Filtern
Dokumenttyp
Sprache
- Englisch (4)
Schlagworte
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (4) (entfernen)
Solutions of organic analytes of known mass fraction are typically used to calibrate the measurement processes used to determine these compounds in matrix samples. Appropriate value assignments and uncertainty calculations for calibration solutions are critical for accurate measurements. Evidence of successful participation in formal, relevant international comparisons is needed to document measurement capability claims (CMCs) made by national metrology institutes (NMIs) and designated institutes (DIs). To enable NMIs and DIs to update or establish their claims, in 2015 the Organic Analysis Working Group (OAWG) sponsored CCQM-K131 "Low-Polarity Analytes in a Multicomponent Organic Solution: Polycyclic Aromatic Hydrocarbons (PAHs) in Acetonitrile".
Polycyclic aromatic hydrocarbons (PAHs) result from combustion sources and are ubiquitous in environmental samples. The PAH congeners, benz[a]anthracene (BaA), benzo[a]pyrene (BaP), and naphthalene (Nap) were selected as the target analytes for CCQM-K131. These targets span the volatility range of PAHs found in environmental samples and include potentially problematic chromatographic separations. Nineteen NMIs participated in CCQM-K131. The consensus summary mass fractions for the three PAHs are in the range of (5 to 25) μg/g with relative standard deviations of (2.5 to 3.5) %.
Successful participation in CCQM-K131 demonstrates the following measurement capabilities in determining mass fraction of organic compounds of moderate to insignificant volatility, molar mass of 100 g/mol up to 500 g/mol, and polarity pKow < −2 in a multicomponent organic solution ranging in mass fraction from 100 ng/g to 100 μg/g: (1) value assignment of primary reference standards (if in-house purity assessment carried out), (2) value assignment of single and/or multi-component organic solutions, and (3) separation and quantification using gas chromatography or liquid chromatography.
Extraction, chromatographic separation, and quantification of low-concentration organic compounds in complex matrices are core challenges for reference material producers and providers of calibration services. Evidence of successful participation in formal, relevant international comparisons is needed to document measurement capability claims made by national metrology institutes (NMIs) and designated institutes (DIs). To enable NMIs and DIs to update or establish their claims, in 2014 the Organic Analysis Working Group (OAWG) initiated CCQM-K95.1 "Low-Polarity Analytes in a Botanical Matrix: Polycyclic Aromatic Hydrocarbons (PAHs) in Tea". This was a follow-on comparison from CCQM-K95 which was completed in 2014.
The polycyclic aromatic hydrocarbons (PAHs) benz[a]anthracene (BaA) and benzo[a]pyrene (BaP) are considered priority pollutants by U.S. Environmental Protection Agency and are regulated contaminants in food, pose chromatographic separation challenges, and for which exist well-characterized measurement procedures and standard materials. BaA and BaP in a smoked tea were therefore selected as representative target measurands for CCQM-K95.1. Ten NMIs participated in CCQM-K95.1. The consensus summary mass fractions for the two PAHs are in the range of (50 to 70) ng/g with relative standard deviations of (6 to 10) %.
Successful participation in CCQM K95.1 demonstrates the following measurement capabilities in determining mass fraction of organic compounds, with molar mass of 100 g/mol to 500 g/mol and having polarity pKow −2, in a botanical matrix ranging in mass fraction from 10 ng/g to 1000 ng/g: (1) value assignment of primary reference standards (if in-house purity assessment carried out), (2) value assignment of single and/or multi-component organic solutions, (3) extraction of analytes of interest from the matrix, (4) cleanup and separation of analytes of interest from interfering matrix or extract components, and (5) separation and quantification using gas chromatography or liquid chromatography.
The comparison required the assignment of the mass fraction of folic acid present as the main component in the comparison sample. Performance in the comparison is representative of a laboratory's measurement capability for the purity assignment of organic compounds of medium structural complexity [molecular weight range 300–500] and high polarity (pKOW < −2).
Methods used by the eighteen participating NMIs or DIs were based on a mass balance (summation of impurities) or qNMR approach, or the combination of data obtained using both methods. The qNMR results tended to give slightly lower values for the content of folic acid, albeit with larger associated uncertainties, compared with the results obtained by mass balance procedures. Possible reasons for this divergence are discussed in the report, without reaching a definitive conclusion as to their origin.
The comparison demonstrates that for a structurally complex polar organic compound containing a high water content and presenting a number of additional analytical challenges, the assignment of the mass fraction content property value of the main component can reasonably be achieved with an associated relative standard uncertainty in the assigned value of 0.5%
The presence of any aflatoxin contamination in exported figs needs to be monitored and measured through reliable and traceable methods, which require pure and matrix certified reference materials. On the other hand, certified reference materials (CRM) for determination of aflatoxins in dried fig are not yet available. Moreover, there is a lack of CRMs to be used in routine testing laboratories for method validation and quality control. The routine testing laboratories, participating in commercial proficiency testing (PT) programs, use the results available from consensus values to evaluate the performance of the participating laboratories, rather than metrologically traceable assigned values. This study initially proposed as a key comparison and presented at the EURAMET TC-MC SCOA meeting in Malta in 2015 and subsequently at the CCQM OAWG meeting in April 2015, proposes a CRM candidate for determination of levels of aflatoxins B1, B2, G1, G2 and their total in dried. Evidence of successful participation in formal, relevant international comparisons are needed to document measurement capability claims (CMCs) made by national metrology institutes (NMIs) and designated institutes (DIs).
In total nine NMI/DI participated in the Track C Key Comparison CCQM-K138 Determination of aflatoxins (AFB1, AFB2, AFG1, AFG2 and Total AFs) in Dried Fig. Participants were requested to evaluate the mass fractions expressed in ng/g units, of aflatoxins B1, B2, G1, G2 and total aflatoxin in a dried food matrix, dried fig. The CCQM-K138 results for the determination of aflatoxins (AFB1, AFB2, AFG1, AFG2 and total AFs) are ranging from 5.17 to 7.27 ng/g with an %RSD of 10.47 for AFB1, ranging from 0.60 to 0.871 ng/g with an %RSD of 11.69 for AFB2, ranging from 1.98 to 2.6 ng/g with an %RSD of 10.36 for AFG1, ranging from 0.06 to 0.32 ng/g with an %RSD of 35.6 for AFG2, and ranging from 8.29 to 10.31 ng/g with an %RSD of 7.69 for Total AFs. All participants based their analyses on LC-MS/MS, HPLC-FLD, HR-LC/MS, and IDMS. Brief descriptions of the analytical methods used by the participants, including sample preparation, analytical technique, calibrants, and quantification approach are summarized in Appendix F. Linear Pool was used to assign the Key Comparison Reference Values (KCRVs) for B1, B2, G1, G2 and total aflatoxins. Due to the traceability requirements for the calibrants not being met, results of KEBS, INTI, VNIIM and BAM were excluded from KCRV determination.
Successful participation in CCQM-K138 demonstrates the following measurement capabilities in determining mass fraction of organic compounds, with molecular mass of 100 g/mol to 500 g/mol, having high polarity (pKow > -2), in mass fraction range from 0.05 ng/g to 500 ng/g in dried food matrices.