Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Biomaterial (5)
- Bone (5)
- Biocompatibility (4)
- Ceramics (4)
- RFA (4)
- Röntgenfluoreszenzanalyse (4)
- Coating (3)
- Drawings (3)
- Recycling (3)
- Silberstiftzeichnung (3)
- Silverpoint drawing (3)
- Surface reaction (3)
- Synchrotron (3)
- X-ray spectrometry (3)
- XRF (3)
- XRF analysis (3)
- Albrecht Dürer (2)
- Archaeometry (2)
- Archäometrie (2)
- Beschichtung (2)
- Biomass (2)
- CdTe (2)
- Kinetics (2)
- Porosity (2)
- Pyrolysis (2)
- TGA (2)
- Zeichnungen (2)
- 3D printing (1)
- Additive Manufacturing (1)
- Alcium alkali phosphate (1)
- Bio active ceramic (1)
- Bioactive bone cement (1)
- Bioactive glass (1)
- Bioaktiv (1)
- Bioaktiver Knochenzement (1)
- Bioaktivität (1)
- Biodegradability (1)
- Biodegradation (1)
- Biokeramik (1)
- Biomaterial-bone-coating of an implant (1)
- Biomompatibilität (1)
- Bone defect (1)
- Bone substitute materials (1)
- Bone tissue engineering (1)
- CCQM (1)
- CIGS (1)
- CIS (1)
- Cadmium (1)
- Calcium alkali orthophosphate (1)
- Calcium alkali orthophosphates (1)
- Calcium alkaline orthophosphates (1)
- Calcium alkaline phosphates (1)
- Calcium phosphate (1)
- Calcium phosphate ceramics (1)
- Calcium-alkali-orthophosphate (1)
- Calcium-alkali-orthophosphate ceramics (1)
- Calciumalkaliorthophosphat (1)
- Calciumphosphat (1)
- Calciumtitanat (1)
- Catheters (1)
- Cell culture media (1)
- Central venous access port (1)
- Ceramic (1)
- Ceramic scaffolds (1)
- Chalcogenide photovoltaics (1)
- Char conversion (1)
- Char reactivity (1)
- Chromium (1)
- Coating(s) (1)
- Competencies (1)
- Complication (1)
- Curriculum (1)
- Denkmalpflege (1)
- Density (1)
- Dentin (1)
- EDX (1)
- Energy harvesting (1)
- Experimental study (1)
- Fetal bovine serum (1)
- Fitting (1)
- Gold (1)
- Histologie (1)
- Histology (1)
- Histomorphometrie (1)
- Histomorphometry (1)
- IFM (1)
- Implantatbeschichtung (1)
- In-vivo (1)
- Isoconversional (1)
- Kalzium Phosphat Zement, amorph. (1)
- Kalzium-Phosphat (1)
- Knochendefekt (1)
- Knochenersatz (1)
- Knochenkontakt (1)
- Lead (1)
- Leichtgranulat (1)
- Life cycle analysis (1)
- Mandible (1)
- Mass burning rate (1)
- Mass deposition (1)
- Mechanical processing (1)
- Mechanical testing (1)
- Mercury (1)
- Mineralization (1)
- Modeling (1)
- NDT-CE (1)
- Nuclear industry (1)
- Nuclear medicine (1)
- Oral surgery (1)
- Osteoblast differentiation (1)
- Osteoclast (1)
- Osteoclasts (1)
- Peptide synthesis (1)
- Photovoltaic (1)
- Plasmasprühen (1)
- Plastic (1)
- Polypropylene (1)
- Pool fire (1)
- Rapid prototyping (1)
- Reference material (1)
- Restauriermörtel (1)
- RoHS (1)
- Röntgenfluoreszenzanalyse (RFA) (1)
- STRATAGem (1)
- SaOS-2 cells (1)
- Scaffold (1)
- Schutzschicht (1)
- Silicone rubber (SiR) (1)
- Silver stylus (1)
- Simulated body fluid (1)
- Smouldering (1)
- Solubility (1)
- Stressed (1)
- Structure propertyrelationship (1)
- Surface Reaction (1)
- Surface analysis (1)
- TBPB (tert-butyl-peroxy benzoat) (1)
- Thermogravimetric analysis (1)
- Thermomagnetic generator (1)
- Thermoplastic polyurethane (TPU) (1)
- Thin film (1)
- Thin film modules (1)
- Three-dimensional (1)
- TiO2 (1)
- Titanträgermaterial (1)
- Toxicity (1)
- University (1)
- Unstressed (1)
- WEEE (1)
- Woody biomass (1)
- X-ray fluorescence (1)
- X-rays (1)
- Zement (1)
- crystal structures (1)
- gold (1)
- serine-protease inhibitor (1)
- Überzug (1)
Organisationseinheit der BAM
Central venous port devices made of two different polymeric materials, thermoplastic polyurethane (TPU)and silicone rubber (SiR), were compared due their material properties. Both naïve catheters as well as catheters after removal from patients were investigated. In lab experiments the influence of various chemo-therapeutic solutions on material properties was investigated, where as the samples after removal were compared according to the implanted time inpatient. The macroscopic,mechanical performance was assessed with dynamic, specially adapted tests for elasticity. The degradation status of the materials was determined with common tools of polymer characterisation, such as infrared spectroscopy, molecular weight measurements and various methods of thermal analysis. The surface morphology was an alysed using scanning electron microscopy. A correlation between material properties and clinical performance was proposed. The surface morphology and chemical composition of the polyurethane catheter materials can potentially result in increased susceptibility of the catheter to bloodstream infections and thrombotic complications. The higher mechanic failure,especially with increasing implantation time of the silicone catheters is related to the lower mechanical performance compared to the polyurethane material as well as loss of barium sulphate filler particles near the surface of the catheter. This results in preformed microscopic notches, which act as predetermined sites of fracture.
One of the crucial characteristics of functionalized thin films is their porosity (i.e., the ratio between the pore volume and the volume of the whole film). Due to the very low amount of material per coated area corresponding to thin films, it is a challenge for analytics to measure the film porosity. In this work, we present an Approach to determine the porosity of thin films by means of electron probe microanalysis (EPMA) either by wavelength-dispersive X-ray spectrometry (WDX) or by energy-dispersive X-ray spectrometry (EDX) with a scanning electron microscope (SEM). The procedure is based on the calculation of the film mass deposition from electron-excited X-ray spectra. The
mass deposition is converted into film density by division of measured film thickness.
Finally, the film porosity is calculated from the measured film density and the density of bulk, nonporous film material. The general applicability of the procedure to determine the
porosity is demonstrated on thin templated mesoporous TiO₂
films, dip-coated on silicon
wafer, with controlled porosity in the range of 15 to 50%. The high accuracy of the mass deposition as determined from X-ray spectra was validated with independent methods (ICP-OES and weighing). Furthermore, for the validation of the porosity results, ellipsometry, interference fringes method (IFM), and focused ion beam (FIB) cross sectioning were employed as independent techniques. Hence, the approach proposed
in the present study is proven to be suited as a new analytical tool for accurate and relatively fast determination of the porosity of thin films.
To date, there are very few technologies available for the conversion of low-temperature waste heat into electricity. Thermomagnetic generators are one approach proposed more than a century ago. Such devices are based on a cyclic change of magnetization with temperature. This switches a magnetic flux and, according to Faraday’s law, induces a voltage. Here we demonstrate that guiding the magnetic flux with an appropriate topology of the magnetic circuit improves the performance of thermomagnetic generators by orders of magnitude. Through a combination of experiments and simulations, we show that a pretzel-like topology results in a sign reversal of the magnetic flux. This avoids the drawbacks of previous designs, namely, magnetic stray fields, hysteresis and complex geometries of the thermomagnetic material. Our demonstrator, which is based on magnetocaloric plates, illustrates that this solid-state energy conversion technology presents a key step towards becoming competitive with thermoelectrics for energy harvesting near room temperature.
Osteoclastic bioresorption of biomaterials: Two- and three-dimensional imaging and quantification
(2010)
Purpose: Bioresorbable materials have been developed in the hope that the body will replace them with newly formed tissue. The first step of this remodeling process in bone is the bioresorption of the material by osteoclasts. The aim of this study was to analyze osteoclastic resorption of biomaterials in vitro using the commonly used two-dimensional methods of light-microscopy (LM) and scanning electron microscopy (SEM) in comparison with infinite focus microscopy (IFM), a recently developed imaging method allowing for three-dimensional surface analysis. Methods: Human hematopoietic stem cells were cultivated in the presence of the cytokines M-CSF and RANK-L for 4 weeks directly on dentin and a calcium phosphate cement. Osteoclast development was surveyed with standard techniques. After removal of the cells, resorption was characterized and quantified by LM, SEM and IFM. Results: Osteoclast cultures on the biomaterials presented the typical osteoclast-specific markers. On dentin samples LM, SEM as well as IFM allowed for discrimination of resorption. Quantification of the resorbed area showed a linear correlation between the results (LM vs. SEM: r=0.996, p=0.004; SEM vs. IFM: r=0.989, p=0.011; IFM vs. LM: r=0.995). It was not possible to demarcate resorption pits on GB14 using LM or SEM. With IFM, resorption on GB14 could be visualized and quantified two- and three-dimensionally.
Commonly, to determine osteoclastic resorption of biomaterials only the resorbed area is measured. The depth of the resorption pit, however, may also be important for the performance of a material. To generate such data we used two calcium phosphate ceramics (Ca10 and Ca2). The solubility of the materials was determined according to DIN EN ISO 10993-14. They were scanned three-dimensionally using infinite focus microscopy and subsequently cultivated for 4 weeks in simulated body fluid without (control) or with human osteoclasts. After this cultivation period osteoclasts number was determined and surface changes were evaluated two- and three-dimensionally. Ca10 and Ca2 showed solubilities of 11.0 ± 0.5 and 23.0 ± 2.2 mg g-1, respectively. Both materials induced a significant increase in osteoclast number. While Ca10 did not show osteoclastic resorption, Ca2 showed an increased pit area and pit volume due to osteoclastic action. This was caused by an increased average pit depth and an increased number of pits, while the average area of single pits did not change significantly. The deduced volumetric osteoclastic resorption rate (vORR) of Ca2 (0.010.02 µm3 µm-2 day-1) was lower than the remodelling speed observed in vivo (0.08 µm3 µm-2 day-1), which is in line with the observation that implanted resorbable materials remain in the body longer than originally expected. Determination of volumetric indices of osteoclastic resorption might be valuable in obtaining additional information about cellular resorption of bone substitute materials. This may help facilitate the development of novel materials for bone substitution.