Filtern
Dokumenttyp
Sprache
- Deutsch (2) (entfernen)
Referierte Publikation
- ja (2)
Schlagworte
- Emissionen (1)
- Phthalate (1)
- Richtlinie (1)
- Ringversuch (1)
The applicability of excimer laser at 308 nm and Nd:YAG laser at 532 nm with fluences below 0.86 J/cm2 for cleaning of cellulose and paper materials was evaluated. The extent of degradation of purified cotton cellulose and Fabriano paper after laser treatment as well as after a period of accelerated humid oven ageing was determined by following the changes in the degree of polymerization. While irradiation of paper with the excimer laser at 308 nm results in depolymerization of cellulose accompanied by a decrease in ISO brightness, no detrimental effects of Nd:YAG laser treatments were observed.
Im Rahmen der Richtlinienarbeit der Kommission Reinhaltung der Luft im VDI und DIN - Normenausschuss KRdL wurde ein Ringversuch zur Validierung des Analysenverfahrens für Phthalate in der Innenraumluft durchgeführt. Dabei wurden die beiden in der künftigen Richtlinie beschriebenen Analysenverfahren der Thermodesorption von Adsorptionsröhrchen sowie der Lösemittelextraktion von Florisilröhrchen mit jeweils anschließender Gaschromatographie und Massenspektrometrie (GC/MS) erprobt. Die Ergebnisse des Ringversuchs belegen die Vergleichbarkeit der beiden Verfahren. Auch die Richtigkeit der Ergebnisse im Rahmen einer akzeptablen Streuung sowie die Praktikabilität in der Praxis konnten bestätigt werden. Weiterhin wurden wichtige Erkenntnisse zur Minimierung der Blindwerte erarbeitet.