Dyke breaks - caused by e.g. Overflows or Slop breaks during long lasting high water gauge - Play a great role in a failure potential of extreme flood Events.
Using conventional dyke condition Monitoring dyke messengers can undertake only a visual surface inspection. Thus defective Areas can oftentimes be discovered too late.
A critical area in which failures due to soil displacement and moisture Penetration become more significant is located at a landside dyke foot. Geotextiles are integrated here as a Drainage in case of modern three-zone type of dyke.
In this work, we present our results achieved in several research activities for development of fiber optic dosimeters. The findings show that both the measurement of the radiation-induced attenuation (RIA) along the entire sensing fiber and the accom panying change in the refractive index of the fiber core can be used for distributed radiation monitoring in the kGy and MGy range, respectively. Depending on the fiber type and material the RIA shows varying response to dose rates, environmental temperatures and the wavelength of the laser source used.
In der vorliegenden Studie wurde der Einfluss der statischen Verkehrsbelastung auf die geringen Durchbiegungseffekte in der Betonkonstruktion einer bestehenden Brücke mittels ortsauflösender faseroptischer Sensoren untersucht. Dabei tragen die Ergebnisse der an der Amsterdamer Brücke 705 durchgeführten Belastungstests wesentlich zum Verständnis des Strukturverhaltens bei. Das Konzept der statischen Belastung basierte auf dem Einsatz von zwei 36-Tonnen-Lastwagen, die an mehreren vorbestimmten Stellen auf der Brücke anhielten. Die auf diese Weise aufgebrachte Last führte zu ortsabhängigen kleinen Durchbiegungseffekten, die als lokale Längsdehnung der an der Unterseite der Brücke integrierten Sensorfaser aufgezeichnet wurden. Die reflektometrischen Messungen beruhten auf dem Prinzip genannt TW-COTDR (Tunable Wavelength Coherent Optical Time Domain Reflectometry). Die Messgenauigkeit lag im Bereich von 0,5 µm/m.
We have studied the influence of gamma rays on physical properties of different commercially available silica optical fibers stepwise irradiated up to a total dose of 100 kGy. The detection of radiation-induced changes in silica glass offers the possibility of using selected optical fibers as distributed radiation sensors. The measurements performed by us were based on optical backscatter reflectometry and Brillouin distributed sensing. The measurement methods enable an analysis of radiation-induced modification of the group refractive index and density of the optical fibers. The most distinct physical effect observed by us concerns the increase of the optical attenuation with rising total radiation doses. Quantitative measurement results indicate a crucial impact of fiber dopants on radiation-induced physical and sensory characteristics of silica optical fibers affected by differences in fiber fabrication techniques. Based on the obtained results, the suitability of distributed Brillouin sensing for dosimetry applications seems to be improved by modifying the refractive index profile of the fiber core.
Auf der Grundlage der in DIN EN 61757-2-2:2017 beschriebenen Standardisierungsmethoden wurden in dieser Arbeit wichtige Leistungsparameter von vier kommerziellen Messsystemen zur ortsaufgelösten faseroptischen Erfassung der temperatur- und dehnungsabhängigen Brillouin-Frequenzverschiebung untersucht. Gemäß der oben genannten Norm konzentrierte sich hier die Ermittlungsprüfung auf messtechnische Aspekte reiner Temperaturmessungen. Dabei diente die Ermittlung von einem festgelegten Satz dreier Betriebsverhaltenskenngrößen in Form von quantitativen Angaben des Messfehlers, der Wiederholgenauigkeit sowie der räumlichen Unsicherheit einem Vergleich der getesteten Messsysteme.
Alle faseroptischen Messungen wurden mit einer Faserschleife ausgeführt, d. h. als Sensorkonfiguration der Messfaser wurde eine Schleifenanordnung gewählt. Die Messverfahren der getesteten Messysteme basierten somit auf der Brillouin-optischen Zeit- bzw. Frequenzbereichsanalyse. Die Betriebsverhaltenskenngrößen wurden ferner bei unterschiedlichen Werten zweier messtechnischer Parameter, des Frequenzschrittes und der Mittelungsrate, für Standardeinstellungen der Laserleistungswerte der in die Sensorfaser einzukoppelnden Laserlichtsignale ermittelt. Auf diesem Weg lassen sich relevante Aussagen zur Optimierung der Messgenauigkeiten in Bezug auf Messdauer treffen.