Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Haftfestigkeit (4)
- Klebfestigkeit (3)
- Acoustic levitation (2)
- Mass spectrometry (2)
- Mehr-Proben-Vorbehandeln/Kleben/Prüfen (2)
- 16S amplicons (1)
- ALD-Abscheidungen (1)
- Adhesion (1)
- Adhesives and adhesive tapes (1)
- Aeolian (1)
- Amorphization (1)
- Bodélé Depression (1)
- Bonding strength (1)
- Certified reference material (1)
- Chad (1)
- Collision induced dissociation (CID) (1)
- Crystallization (1)
- Cyclic voltammetry (1)
- Desert soil (1)
- Deserts (1)
- Double strands (1)
- Electrochromic device (1)
- Electrochromism (1)
- Electrospray (1)
- Eukaryota (1)
- Femtosecond laser (1)
- High throughput sequencing (1)
- Intercontinental dust (1)
- Ion mobility spectrometry (1)
- Laser ablation (1)
- Laserellipsometrie (1)
- Locked nucleic acids (1)
- Mehr-Proben-Prüfen/Kleben (1)
- Metagenomics (1)
- Metallo-supramolecular polyelectrolytes (1)
- Multiple-sample bonding (1)
- Multiple-sample testing (1)
- Ni-base superalloy (1)
- Nitrides (1)
- Oligonucleotide fragmentation (1)
- Optical properties (1)
- Physical vapour desposition (1)
- Plasma Vorbehandlung (1)
- Protein analysis (1)
- Republic of Chad (1)
- Scratch test (1)
- Silicon (1)
- Spectroscopic imaging ellipsometry (1)
- Standardisation (1)
- Structural properties (1)
- THz-Wellen (1)
- Terahertzsysteme (1)
- Test methods (1)
- Thermo-mechanical fatigue (1)
- Vanadium oxide (1)
- Wind erosion (1)
- XAFS (1)
- Zentrifugentechnologie (1)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
The combination of acoustically levitated droplets, mid-IR laser evaporation, and subsequent post-ionization by secondary electrospray ionization was applied for monitoring the enzymatic digestion of various proteins. Acoustically levitated droplets are an ideal, wall-free model reactor, readily allowing compartmentalized microfluidic trypsin digestions. Time-resolved interrogation of the droplets yielded real-time information on the progress of the reaction and thus provided insights into reaction kinetics. After 30 min of digestion in the acoustic levitator, the obtained protein sequence coverages were identical to the reference overnight digestions. Importantly, our results clearly demonstrate that the applied experimental setup can be used for the real-time investigation of chemical reactions. Furthermore, the described methodology only uses a fraction of the typically applied amounts of solvent, analyte, and trypsin. Thus, the results exemplify the use of acoustic levitation as a green analytical chemistry alternative to the currently used batch reactions.
The composition of acoustically levitated droplets was probed by a novel combination of mid-IR laser evaporation and subsequent postionization via secondary electrospray ionization. The combination of microliter samples and subnanoliter sampling provided time-resolved interrogation of droplets and allowed for a kinetic investigation of the laser-induced release of the analyte, which was found to strongly depend on the analytes. The observed substancespecific delayed release of the analytes permitted baseline-separated discrimination of the analytes, ideal for the study of complex samples.
The additionally applied postionization scheme was found to enable efficient detection of small volatile compounds as well as peptides. The detection of small molecules and peptides occurred under very different sampling geometries, pointing to two distinct underlying ionization mechanisms. Overall, our results suggest that the experimental setup presented in this study can serve as a widely applicable platform to study chemical reactions in acoustically levitated droplets as model reactors.
Single Femtosecond Laser-Pulse-Induced Superficial Amorphization and Re-Crystallization of Silicon
(2021)
Superficial amorphization and re-crystallization of silicon in <111> and <100> orientation after irradiation by femtosecond laser pulses (790 nm, 30 fs) are studied using optical imaging and transmission electron microscopy. Spectroscopic imaging ellipsometry (SIE) allows fast data acquisition at multiple wavelengths and provides experimental data for calculating nanometric amorphous layer thickness profiles with micrometric lateral resolution based on a thin-film layer model. For a radially Gaussian laser beam and at moderate peak fluences above the melting and below the ablation thresholds, laterally parabolic amorphous layer profiles with maximum thicknesses of several tens of nanometers were quantitatively attained. The accuracy of the calculations is verified experimentally by high-resolution transmission electron microscopy (HRTEM) and energy dispersive X-ray spectroscopy (STEM-EDX). Along with topographic information obtained by atomic force microscopy (AFM), a comprehensive picture of the superficial re-solidification of silicon after local melting by femtosecond laser pulses is drawn.
DNA and locked nucleic acid (LNA) were characterized as single strands, as well as double stranded DNA-DNA duplexes and DNA-LNA hybrids using tandem mass spectrometry with collision-induced dissociation. Additionally, ion mobility spectrometry was carried out on selected species. Oligonucleotide duplexes of different sequences – bearing mismatch positions and abasic sites of complementary DNA 15-mers – were investigated to unravel general trends in their stability in the gas phase. Single stranded LNA oligonucleotides were also investigated with respect to their gas phase behavior and fragmentation upon collision-induced dissociation. In contrast to the collision-induced dissociation of DNA, almost no base loss was observed for LNAs. Here, backbone cleavages were the dominant dissociation pathways. This finding was further underlined by the need for higher activation energies. Base losses from the LNA strand were also absent in fragmentation experiments of the investigated DNA-LNA hybrid duplexes. While DNA-DNA duplexes dissociated easily into single stranded fragments, the high stability of DNA-LNA hybrids resulted in predominant fragmentation of the DNA part rather than the LNA, while base losses were only observed from the DNA single strand of the hybrid.
Die nicht ionisierende elektromagnetische Strahlung im Bereich von Terahertz-Frequenzen ermöglicht berührungslose und zerstörungsfreie Mess- und Prüftechnik in zahlreichen Bereichen. Nach ersten Anwendungen in der Astronomie und der Atmosphärenforschung wurden in letzter Zeit Anwendungsfelder in der Sicherheitstechnik, der Medizintechnik, der Nachrichtentechnik und der zerstörungsfreien Prozess- und Qualitätskontrolle erschlossen. Dielektrische Materialien wie Kunststoffe und Keramiken können von Terahertz-Wellen durchdrungen werden. Das ermöglicht Untersuchungen des Objektinneren ohne spezielle Schutzmaßnahmen, wie sie z.B. beim Röntgen notwendig sind. Die Richtlinie erleichtert die Verständigung zwischen Nutzern, Herstellern und dem Vertrieb von Terahertz-Systemen. In der Richtlinie werden bekannte Einsatzgebiete sowie die eingesetzten Verfahren und Funktionsprinzipien aufgeführt, um den Leser bei der Auswahlentscheidung zu unterstützen. Nach einer kurzen Einführung in die physikalischen Grundlagen und Hinweisen zur elektromagnetischen Verträglichkeit, zum Strahlenschutz und zur regulierten Frequenzvergabe werden die verschiedenen Geräteklassen von Terahertz-Systemen ausführlich vorgestellt. Die Richtlinie gibt Hinweise zur messtechnischen Charakterisierung von Terahertz-Wellen. Einsatzgebiete von Terahertz-Systemen, wie die zerstörungsfreie Prüfung, die Dicken- und Abstandsmessung, die Tomografie und die chemische Analytik, werden mit ihren spezifischen Eigenschaften im Detail beschrieben. Umfangreiche Literaturverweise vereinfachen eine vertiefte Beschäftigung mit den Themen der Richtlinie. Eine tabellarische Übersicht mit einer Zusammenfassung, welche Terahertz-Systeme für welche Anwendungsfelder eingesetzt werden können, vervollständigt die Richtlinie.
Aufzählung der wichtigsten wissenschaftlich-technischen und anderer wesentlicher Ergebnisse
• ALD Abscheidungen auf Polymeren (PE, PP, PTFE) unter Atmosphärendruck und im Vakuum mit Ozon als Oxidationsmittel wurden durchgeführt:
- Mit Variation der Schichtdicke
- Mit Variation der Zykluszeit
- Mit und ohne Ozon Vorbehandlung der Oberfläche
• ALD Abscheidungen auf (PE, PP, PTFE) in Vakuum mit O2- und H2-Plasma Vorbehandlung wurden durchgeführt.
- Mit Variation der Schichtdicke
- Mit Variation der Zykluszeit
- Mit und ohne Plasma Vorbehandlung der Oberfläche
• Die ALD Prozesse wurden mit in situ Laserellipsometrie untersucht.
• Die ALD Schichten wurden für die Haftfestigkeit bei der BAM ausgewerte
The multiple-sample approach by means of centrifugal adhesion testing (CAT-technology) allows the determination of bonding strength of adhesive-bonded joints on a statistical basis of up to eight samples. Therefore, it is obvious to ensure the continuous handling and identical processing of an octet of samples within the entire process chain of wet-chemical cleaning, plasma-chemical pre-treatment, bonding of samples, and testing of bonding strength. Within the multiple-sample bonding set-up (MPKV-technology) a defined bonding pressure can be adjusted regardless the actual number of samples. A comparison of single- and multiple-sample approach is made for bonding strength of selected adhesives, double-sided adhesive tapes and different material combinations [stainless steel (V2A) vs. stainless steel, polyamide (PA), or polypropylene (PP)]. It is shown that both technologies improve reliability of results
Flexible electrochromic devices (ECDs) based on Fe(II)-metallo-supramolecular polyelectrolytes (Fe-MEPE) and vanadium oxide are studied in operando by means of x-ray absorption fine structure (XAFS) spectroscopy. The ECDs are blue-purple in the colored state at 0.0 V and become light yellow when a voltage of 1.6 V is applied. The XAFS studies at the K-edge of Fe(II) reveals that the absorption edge is shifted toward higher energies by 1.8 eV in the transparent state. Comparison of two different ECDs and different charge cycles demonstrates the reversibility and repeatability of the process. We attribute the shift to a charge transfer and a change of oxidation state of the ions from Fe2+ to Fe3+. The transition is not accompanied by a noticeable structural change of the octahedral coordination geometry as confirmed by analysis of the extended x-ray absorption fine structure (EXAFS) data. (C) 2015 Elsevier B.V. All rights reserved.
Die Bestimmung der Haftfestigkeit von Lackierungen, Beschichtungen oder Klebungen ist wichtig für die Beurteilung von entsprechenden Fertigungsabläufen. Unter Verwendung einer neuen Zentrifugentechnik wurde jetzt ein neues Mehr-Proben-Konzept zur schnellen Validierung von Klebverbindungen entwickelt.
Die Bestimmung der Haftfestigkeit von Lackierungen, Beschichtungen oder Klebeverbunden ist ein wichtiges Analyseinstrument bei der Beurteilung von entsprechenden Fertigungsabläufen. Unter Verwendung einer neuen Zentrifugentechnologie wurde in einem AiF Forschungsprojekt OKTETT die gesamte Prozesskette Vorbehandlung - Verklebung - Prüfung validiert.