Filtern
Dokumenttyp
Sprache
- Englisch (5)
Schlagworte
- Porosity (3)
- Ammonium nitrate (2)
- Non-destructive characterisation (2)
- Prill (2)
- Specific surface area (2)
- ANFO (1)
- Data processing (1)
- Dust layers (1)
- Explosives (1)
- Minimum ignition temperature (1)
Organisationseinheit der BAM
- 2 Prozess- und Anlagensicherheit (5) (entfernen)
Thermoelectric generator (TEG) has been proved as a promising technology for directly converting heat into electricity based on Seebeck effect. On the contrary, this electricity can trigger a solid-state cooling based on conventional Peltier effect. However, these two effects induce a coupling between heat and electric flux, especially for the quantitative relationship still remaining a mystery. Here, we show experimental evidence and theoretical calculation for the coupling by monitoring transient response of fluid temperature and output power. The experimental maximum heat flow in open circuit is 1162 W at cold fluid flow rate = 0.3 m3/h and fluid temperature difference ΔTf = 70 °C, enhanced by 13% owing to heat compensation from intrinsic coupling in closed-loop circuit. Meanwhile, the measured maximum output power of TEG is 18.2 W, and subsequently decreases to 15.4 W due to the objective existence of coupling. This double-edged sword in coupling vigorously inspires the potential applications in heat-dissipation situation such as spacecraft, electronic components, photovoltaic, refrigerator and etc. Present findings open a novel avenue for manipulating heat-electricity conversion in practical engineering.
The mixture of ammonium nitrate (AN) prills and fuel oil (FO), usually called ANFO, is extensively used in the mining industry as a bulk industrial explosive. One of the major performance predictors of ANFO mixtures is the fuel oil retention, which is itself governed by the porosity of the AN prills. Standardised tests routinely used to assess oil retention face several important limitations; the first being the difficulty to cover the wide range of porosity contents and morphologies from different types of ammonium nitrate prills; the second being the inability to evaluate the closed porosity, which is an important factor regarding the sensitivity of the explosive to detonation. In this study, we present how X-ray computed tomography (XCT), and the associated advanced data processing workflow, can be used to fully characterise the structure and morphology of AN prills. We show that structural parameters such as volume fraction of the different phases and morphological parameters such as specific surface area and shape factor can be reliably extracted from the XCT data, and that there is a good agreement with the measured oil retention values. XCT can therefore be employed to non-destructively and accurately evaluate and characterise porosity in ammonium nitrate prills.
The mixture of ammonium nitrate (AN) prills and fuel oil (FO), usually referred to as ANFO, is extensively used in the mining industry as a bulk explosive. One of the major performance predictors of ANFO mixtures is the fuel oil retention, which is itself governed by the complex pore structure of the AN prills. In this study, we present how X-ray computed tomography (XCT), and the associated advanced data processing workflow, can be used to fully characterise the structure and morphology of AN prills. We show that structural parameters such as volume fraction of the different phases and morphological parameters such as specific surface area and shape factor can be reliably extracted from the XCT data, and that there is a good agreement with the measured oil retention values. Importantly, oil retention measurements (qualifying the efficiency of ANFO as explosives) correlate well with the specific surface area determined by XCT. XCT can therefore be employed non-destructively; it can accurately evaluate and characterise porosity in ammonium nitrate prills, and even predict their efficiency.
Ammonium nitrate (AN) prills are commonly used as an ingredient in industrial explosives and in fertilisers. Conventional techniques (such as BET or mercury intrusion porosimetry) can measure the open porosity and specific surface area of AN prill, but the closed porosity is not obtainable. This work was focused on evaluating X-ray computed tomography (XCT) as a non-destructive technique for the assessment of porosity in AN prills. An advanced data processing workflow was developed so that the segmentation and quantification of the CT data could be performed on the entire 3D volume, yet allowing the measurements (e.g.; volume, area, shape factor…) to be extracted for each individual phase (prill, open porosity, closed porosity) of each individual prill, in order to obtain statistically relevant data. Clear morphological and structural differences were seen and quantified between fertiliser and explosive products. Overall, CT can provide a very wide range of parameters that are not accessible to other techniques, destructive or non-destructive, and thus offers new insights and complementary information.
Industrial fires and explosions initiating from self-ignition of combustible porous dust deposits represent a serious hazard for human beings, environment and industry. Understanding the fundamental basis of combustible dust ignition behaviours at different geometries is of importance to prevent and mitigate the accidental risks. A correlation of self-ignition temperatures (SITs) measured by hot-oven tests and minimum ignition temperatures of dust layers (MITLs) determined by hot-plate tests has been established previously. However, this analogy approach based on Frank-Kamenetzkii model is limited by ignoring the influence of oxygen diffusion. In this work, an improved method is developed by implementing a correction factor for the pre-exponential factor caused by the boundary geometry. This method is testified by comparing with experimental data, previous analogy method and numerical simulation. Results show that our proposed method performs a better predictability of MITLs and simplicity. The improved analogy method indicates that the different boundary geometries of a dust deposit significantly impact the apparent pre-exponential factor, while have an ignorable influence on the activation energy, which is also verified by numerical investigations. Furthermore, the numerical model with the corrected kinetic parameters provides a satisfactory explanation compared with experimental observations regarding to temperature and concentration evolutions of dust layers.