Godbert-Greenwald furnace was used to investigate the minimum ignition temperature of dust clouds (MITC) in air with the presence of flammable gas which is lower than its lower explosion limit (LEL). Three flammable gases (CH4, H2 and CO) and three carbonaceous dusts (anthracite coal, bituminous coal and sweet potato starch) were tested. Results showed that all flammable gases have distinct effects on the MITC of the dust samples and volatile matter content of dust plays an important role during the ignition process. Specifically, the MITC of anthracite coal dust decreased from 610 °C to 560 °C, 580 °C and 570 °C with 3% CH4, 3% CO and 2.5% H2, respectively. Moreover, a heterogeneous ignition mechanism model was proposed to verify the equally global ignition characteristic between hybrid anthracite coal-CxHy mixture and bituminous coal. All three gases had an ignorable effect on the MITC of starch dust considering the experimental error. The presence of CO and H2 slightly promoted the ignition of bituminous coal dust, but the addition of CH4 showed a distinct concentration effect on the MITC of bituminous coal: the MITC decreased with 1% CH4 while increased with 2% and 3% CH4.
This negative-effect of flammable gases at such low concentrations on ignition temperature of bituminous coal dusts was found for the first time. Furthermore, the presence of the 2nd flammable gas had a smaller effect on the MITC of dust samples with a higher volatile content, resulted from the competition of heterogeneous and homogeneous ignition mechanisms.
Minimum explosion concentrations of coal dusts with CH4/H2/CO below the gas lower explosion limit
(2020)
A 20-L spherical explosion chamber was used to investigate the explosion characteristics of dust clouds in air with the presence of flammable gas which is lower than its lower explosion limit (LEL).
including minimum explosion concentration (MEC) of dust. Explosion pressure (Pex) and explosion pressure rise (dp/dt)ex). Two dust samples (anthracite coal, bituminous coal) and were three flammable gases (CH4, H2 and CO) were tested. Experimental results showed that the explosion of hybrid mixtures occurs when both dust and gas concentrations are lower than the LEL/MEC of the single substances.
Meanwhile. all flammable gases with different volume fractions have distinct effects on the MEC. Pex and (dp/dt)ex of the dust samples.
With the increase of the flammable gas concentration. either the Pex and (dp/dt)ex increase or the MEC decreases for all the hybrid mixtures of both two dust samples. At the same concentration of coal dusts. the addition of CH4 promotes higher explosion risks than the other two flammable gases. The distribution of (dp/dt)ex is quite different with the restricted area defined by empirical formulas.
These results improve our understanding of the explosion behaviour and the explosion risk of hybrid dust-gas mixtures in air.
The space heating system accounts for 20%~50% of building energy consumption, and may lead to energy waste due to unreasonable controls. In this study, an energy-efficient floor heating system with intelligent control was proposed to improve energy efficiency of the system. In order to validate the concept of the proposed intelligent control, an experimental system was designed and constructed in Chengdu, China. Temperature, control cycle and energy consumption were then studied under different control strategies. The result shows that a larger flow rate of supply water will result in a longer control cycle and a lower control frequency, i.e., the average control cycle at 7 L min−1 is 1.7 h during the test day, while it is 1.5 h at 5 L min−1. Moreover, adopting water with a higher temperature and flow rate could achieve a higher efficiency of the system. The energy consumptions in case 1 (5 L min−1, 50 °C), case 2 (5 L min−1, 55 °C), case 5 (7 L min−1, 55 °C) and case 6 (7 L min−1, 60 °C) are 4746 kJ, 3534 kJ, 3093 kJ and 3028 kJ, respectively. Based on the experimental data, the supply water temperature is suggested to set lower than 60 °C considering human comfort.
Self-sustaining smoldering as a novel disposal approach for food waste with high moisture content
(2021)
This work aims to explore the self-sustaining smoldering treatment (SSST) for the destruction of food waste. The food waste used in this work mainly consists of cereal, vegetable, and meat. To examine the processing procedures and parameters, three experimental groups (raw food waste, food-waste paste and food-waste paste blended with anthracite) and five variables (moisture content, sand size, sand-to-food waste ratio, air flow and food waste-to-coal ratio) were extensively investigated. Results show that raw food waste with 40% moisture content can be disposed by SSST with the mass destruction ratio over 90%. However, the robustness of SSST for raw food waste is constrained by the heterogeneous issue due to a variety of components and sizes of food waste. This issue is addressed through stir pre-processing of raw food waste as food-waste paste. The robustness of SSST for food waste is significantly further enhanced only if a slight mass fraction of anthracite (<20% of raw food waste) is supplemented. This provides an alternative solution for employing SSST for raw food waste with very high moisture content.
Hydrogen leakage of vehicles in the tunnel is a great threat to the safety operation of the tunnel and longitudinal ventilation strategies have always been utilized to control the fire and smoke movement of rail transit, electric and fossil-fueled vehicles in the engineering field. It is in doubt whether the longitudinal ventilation strategy could still help to reduce the jet fire hazard of transportation with H2 power in the tunnel, considering the rapid development of the hydrogen energy. In present work, a numerical research on effects of longitudinal ventilation strategies on hydrogen jet flames in the tunnel is conducted. The results illustrate that longitudinal ventilation could affect the flame characteristics of jet flames greatly in the tunnel. The critical ventilation velocity increases firstly with the increase of hydrogen leakage rates and then changes little after a critical value. The predicted theoretical model of pool fires could well predict the critical ventilation velocity for hydrogen jet fires. With the increase of longitudinal ventilation velocity, maximum ceiling temperatures are decreased greatly. According to the heat releases, jet speeds and ventilation velocities, three kinds of flame bending characteristics of hydrogen jet fire could be observed due to different effects of the inertial force. At last, the stable thermal stratification could also be destroyed by large ventilation velocities but the corresponding ventilation velocity is far larger than the critical ventilation one. With the increase of longitudinal ventilation velocities, the height of thermal layer is reduced firstly and then maintained at a constant value.
A series of experiments were conducted in a 10L closed and vented tube with L/D = 10.0, and effects of initial fuel volume concentration, inert gas dilutions (diluted by N2 and CO2), inert gas–water mist twin fluid medium dilutions (diluted by N2-H2O twin fluid medium, CO2-H2O twin fluid medium) and end boundary conditions on overpressure transients of hydrocarbon fuel–air mixtures explosion were revealed. Results show that the overpressure-time profiles consistent with the dynamic evolution law of ‘approximately zero-1st overpressure rising stage-2nd overpressure rising stage-descending stage’, and ‘rate of overpressure rise-time’ curves exhibit the characteristics of multi-stages and multi-peaks, such as (dp/dt)(1,max), (dp/dt)(1,min), (dp/dt)(2,max) and (dp/dt)(2,min). Specifically, as the fuel volume concentration increased, both the maximum overpressures (pmax), and the maximum rates of overpressure rise ((dp/dt)(1,max) and (dp/dt)(2,max)) show a variation trend of increasing firstly and then decreasing, while the corresponding times (tmax, θ(1,max) , θ(2,max)) show a total different variation trend. Moreover, when YCH is lower than 1.88%, the value of (dp/dt)(1,max) is greater than (dp/dt)(2,max), while the value of (dp/dt)(1,max) was less than (dp/dt)(2,max), and when YCH was higher than 1.88%. The addition of N2 and CO2 can obviously inhibit the explosion intensity of hydrocarbon fuel, and the inhibition effect of CO2 is better than that of N2. Due to the synergy inhibition effect of the inert gas and ultrafine water mist, all the values of pmax, (dp/dt)(1,max) and (dp/dt)(2,max) diluted by inert gas-ultrafine water mist twin fluid medium were smaller than those diluted by sole inert gases. In addition, there are significant differences in the overpressure-time and the rate of overpressure rise-time profiles between closed and end venting explosions. The values of maximum overpressure and the rates of overpressure rise of the closed explosion were higher than those of the venting explosion, but the minimum rate of overpressure rise is a smaller one.
Safety concerns on cable tray fires in urban utility tunnels, which may further trigger huge casualties, ceiling structure damages, power failures and other domino effects, attract increasing attention in recent years. Determining the maximum excess ceiling gas temperature (MECT) induced by cable tray fires in urban utility tunnels is crucial to evaluate the fire risks. A series of one-layer horizontal cable tray fire experiments to explore the MECT were carried out in a large-scale utility tunnel without mechanical ventilations. The number of cables on the tray was varied from 8 to 18 in the experiments. The experimental results showed that the cable tray fire burning could be divided into three distinct stages, including ignition, self-sustaining and decaying stages. In the self-sustaining combustion stage, the cable tray was found to burn relatively steady. The mean MECT was also investigated since it represents one of the main characteristics of the cable tray fire. By redefining two parameters (the heat release rate and the effective ceiling height) in three classical MECT models proposed originally based on pool-fire, these three models could be extended to be able to predict the mean MECT generated from the cable tray fire (solid combustible) within 20% deviations. Consequently, two novel models were respectively proposed to predict the mean MECT at the self-sustaining burning period and the instantaneous MECT of one-layer horizontal cable tray fire in utility tunnel, which would be useful in the field of fire protection engineering.
Minimum ignition temperature of dust clouds (MITC) was studied experimentally and theoretically in different atmospheres. Three carbonaceous dusts were tested in both air and O2/CO2 atmospheres with CH4 mole fraction from 0 to 2%. Results showed that the ignition risk of the three dusts significantly increases (decrease of MITC by ~100 ℃) with increasing XO2 from 21% to 50%, but significantly decreases replacing N2 in air with CO2. The inhibition effect of CO2 on MITCs could be diminished by increasing XO2 or adding CH4. The addition of small amount of CH4 has different effects on the MITCs of different dust samples, following the opposite order of volatile matter content: anthracite>bituminous coal>starch. Two modified steady-state ignition models, considering the density of mixture gas and dust cloud, XO2 and its diffusivity, were developed to interpret the experimental observations. The analysis revealed that the global heterogeneous ignition model suits well for the hybrid mixtures of anthracite or bituminous coal dusts. In contrast, the proposed global homogeneous ignition model was found to be only valid for the pure starch dust, and the extra CH4 addition could strongly affect the ignition process of starch, particularly in O2/CO2 atmospheres with higher XO2.
The explosion characteristics of anthracite coal dust with/without small amount of CH4 (1.14 vol %) were investigated by using a 20 L spherical explosion apparatus with an emphasis on the roles of oxygen mole fraction and inert gas. Two methods based on overpressure and combustion duration time were used to determine the minimum explosion concentration (MEC) or the lower explosion limit (LEL) of the pure anthracite coal dust and the hybrid coal-methane mixtures, respectively. The experiment results showed that increasing oxygen mole fraction increases the explosion risk of coal dust: with increasing oxygen mole fraction, the explosion pressure (Pex) and the rate of explosion pressure rise ((dp/dt)ex)) increase, while MEC decreases. The explosion risk of anthracite dust was found to be lower after replacing N2 with CO2, suggesting that CO2 has a better inhibition effect on explosion mainly due to its higher specific heat. However, the addition of 1.14% CH4 moderates the inhibition effect of CO2 and the promotion effect of O2 on anthracite dust explosion for some extent, increasing explosion severity and reducing the MEC of anthracite dust. For hybrid anthracite/CH4 mixture explosions, Barknecht’s curve was found to be more accurate and conservative than Chatelier’s line, but neither are sufficient from the safety considerations. The experimental results provide a certain help for the explosion prevention and suppression in carbonaceous dust industries.
The data center needs more and more electricity due to the explosive growth of IT servers and it could cause electricity power shortage and huge carbon emission. It is an attractive and promising solution to power the data center with hydrogen energy source. The present work aims to conduct an economic analysis on the hydrogen-powered data center. Configurations of hydrogen-powered and traditional data centers are compared and the differences focus on backup power system, converter/inverter, fuel cell subsystem, carbon emission, hydrogen and electricity consumptions. Economic analysis is conducted to evaluate the feasibility to power the data center with hydrogen energy source. Results show that electricity price increasing rate and hydrogen cost are the main factors to influence economic feasibility of hydrogen-powered data center. When the electricity price keeps constant in the coming two decades, the critical hydrogen price is about 2.8 U.S. dollar per kilogram. If the electricity price could increase 5% annually due to explosive growth of electric vehicles and economy, critical hydrogen price will become 6.4 U.S. dollar per kilogram. Hydrogen sources and transportation determine the hydrogen price together. Hydrogen production cost varies greatly with hydrogen sources and production technologies. Hydrogen transport cost is greatly influenced by distances and H2 consumptions to consumers. It could be summarized that the hydrogen-powered data center is economic if hydrogen could be produced from natural gas or H2-rich industrial waste streams in chemical plant and data center could not be built too far away from hydrogen sources. In addition, large-scale hydrogen-powered data center is more likely to be economic. Solar hydrogen powered data center has entered into a critical stage in the economic feasibility. Solar hydrogen production cost has restrained the H2 utilization in data center power systems now, since it could be competitive only when more strict carbon emission regulation is employed, hydrogen production cost reduces greatly and electricity price is increasing greatly in the future. However, it could be expected solar hydrogen-powered system will be adopted as the power source of data centers in the next few years.