy of the ancient text have survived hidden underneath the visible surface of the last four parchment folios of the Vienna manuscript Historicus graecus 73, f. 192r -195v4. The copy is written in a Greek calligraphic minuscule which has been estimated by palaeographers to be of the middle or the second half of the eleventh century. In the thirteenth century, the text (on each of the eight pages arranged in one column, with 30 lines per page) was washed of the parchment and the valuable material made from animal skin was re-used for Christian texts. The new writing largely covered the faded remnants of the original text. It thus became hidden from the human eye for more than seven hundred years. Its discovery by Jana Grusková, a classical philologist specialized in the transmission of Greek texts, resulted from a systematic review of all Greek palimpsests kept at the Austrian National Library in Vienna at the beginning of the twenty-first century and a detailed examination of the four folios in 2007-20097.
The vanadium redox flow battery (VRFB) is currently a potential candidate for stationary energy storage. A major challenge is the unintended vanadium transport through the separator, which results in a fade of capacity. To overcome this issue, it is necessary to understand the transport processes in the membrane on a more fundamental level. In this work, the vanadium species distribution in Nafion™ 117 after cyclization was investigated. Two membranes, one from a charged VRFB and another from a discharged VRFB, were analyzed using ultraviolet–visible spectroscopy (UV/VIS) and X-ray absorption near edge structure spectroscopy (XANES). Little difference between the two membranes was recognizable according to the UV/VIS results. In comparison, the XANES results showed that the membrane from the charged VRFB contains more V3+ than VO2+, whereas for the discharged case, more VO2+ is present in the membrane.
In this study, a multi-proxy approach combining 29Si, 27Al and 1H MAS-NMR, FEG-EPMA, XANES at the Cu K-edge and XRD analytics with hydrochemical tools such as ICP-OES analyses, oxygen-isotope signatures, and thermodynamic modelling was applied to K-silicate-activated metakaolin specimens - with and without CuSO4·5H2O addition - exposed to sulfuric acid at pH = 2 for 35 days. The results revealed a multistage deterioration mechanism governed by (i) acid diffusion, (ii) leaching of K-A-S-H, (iii) microstructural damage related to precipitation of expansive (K,Ca,Al)-sulfate-hydrate phases (iv) complete dissolution of the K-A-S-H framework, (v) and formation of silica gel in the outermost corroded regions. Copper ions were mainly located in layered spertiniite-chrysocolla-like phases in the as-cured materials. The results demonstrate an overall negative effect of Cu addition on chemical material durability, implying that the reported higher durability of Cu-doped AAM in biocorrosion environments can be best explained by bacteriostatic effects.
In this work, we describe the use of artificial neural networks for the quantification of X-ray fluorescence measurements. The training data were generated using Monte Carlo simulation, which avoided the use of adapted reference materials. The extension of the available data set by means of an ANN to generate additional data was demonstrated. Particular emphasis was put on the comparability of simulated and experimental data and how the influence of deviations can be reduced. The search for the optimal hyperparameter, manual and automatic, is also described. For the presented case, we were able to train a network with a mean absolute error of 0.1 weight percent for the synthetic data and 0.7 weight percent for a set of experimental data obtained with certified reference materials.
Rigid polyurethane foams (RPUFs) typically exhibit low thermal inertia, resulting in short ignition times and rapid flame spread. In this study, the fire phenomena of RPUFs were investigated using a multi-methodological approach to gain detailed insight into the fire behaviour of pentaneand water-blown polyurethane (PUR) as well as pentane-blown polyisocyanurate Polyurethane (PIR) foams with densities ranging from 30 to 100 kg/m3. Thermophysical properties were studied using thermogravimetry (TG); flammability and fire behaviour were investigated by means of the limiting oxygen index (LOI) and a cone calorimeter. Temperature development in burning cone calorimeter specimens was monitored with thermocouples inside the foam samples and visual investigation of quenched specimens’ cross sections gave insight into the morphological changes during burning. A comprehensive investigation is presented, illuminating the processes taking place during foam combustion. Cone calorimeter tests revealed that in-depth absorption of radiation is a significant factor in estimating the time to ignition. Cross sections examined with an electron scanning microscope (SEM) revealed a pyrolysis front with an intact foam structure underneath, and temperature measurement inside burning specimens indicated that, as foam density increased, their burning behaviour shifted towards that of solid materials. The superior fire performance of PIR foams was found to be based on the cellular structure, which is retained in the residue to some extent.
Im deutschen Eisenbahnnetz sind ca. 80 Millionen Spannbetonschwellen verbaut. Analog zu anderen Bauwerken werden Wpannbetonschwellen regelmäßig visuell inspiziert. Die Rissbildung ist bei diesen Inspektionen ein Kriterium für die Schädigung einer Spannbetonschwelle. Durch Rissbildung kann es passieren, dass Betonschwellen ihre Nutzungsdauer nicht erreichen.
Electrochemical tests, hardness measurements, and microstructure analysis are performed to study the influence of austenitizing, quenching, and tempering parameters on the corrosion resistance of the martensitic stainless steel grade X50CrMoV15 (1.4116). Different heat treatment states were studied using an adapted EPR-Test to evaluate the chromium distribution and depletion caused by the formation and dissolution of chromium rich carbides. The EPR results were correlated with pitting corrosion behavior, demonstrating the strong effect of heat treatment parameters on the susceptibility of martensitic stainless steels to corrosion phenomena.
Elastomers are used in almost all areas of industrial applications, such as tires, engine mounts, bridge bearings, seals or coatings. During their use in operation, they are exposed to different environmental influences. These include, in particular, climatic factors such as air oxygen, high temperatures, light (UV radiation) and the influence of media (e.g. oils, fuels). A very important result of these factors is the chemical ageing of elastomers. In this case, the elastomer degenerates and changes its chemical structure in the aged regions, which leads to an irreversible change in the material properties in connection with the reduction in its usability. In this paper, chemical ageing of nitrile butadiene rubber (NBR) is investigated. Especially in case of thermo-oxidative ageing at elevated operating temperatures, the ageing processes run inhomogeneously. These effects are known as diffusion-limited oxidation (DLO) and are associated with the diffusion–reaction behaviour of atmospheric oxygen with the elastomer network. For these reasons, NBR samples are artificially aged in air and subjected to different experimental methods, which are presented and discussed. Additional results from inhomogeneous mechanical tests and permeation tests indicate the causes of the DLO-effect, show the influence of chemical ageing and are subsequently used for parameter identification in relation to the diffusion–reaction equation. A continuum-mechanical modelling approach is also presented here, which describes the finite hyperelasticity, diffusion–reaction processes as well as chemical degradation and reformation of the elastomer network. This multifield problem leads to a system of partial and ordinary differential equations and constitutive equations and is solved within the finite element method.
In this paper, we present and validate the concept of an autonomous aerial robot to reconstruct tomographic 2D slices of gas plumes in outdoor environments. Our platform, the so-called Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), combines a lightweight Tunable Diode Laser Absorption Spectroscopy (TDLAS) gas sensor with a 3-axis aerial stabilization gimbal for aiming at a versatile octocopter. While the TDLAS sensor provides integral gas concentration measurements, it does not measure the distance traveled by the laser diode’s beam nor the distribution of gas along the optical path. Thus, we complement the set-up with a laser rangefinder and apply principles of Computed Tomography (CT) to create a model of the spatial gas distribution from a set of integral concentration measurements. To allow for a fundamental ground truth evaluation of the applied gas tomography algorithm, we set up a unique outdoor test environment based on two 3D ultrasonic anemometers and a distributed array of 10 infrared gas transmitters. We present results showing its performance characteristics and 2D plume reconstruction capabilities under realistic conditions. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO).
In accordance with IAEA SSR-6 para 306 a management system shall be established and implemented to ensure compliance with the relevant provisions of the IAEA regulations. BAM has issued an update of the guideline: the BAM-GGR 011. The new revision describes necessary quality assurance measures for design, manufacture, testing, documentation, use, maintenance and inspection of packagings for package designs requiring competent authority approval for the transport of radioactive material.
The measures can be categorised as system-related and design-related. They are independently approved and monitored by the German competent authority BAM and its authorised expert (BAM/T). The qualification of the organisation applying for the design approval certificate is reviewed in the context of the design approval procedure. The quality assurance measures for manufacture consist of three main steps. Pre-assessment of manufacturing documents such as quality plans, specifications etc., Manufacturing inspections according the pre-assessed documents and inspection before commissioning including documentation review. Periodic inspections during operation as well as relevant specifications for use and maintenance ensure that the properties specified in the approval certificate are preserved over the package life time. Special provisions for the return on
experience regarding operational feedback for design, manufacture, use, maintenance and inspection are given. Special focus shall be given here to the rearranged and meanwhile established system of manufacturing inspections. This includes more transparent roles for a) the Producers authorised inspection 11282 representative, b) the independent inspection expert (S), acting on behalf of the manufacturer with acceptance of BAM, and c) BAM or its authorised expert (BAM/T). Additional attention shall be drawn to the management of deviations during manufacturing and provisions for maintenance and periodic inspections.
Die Empfindlichkeit von Eindring- und Magnetpulverprüfungen (PT, MT) hängt unter anderem von der Eignung und der Qualität der Prüfmittel ab (für PT bezeichnet als Eindringsystem). Die Ermittlung der Empfindlichkeit erfolgt an Kontrollkörpern mit natürlichen und künstlichen Inhomogenitäten durch Ermittlung der Anzeigenerkennbarkeit als Maß für die Eignung. Die europäischen Normen spezifizieren die Anforderungen an die Prüfmittel für Typen-, Chargen- und Betriebsprüfungen nach pr EN ISO 3452-2 für PT und EN ISO 9934-2 für MT. Dieser Beitrag beschreibt die Ermittlung der Empfindlichkeit von Prüfmitteln sowie deren Qualifizierung bei der Typenprüfung. Die vorgeschlagenen Verfahren wurden durch experimentelle Untersuchungen validiert, bei denen ein Bildverarbeitungssystem zur Ermittlung der Anzeigenerkennbarkeit verwendet wurde. Im Hinblick auf die Qualifizierung der Prüfmittel wird die Zuverlässigkeit der Verfahren diskutiert.
A Large Aperture UltraSonic system (LAUS) has been designed and built for testing thick concrete structures. The scalable system consists of twelve ultrasonic units, each hosting 32 individual shear wave transducers with mechanical dry point contact (DPC) to the concrete surface. The twelve units are attached to the concrete surface using a vacuum case which holds them in place during operation. Each LAUS unit can be placed individually on the surface to achieve optimal ultrasonic condition, e.g. to avoid rebars. For the generation of vacuum, air pressure is supplied to each unit through an air hose. The twelve units define an aperture which is necessary for fast reconstruction of the subsurface structure. The well-known SAFT (Synthetic Aperture Focusing Technique) algorithm has been adopted to this situation, where the individual LAUS units form a linear aperture with not necessarily equidistant spacing between the units. The exact geometrical position of the units, which are individually marked with retroreflective labels, is determined using photographs and image processing. All transducers are synchronized and work either as transmitter or receiver. A full scan consists of 12 * 11 recordings, where each unit acts as transmitter once and all others as receivers. An electronic sub-unit on the back of the ultrasonic device holds the battery and handles data acquisition, synchronization and data communication. A computer is used as base unit which communicates with each LAUS unit for control and data acquisition, the synchronization is performed by a radio modem that uses a special algorithm similar to a digital PLL (phase locked loop). No wire connections are necessary between the units and the base system.
The LAUS system is designed to investigate concrete structures with thicknesses in excess of 2 m, depending on the acoustic condition of the object under investigation. Highly reinforced concrete may have less penetration depth. The LAUS provides quasi real time imaging, once the transducers are put in place and the data has been acquired. First measurements on a foundation slab confirm, that the system can register ultrasonic echoes from the back wall at 4 m distance.
This paper introduces a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we introduce and present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile hexacopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing the gas sensing and aiming capabilities under realistic conditions.
Absorption effects and the impact of specimen shape on TXRF analysis has been discussed intensively. Model calculations indicated that ring shaped specimens should give better results in terms of higher counts per mass signals than filled rectangle or circle shaped specimens. One major reason for the difference in signal is shading effects. Full field micro-XRF with a color X-ray camera (CXC) was used to investigate shading, which occurs when working with small angles of excitation as in TXRF. The device allows monitoring the illuminated parts of the sample and the shaded parts at the same time. It is expected that sample material hit first by the primary beam shade material behind it. Using the CXC shading could be directly visualized for the high concentration specimens.
In order to compare the experimental results with calculation of the shading effect the generation of controlled specimens is crucial. This was achieved by 'drop on demand' technology. It allows generating uniform, microscopic deposits of elements. The experimentally measured shadings match well with those expected from calculation.
Synchrotron radiation-induced X-ray fluorescence (SR-XRF) spectrometry was applied to determine iodine concentrations in alluvial Pt–Pd aggregates with delicate morphological features from Córrego Bom Sucesso, Minas Gerais, Brazil. The millimetre-sized botryoidal and rod-shaped grains of alluvial Pt–Pd–Hg intermetallic compounds have surprisingly high concentrations of iodine, in the range from 10 to ~ 120 μg/g. Because iodine is a strongly biophile element, known to be enriched in peatlands and plant remains in soils by microbial activity, its concentration in the Pt–Pd nuggets suggests biogenic precious-metal fixation in the aqueous alluvial milieu. Biogenic and inorganic processes, such as bioreduction and electrochemical metal accretion, could mutually have contributed to the growth of nanoparticles, formed on organic templates, to millimetric Pt–Pd nuggets.
Short-range order has been investigated in Zr69.5Cu12Ni11Al7.5 and Zr41.5Ti41.5Ni17 metallic glasses using X-ray absorption spectroscopy and ab initio molecular dynamics simulations. While both of these alloys are good glass formers, there is a difference in their glass-forming abilities (Zr41.5Ti41.5Ni17 > Zr69.5Cu12Ni11Al7.5). This difference is explained by inciting the relative importance of strong chemical order, icosahedral content, cluster symmetry and configuration diversity.
A novel method that optimizes the screening for antibody-secreting hapten-specific hybridoma cells by using flow cytometry is described. Cell clones specific for five different haptens were analyzed. We selectively double stained and analyzed fixed hybridoma cells with fluorophore-labeled haptens to demonstrate the target-selectivity, and with a fluorophore-labeled anti-mouse IgG antibody to characterize the level of surface expression of membrane-bound IgGs. ELISA measurements with the supernatants of the individual hybridoma clones revealed that antibodies from those cells, which showed the highest fluorescence intensities in the flow cytometric analysis, also displayed the highest affinities for the target antigens. The fluorescence intensity of antibody-producing cells corresponded well with the produced antibodies' affinities toward their respective antigens. Immunohistochemical staining verified the successful double labeling of the cells. Our method makes it possible to perform a high-throughput screening for hybridoma cells, which have both an adequate IgG production rate and a high target affinity.
X-ray imaging methods are used in many fields of research, as they allow a non-destructive Investigation of the elemental content of various samples. As for every imaging method, for X-ray imaging the optics are of crucial importance. However, these optics can be very expensive and laborious to build, as the requirements on surface roughness and precision are extremely high. Angles of reflection and refraction are often in the range of a few mrad, making a compact design hard to achieve. In this work we present a possibility to simplify X-ray imaging. We have adapted the coded aperture method, a high energy radiation imaging method that has its origins in astrophysics, to full field X-ray fluorescence imaging. In coded aperture imaging, an object is projected through a known mask, the coded aperture, onto an area sensitive detector. The resulting image consists of overlapping projections of the object and a reconstruction step is necessary to obtain the information from the recorded image. We recorded fluorescence images of different samples with an energy-dispersive 2D detector (pnCCD) and investigated different reconstruction methods. With a small coded aperture with 12 holes we could significantly increase the count rate compared to measurements with a straight polycapillary optic. We show that the reconstruction of two different samples is possible with a deconvolution approach, an iterative algorithm and a neural network. These results demonstrate that X-ray fluorescence imaging with coded apertures has the potential to deliver good results without scanning and with an improved count rate, so that measurement times can be shortened compared to established methods.